0.6/1KV ABC cable duplex,triplex,quadruplex service drop ,XLPE insulated aluminium 4core conductor overhead Aerial Bundled Cable
Â
Service drop cable meets or exceeds the following specifications:
l  ASTM B-230 Aluminum Wire ,1350-H19 for Electrical Purposes.
l  ASTM B-231  Aluminum Conductors, Concentric-Lay-Stranded.
l  ASTM B-232 Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
l  ASTM B-399  Concentric-Lay-Stranded 6201-T81 Conductors
l  ASTM B-901  Compressed Round Stranded Aluminum Conductors Using Single Input Wire..
Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Code word: Clydesdate,,Pinto,Mustang,Criollo,Percheron,Hanoverian,Oldenburg,Lippizaner,Morochuca,Chola,Morgan,Hackney,
Palomino,Costena,Grullo,Suffolk,Appaloosa,Bronco,gelding,Bay,French Coach,German Coach,Arabian,Belgian,Shetland,
Thoroughbred,Trotter,Walking.
Âspecification:
1. 0.6/1KV
2. Conductor: Pure annealed copper or aluminum
3. Insulation: XLPE/PE/PVC
4. Cores: 1 C, 2C, 3C, 4C
5. Nominal Cross-section: 10mm2 to 400mm2
6. Standard:Â ASTM
7. Max. Operating Temperature: XLPE/PE: 90 °C , PVC : 70 °C .
8. Type: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q
9.Packing: Wooden Drum or according to the customer requirement
10.Remark: The cable can be of flame retardant, fire resistance and other property
Â
Application:
For single core PVC or XLPE insulated or covered aerial cable without messenger or neutral conductor,
the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core PVC or XLPE insulated 11kv abc cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with PVC insulation,and the messenger or neutral conductor is AAAC or ACSR with or without PVC(XLPE) insulation.
permissible continuous operating temperature of conductor: 90oC(XLPE insulated), 70 oC (PE insulated), 70 oC (PVC insulated);Â temperature of conductor during short-circuit ( 5s max. duration) shall not exceed: 250oC(XLPE insulated), 130 oC (PE insulated), 160 oC (PVC insulated);Â
After-Sales Service:
We can provide cable fixation, installation and testing suggestion and help if customer need. if big project problem,technicians can be sent to give instructions to the customers.
Â
Sample Charge:  When you place order for fire resistant cable , the sample fee can be returned to you as support.
Â
Our Services:Our company has been carrying out  CCC,CE,CB , ISO ,OHSAS for flame retardant cables and fire resistant cables in domestic market, for global market we strictly do in accordance with AS/NZS3013 and other corresponding standards. OEM cables are welcomed also.
Â
       3.Product Description:
Â
                    Type |                                                        Description |
JKYJ(F) Â |
             Copper core Irradiated XLPE Insulation Aerial power cable |
JKLYJ(F) |
           Aluminum Core Irradiated XLPE Insulation Aerial Power Cable |
JKLHYJ(F) |
            Aluminum Alloy Core Irradiated XLPE Insulation Aerial Power Cable |
JKLYJ(F)/Q |
           Aluminum Core Light Irradiated XLPE Insulation Aerial Power Cable |
JKLHYJ(F)/Q |
    Aluminum Alloy Core Light Irradiated XLPE Insulation Aerial Power Cable |
Code word |
AWG or kcmil |
Bare Neutral Messenger |
Phase Conductor |
Weight kg/km |
Allowable Ampacities(A) |
|||||
AAC |
Rated Strength lbs. |
AAC |
Insul. Thick. mm |
XLPE |
PE |
|||||
No. |
Dia. mm |
No. |
Dia. mm |
|||||||
Clydesdate Pinto Mustang Criollo Percheron Hanoverian Oldenburg Lippizaner |
3*4AWG+1*4AWG 3*4AWG+1*4AWG 3*2AWG+1*2AWG 3*1/0AWG+1*1/0AWG 3*2/0AWG+1*2/0AWG 3*3/0AWG+1*3/0AWG 3*4/0AWG+1*4/0AWG 3*336.4+1*336.4 |
7 7 7 7 7 19 19 19 |
1.96 1.96 2.47 3.12 3.50 2.39 3.25 3.38 |
881 881 1350 1990 2510 3310 4020 6146 |
1 7 7 19 19 19 19 19 |
5.19 1.96 2.47 1.89 2.13 2.39 3.25 3.38 |
1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 |
299 306 461 744 914 1127 1995 2236 |
100 100 135 180 205 235 275 370 |
80 80 105 140 160 185 210 280 |
Â
COMPANY PROFILE
Chongqing RonJu Co.,LTD which was established with registered capital of 100,000,000 RMB in 2016 Sited in Xi YOng, an industrialized area in shapingpa,.
Chongqing ron ju co.,ltd integrates innovation, generation and sale of cables on a highly efficient production line. Our product is currently widely embraced in multiple areas ranging from electricity to transportation and even urban modernization, proving its versatility and sustainability.
We specializes in manufacturing all kinds of cables with different voltage power cables, control cables, building wires, aluminum alloy cables, aerial cable and other special cables.
We exported all kinds of cables and wires to America,Europe,Australia,Africa,Asia,and so on.Our company got the certificate for ISO 9001 quality system certificate;ISO14001 environmental management system certificate. All the products produce according to,IEC , GB standard.Besides,We also manufacture products according to customer's requirement.
Our team, young and industrious, is dedicated in advancing product itself and the production technique as well, maintaining the established user base, enlarging it through constantly providing high quality products and impeccable service, which are also the sound ground for our branding in this intensely competing international.
With highly specialized products and constantly generated power, our company, R. J. Cable, establishes its "three-in-one" branding (the brand of entrepreneurs, of enterprises, and of products) and pursues a long-term proceeding. Our marketing is distinct for its market-oriented strategies and immediate responses to volatility. Such qualities significantly fuel a dynamically proceeding company.Â
Our Factory:

