Model NO.: CZ-1500S
Nature of Wave String: Sine Wave Inverter
Type: DC/AC Inverters
Trademark: shenyang
Transport Package: Carton Packaging
Specification: CZ-1500S
Origin: Shanghai
HS Code: 8504403090
Model NO.: CZ-1500S
Nature of Wave String: Sine Wave Inverter
Type: DC/AC Inverters
Trademark: shenyang
Transport Package: Carton Packaging
Specification: CZ-1500S
Origin: Shanghai
HS Code: 8504403090
Product DescriptionConverts the DC electricity from sources such as batteries or fuel cells to AC electricity. The electricity can be at any required voltage; in particular it can operate AC equipment designed for mains operation, or rectified to produce DC at any desired voltage.
Products Features
1. Input & output fully insolated
2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads
3. Soft start: Smooth start-up of the appliances.
4. Pure sine wave output waveform: Clean power for sensitive loads.
5. AC output identical to, and in some cases better than the power supplied by your utility
6. Cooling fan in the inverter is thermally activated and comes on when the inverters becomes warm, and turns off automatically after the inverter has cooled.
7. Low total harmonic distortion: Below 3%
8. Two LED indicators on the front panel shows the working and failure state.
Protection Function
1. Low voltage alarm & Shutdown
2. Over-voltage protection
3. Overload protection
4. Over-temperature protection
5. Short circuit protection
6. Soft start
7. Auto. Reset after being in protected
8. Grounding protection
Technical Specifications
Â
Model | CZ-1500S | ||||
Input | DC voltage | 12V | 24V | 48V | 110V |
Voltage range | 10-16VDC | 20-33VDC | 40-63VDC | Â 90-130VDC | |
No load current draw | 0.7A | 0.4A | 0.2A | 0.1A | |
Efficiency | > 90% | ||||
DC connection | Cables With Clips or Car Adaptor | ||||
Output | AC voltage | 100/110/120VAC or 220/230/240 VAC | |||
Continuous power | 1500W | ||||
Surge power | 3000W | ||||
Waveform | Pure sine wave | ||||
Frequency | 50Hz or 60Hz | ||||
AC regulation | 3% | ||||
Protection | Low voltage alarm | 10.5DC±0.5V | 21DC±1V |  42VDC±1V | 96VDC±3V |
Low voltage shut down | 10DC±0.5V | 20DC±1V | 40VDC±1V | 90VDC±3V | |
Short circuit | Shut off output automatically | ||||
Over load | Shut off output | ||||
Over voltage shut down | 16±0.5V | 33±1V | 63±1V | 130±3V | |
Over thermal | Shut off output automatically | ||||
Environment | Working temperature |  Between -10ºC and +50ºC | |||
Working humidity | 20%~90%RHÂ | ||||
Storage temperature |  Between -30ºC and +70ºC | ||||
Package | Machine size(mm) | 265*165*85 | |||
Packing size(mm) | 365*230*148 | ||||
Net weight(kg) | 2.5 | ||||
Gross weight(kg) | 3 | ||||
Packing mode | Carton packaging | ||||
Other | Start | Soft start | |||
Cooling ways | Intelligent cooling fan |





 Product Description
Converts the DC electricity from sources such as batteries or fuel cells to AC electricity. The electricity can be at any required voltage; in particular it can operate AC equipment designed for mains operation, or rectified to produce DC at any desired voltage.
Products Features
1. Input & output fully insolated
2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads
3. Soft start: Smooth start-up of the appliances.
4. Pure sine wave output waveform: Clean power for sensitive loads.
5. AC output identical to, and in some cases better than the power supplied by your utility
6. Cooling fan in the inverter is thermally activated and comes on when the inverters becomes warm, and turns off automatically after the inverter has cooled.
7. Low total harmonic distortion: Below 3%
8. Two LED indicators on the front panel shows the working and failure state.
Protection Function
1. Low voltage alarm & Shutdown
2. Over-voltage protection
3. Overload protection
4. Over-temperature protection
5. Short circuit protection
6. Soft start
7. Auto. Reset after being in protected
8. Grounding protection
Technical Specifications
Â
Model | CZ-1500S | ||||
Input | DC voltage | 12V | 24V | 48V | 110V |
Voltage range | 10-16VDC | 20-33VDC | 40-63VDC | Â 90-130VDC | |
No load current draw | 0.7A | 0.4A | 0.2A | 0.1A | |
Efficiency | > 90% | ||||
DC connection | Cables With Clips or Car Adaptor | ||||
Output | AC voltage | 100/110/120VAC or 220/230/240 VAC | |||
Continuous power | 1500W | ||||
Surge power | 3000W | ||||
Waveform | Pure sine wave | ||||
Frequency | 50Hz or 60Hz | ||||
AC regulation | 3% | ||||
Protection | Low voltage alarm | 10.5DC±0.5V | 21DC±1V |  42VDC±1V | 96VDC±3V |
Low voltage shut down | 10DC±0.5V | 20DC±1V | 40VDC±1V | 90VDC±3V | |
Short circuit | Shut off output automatically | ||||
Over load | Shut off output | ||||
Over voltage shut down | 16±0.5V | 33±1V | 63±1V | 130±3V | |
Over thermal | Shut off output automatically | ||||
Environment | Working temperature |  Between -10ºC and +50ºC | |||
Working humidity | 20%~90%RHÂ | ||||
Storage temperature |  Between -30ºC and +70ºC | ||||
Package | Machine size(mm) | 265*165*85 | |||
Packing size(mm) | 365*230*148 | ||||
Net weight(kg) | 2.5 | ||||
Gross weight(kg) | 3 | ||||
Packing mode | Carton packaging | ||||
Other | Start | Soft start | |||
Cooling ways | Intelligent cooling fan |





Â
Others Washing Machine Motor,Drain Motor Washing Machine,Washing Machine Dryer Motor,Inverter Motor Washing Machine
WUJIANG JINLONG ELECTRIC APPLIANCE CO., LTD , https://www.jinlongmotor.com