Model NO.: Solar Cable,Photovoltaic Wire,Type PV Cables,PV1-F
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, UL, RoHS
Brand: Rneda
Model No: PV1-F, Photovoltaic Wire, Type PV Cables
Test Voltage: 6500V;50Hz
Ambient Temperature: -40 Centigrade up to 90 Centigrade
Smoke Emission: IEC 61034;En50268-2
Fire-Resistance Performance: IEC 60332-1
Approvals: TUV 2pfg 1169/0.8. 2007 PV1-F, UL 4703 Type PV Cables
Rated Voltage: 600/1000 V AC/ 1000/1800V DC
Rated Voltage UL: 600V, 1000V, 2000V
RoHS: Yes
Trademark: RNEDA
Transport Package: Roll, Reel, Coil as Your Requirements
Specification: 14AWG TO 1000MCM, 1.5MM2, 2.5MM2, 4MM2, 6MM2
Origin: China
HS Code: 8544492100
Model NO.: Solar Cable,Photovoltaic Wire,Type PV Cables,PV1-F
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, UL, RoHS
Brand: Rneda
Model No: PV1-F, Photovoltaic Wire, Type PV Cables
Test Voltage: 6500V;50Hz
Ambient Temperature: -40 Centigrade up to 90 Centigrade
Smoke Emission: IEC 61034;En50268-2
Fire-Resistance Performance: IEC 60332-1
Approvals: TUV 2pfg 1169/0.8. 2007 PV1-F, UL 4703 Type PV Cables
Rated Voltage: 600/1000 V AC/ 1000/1800V DC
Rated Voltage UL: 600V, 1000V, 2000V
RoHS: Yes
Trademark: RNEDA
Transport Package: Roll, Reel, Coil as Your Requirements
Specification: 14AWG TO 1000MCM, 1.5MM2, 2.5MM2, 4MM2, 6MM2
Origin: China
HS Code: 8544492100
 
2kv Aluminum Photovoltaic Wire, Solar PV Al Cable
Â
APPLICATION
 PV Cable Pvf1-F 1169 PV solar cable

Insulation: ROHS thermosetting insulation material,prior color black or as customer's request.
Sheath: LSZH&UV-resistant electron-beam cross-linked thermosetting Polyolefin copolymer ROHS material,prior color black or as customer's request
1.Nominal Voltage:U0/U=600/1000V AC, 1000/1800V DC ;
2.Test Voltage:6500V,50Hz,5Min. Â
3.Temperature Rating:45oC upto+125oC, -40oF upto+257oF, Ambient temperature:25years(TUV) -40oC Â upto+90oC, -40oF upto+194oF, Max.Short circuit temperature:280oC, +536oF.
5.Bending Radius:Fixed installation>4XÂ Â Occasionally moved>5X
Construction | Conductor construction. | Conductor | Outer | Resistance Max. | Current Carring Capacity | ||||
nxmm2 | n/m | mm | mm | Ω/Km | A | ||||
1X1.5 | 30/0.25 | 1.58 | 4.9 | 13.3 | 30 | ||||
1x2.5 | 50/0.25 | 2.02 | 5.45 | 7.98 | 41 | ||||
1x4 | 56/0.3 | 2.3 | 6.1 | 4.75 | 55 | ||||
1x6 | 84/0.3 | 3.42 | 7.2 | 3.39 | 70 | ||||
1x10.0 | 142/0.3 | 4.56 | 9 | 1.95 | 98 | ||||
1x16.0 | 228/0.3 | 5.6 | 10.2 | 1.24 | 132 | ||||
1x25.0 | 361/0.3 | 6.95 | 12 | 0.795 | 176 | ||||
1x35.0 | 525/0.3 | 8.74 | 13.8 | 0.565 | 218 | ||||
1x50.0 | 720/0.3 | 9.2 | 14.8 | 0.393 | 280 | ||||
1x70.0 | 988/0.3 | 11 | 16.9 | 0.277 | 350 | ||||
 1x95.0 | 1349/0.3 | 12.5 | 18.7 | 0.21 | 410 | ||||
1x120.0 | 1691/0.3 | 14.2 | 20.7 | 0.164 | 480 |
Â