Our Certification:

Our Advance Equipment:

Our Production Process:

Our Main Products:

FAQ:Â
Q: Are you trading company or manufacturer?Â
A: We are manufacturer.Â
Q: How long is your delivery time?Â
A: Generally it is 5-10 days if the goods are in stock. Or it is 10-15 days if the goods are not in stock, it is according to quantity.Â
Q: Do you provide samples? Is it free or extra?Â
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.Â
Q: What is your terms of payment?Â
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance, balance before shippment.
Â
Q: What is your MOQ?
A:Generally,we make mass production based on MOQ1000M, But if bulk package is ok for you, we can accpet lower order quantity like 500M.
Q: How about your price?
A:We will do our best to offer a good price for our customers, usually our price is worked out according to the current exchange rate, probable order quantity, most important is your sincerity on cooperation!
Â

please link: www.chinaronju.com
Welcome all the partners to visit us. No matter where you are and when we meet, It's never too late to start our long-lasting and friendly cooperation.
WE ARE YOUR BEST CHOICE.LET'S START OUR BUSINESS.
     Â
  0.6/1KV ABC cable duplex,triplex,quadruplex service drop ,XLPE insulated aluminium 4core conductor overhead Aerial Bundled Cable
Â
Service drop cable meets or exceeds the following specifications:
l  ASTM B-230 Aluminum Wire ,1350-H19 for Electrical Purposes.
l  ASTM B-231  Aluminum Conductors, Concentric-Lay-Stranded.
l  ASTM B-232 Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
l  ASTM B-399  Concentric-Lay-Stranded 6201-T81 Conductors
l  ASTM B-901  Compressed Round Stranded Aluminum Conductors Using Single Input Wire..
Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Code word: Clydesdate,,Pinto,Mustang,Criollo,Percheron,Hanoverian,Oldenburg,Lippizaner,Morochuca,Chola,Morgan,Hackney,
Palomino,Costena,Grullo,Suffolk,Appaloosa,Bronco,gelding,Bay,French Coach,German Coach,Arabian,Belgian,Shetland,
Thoroughbred,Trotter,Walking.
Âspecification:
1. 0.6/1KV
2. Conductor: Pure annealed copper or aluminum
3. Insulation: XLPE/PE/PVC
4. Cores: 1 C, 2C, 3C, 4C
5. Nominal Cross-section: 10mm2 to 400mm2
6. Standard:Â ASTM
7. Max. Operating Temperature: XLPE/PE: 90 °C , PVC : 70 °C .
8. Type: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q
9.Packing: Wooden Drum or according to the customer requirement
10.Remark: The cable can be of flame retardant, fire resistance and other property
Â
Application:
For single core PVC or XLPE insulated or covered aerial cable without messenger or neutral conductor,
the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core PVC or XLPE insulated 11kv abc cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with PVC insulation,and the messenger or neutral conductor is AAAC or ACSR with or without PVC(XLPE) insulation.
