- Model NO.: power cable
- Voltage: Low and Medium Voltage Cable
- Insulation Material: XLPE
- Material Shape: Round Wire
- Certification: ISO, CCC
- Brand: Huatong
- Insulation: XLPE
- Trademark: Huatong
- Specification: copper
- HS Code: 8544492100
- Application: Construction, Underground, Industrial, Power Station
- Current: DC & AC
- Sheath Material: PVC
- Wire Core Material: Red Copper Wire
- Model: YJV
- Conductor: Copper
- Sheath: PVC
- Transport Package: Wooden Drums
- Origin: China
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE power cable has high electric strength, mechanical strength, high-ageing resisting, environmental stress resisting anti-chemical corrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
The flame-retardant and non-flame retardant XLPE cable can be manufactured with three technologies (peroxide, silane and irradiation cross-linking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke non-halogenated and three classes of A,B,C.
Â
Product Description:
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 6/10kV 8.7/15kV 26/35kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core(Single core),two cores(Double cores),three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: IEC 60502. IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
Â
Application conditions
1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.
Â
Â
 XLPE power cable specifications
Â
|
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 | |||
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | ||||
1 Core | Â | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |||
2 Core | Â | 1.5-185 | 25-185 | Â | Â | Â | Â | Â | Â | |||
3 Core | Â | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |||
4 Core | Â | 2.5-400 | 25-400 | Â | Â | Â | Â | Â | Â | |||
5 Core | Â | 2.5-400 | 25-400 | Â | Â | Â | Â | Â | Â |
Â
Type | Name | Main Application | |
Cu Core | Al Core | ||
YJV YJY |
YJLV YJLV |
XLPE insulated,PVC or PE Sheathed Power Cable | For laying indoor,tunnel,channel and undergroud,Unable to bear external mechanical force,but bear the traction force during laid |
YJV22 YJV22 |
YJLV22 YJV22 |
XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable | For laying indoor,tunnel,channel and undergroud Able to bear external mechanical force,but unable to bear large pulling force |
YJV32 YJV32 |
YJLV32 YJLV32 |
XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable | For laying in shaft with large difference of level.Able to bear external machanical force and maderate pulling force |
YJV42 YJV42 |
YJLV42 YJLV42 |
XLPE Insulated,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable | Able to bear positive pressure and pulling force |



High Quality Tablet Ram 4GB/8GB/16GB SODIMM UDIMM DDR4 8gb Laptop 2400mhz Ram
Model
DDR4 SODIMM
Brand
Semsotai /OEM /ODM /OBM
ECC
Non-ECC
Capacity
4GB/8GB/16GB
Chipsets
Samsung /SK Hynix/Mircon/Spec tek
Frequency
2133MHz/2400MHz/2666MHz/3200MHz
Speed
PC4-17000/PC4-19200/PC4-21300/PC4-25600
Componets Configuration
(256m/512m/1G) x8/x16
Memory CAS Lantency
CL15/CL17/CL19/CL21/CL22
Supply Voltage
1.2V
Pin Count
260PIN
PCB layer
8 /10 layer high speed PCB
Certificate
CE/FCC/ROHS
Operation temperature
0C-95C
Compability
100% Work with all motherboard
Ddr4 Laptop Memory,Ddr4 Rgb Ram,Ddr3 Ram 8Gb Pc 1600,Game Ddr3 8Gb
MICROBITS TECHNOLOGY LIMITED , https://www.microbitstrade.com