Applications
Single conductor, sunlight-resistant, photovoltaic wire rated 90°C wet or 105°C dry 2000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70
Construction
Conductor: 8 AWG thru 1000 kcmil compact aluminum (8000 series)
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black
Options:
Colored phase ID stripes available on request
Multi-plexing available on request
Features:
Rated 90°C wet and dry
Deformation-resistant at high temperatures
Excellent moisture resistance, exceeds UL 44
Stable electrical properties over a broad temperature range
Excellent resistance to crush and compression cuts
Resistant to most oils and chemicals
UV/sunlight-resistant
Meets cold bend test at -40°C
Specifications
ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers
ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction
StandardÂ
UL 4703 Type PV
National Electrical Code (NEC)
ICEA S-95-658/NEMA WC70
UL 44 Type RHH or RHW-2
UL 854 Type USE-2
c(UL) RWU90 1kV
For sizes less than 1/0: UL 1581 VW-1
For sizes 1/0 and larger: IEEE 383, IEEE 1202/CSA FT4
Â
Size | Diameter of conductor | Min. Number of Strands |
Insulation Thickness |
Nominal O.D. | Net Weight | Maximum conductor resistance at temperature 20ºC |
AWG or kcmil | mm | n | mm | mm | kg/km | Ω/km |
12 | 2.16 | 7 | 1.90 | 6.0 | 46 | 8.880 |
10 | 2.72 | 7 | 1.90 | 6.5 | 56 | 5.590 |
8 | 3.40 | 7 | 2.15 | 7.7 | 80 | 3.520 |
6 | 4.29 | 7 | 2.15 | 8.6 | 102 | 2.210 |
4 | 5.41 | 7 | 2.15 | 9.7 | 135 | 1.390 |
3 | 6.02 | 7 | 2.15 | 10.3 | 156 | 1.100 |
2 | 6.81 | 7 | 2.15 | 11.1 | 183 | 0.875 |
1 | 7.59 | 18 | 2.66 | 12.9 | 244 | 0.693 |
1/0 | 8.53 | 18 | 2.66 | 13.9 | 286 | 0.550 |
2/0 | 9.55 | 18 | 2.66 | 14.9 | 337 | 0.436 |
3/0 | 10.74 | 18 | 2.66 | 16.1 | 400 | 0.346 |
4/0 | 12.07 | 18 | 2.66 | 17.4 | 477 | 0.274 |
250 | 13.21 | 35 | 3.04 | 19.3 | 579 | 0.232 |
300 | 14.48 | 35 | 3.04 | 20.6 | 665 | 0.194 |
350 | 15.65 | 35 | 3.04 | 21.7 | 750 | 0.166 |
400 | 16.74 | 35 | 3.04 | 22.8 | 836 | 0.145 |
450 | 17.78 | 35 | 3.04 | 23.9 | 914 | 0.129 |
500 | 18.69 | 35 | 3.04 | 24.8 | 1028 | 0.116 |
550 | 19.69 | 58 | 3.43 | 26.6 | 1133 | 0.1060 |
600 | 20.65 | 58 | 3.43 | 27.5 | 1217 | 0.0967 |
650 | 21.46 | 58 | 3.43 | 28.3 | 1298 | 0.0893 |
700 | 22.28 | 58 | 3.43 | 29.1 | 1382 | 0.0829 |
750 | 23.06 | 58 | 3.43 | 29.9 | 1463 | 0.0774 |
800 | 23.83 | 58 | 3.43 | 30.7 | 1543 | 0.0725 |
900 | 25.37 | 58 | 3.43 | 32.2 | 1707 | 0.0645 |
1000 | 26.92 | 58 | 3.43 | 33.8 | 1871 | 0.0580 |
Â
 UL Certificate for PV Cable 35KV URD Cable(MV90/105)Â
SOOW CORDS, XHHW,SER,SEU,MC Cable
SOOW CORDS, XHHW,SER,SEU,MC Cable
Â

Â
COMPANY INFORMATIONHebei Huatong Wires and Cables Group Co., Ltd.It was established in 1993.
Hebei Huatong Wires and Cables Group Co., Ltd covers an area more than 220,000 square meters, owning more than 420 sets manufacturing equipment and more than 250 sets of testing equipment or apparatus. Our annual production capacity is 3 billionYuan.Now there are more than 1000 employers in our company, among which more than 150 are technicians.
TWO FACTORIES IN CHINA ! ONE FACTORY IN Tanzania!
Yearly Export Amount 200Millon
Yearly Export Amount 200Millon
Our products are widely used in the field of electric power, coal, metallurgy, petrochemical industry, railway, national defense, construction, aviation and other national key projects.
We are top cable manufacture of rubber serious cables . Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC power cables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We are OEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.

UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD'S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS
Certificates and"National Industrial Production License", "Certificate of Recommended Enterprises and Products for National Grid", "Adopting International Standard Certificate", and "High-Tech Enterprise Certificate", "Certificate of High Quality Products", "Certificate of Scientific and Technological Achievements", "Qualified Supplier Certificate", "China Classification Society Certificate of Works Approval", "Det Norske Veritas Type Approval Certificate", "Railway Product Certificate", "Safety Certificate of Approval for Mining Products", "National Mandatory Product Certification", "Certificate for China Compulsary Products Certification" and "Practical New-Type Patent Certificate".
Our Service
1.24years production experience and 15 years export experience .
2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback  Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7. Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
FAQ
1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgentto get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
 Â
High-speed Transmission Lines
High-Speed Transmission Lines,Micro B Charger Cable,Mini Usb Cable,High Speed Printer Line
ShenZhen Puchen Electronics Co., Ltd. , https://www.szpuchen.com