permissible continuous operating temperature of conductor: 90oC(XLPE insulated), 70 oC (PE insulated), 70 oC (PVC insulated);Â temperature of conductor during short-circuit ( 5s max. duration) shall not exceed: 250oC(XLPE insulated), 130 oC (PE insulated), 160 oC (PVC insulated);Â
After-Sales Service:
We can provide cable fixation, installation and testing suggestion and help if customer need. if big project problem,technicians can be sent to give instructions to the customers.
Â
Sample Charge:  When you place order for fire resistant cable , the sample fee can be returned to you as support.
Â
Our Services:Our company has been carrying out  CCC,CE,CB , ISO ,OHSAS for flame retardant cables and fire resistant cables in domestic market, for global market we strictly do in accordance with AS/NZS3013 and other corresponding standards. OEM cables are welcomed also.
Â
       3.Product Description:
Â
                    Type |                                                        Description |
JKYJ(F) Â |
             Copper core Irradiated XLPE Insulation Aerial power cable |
JKLYJ(F) |
           Aluminum Core Irradiated XLPE Insulation Aerial Power Cable |
JKLHYJ(F) |
            Aluminum Alloy Core Irradiated XLPE Insulation Aerial Power Cable |
JKLYJ(F)/Q |
           Aluminum Core Light Irradiated XLPE Insulation Aerial Power Cable |
JKLHYJ(F)/Q |
    Aluminum Alloy Core Light Irradiated XLPE Insulation Aerial Power Cable |
Code word |
AWG or kcmil |
Bare Neutral Messenger |
Phase Conductor |
Weight kg/km |
Allowable Ampacities(A) |
|||||
AAC |
Rated Strength lbs. |
AAC |
Insul. Thick. mm |
XLPE |
PE |
|||||
No. |
Dia. mm |
No. |
Dia. mm |
|||||||
Clydesdate Pinto Mustang Criollo Percheron Hanoverian Oldenburg Lippizaner |
3*4AWG+1*4AWG 3*4AWG+1*4AWG 3*2AWG+1*2AWG 3*1/0AWG+1*1/0AWG 3*2/0AWG+1*2/0AWG 3*3/0AWG+1*3/0AWG 3*4/0AWG+1*4/0AWG 3*336.4+1*336.4 |
7 7 7 7 7 19 19 19 |
1.96 1.96 2.47 3.12 3.50 2.39 3.25 3.38 |
881 881 1350 1990 2510 3310 4020 6146 |
1 7 7 19 19 19 19 19 |
5.19 1.96 2.47 1.89 2.13 2.39 3.25 3.38 |
1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 |
299 306 461 744 914 1127 1995 2236 |
100 100 135 180 205 235 275 370 |
80 80 105 140 160 185 210 280 |
Â
COMPANY PROFILE
Chongqing RonJu Co.,LTD which was established with registered capital of 100,000,000 RMB in 2016 Sited in Xi YOng, an industrialized a
The RIMA LFP series lithium battery is made of LiFePO4 cells, the battery has been designed and developed to provide a lighter, higher power and longer life solution to lead acid batteries. LiFePO4 batteries last longer and can produce 10 times the number of cycles than a typical lead acid battery. At only 40% of the weight of the equivalent lead acid battery, our LiFePO4 range is ideal for those applications that need to be lighter and more mobile but deliver the same power.
OREMA POWER CO., LTD. , https://www.oremabattery.com