 600V SOOW Flexible Portable Cord,SOOW Cables,
14/3 SOOW Rubber Flexible Extra Heavy Duty CordÂ

APPLICATION
TYPE SOOW Cable is for use in heavy-duty industrial applications where flexibility and durability is required. SOOW is designed for extra hard usage on industrial equipment, heavy tools, motor and welding leads, power extensions, portable machinery, sound equipment, portable stage lights, marine dockside power and mining applications. Constructed of color-coded synthetic oil, ozone and water resistant rubber (EPDM) insulation and an oil resistant thermoset chlorinated polyethylene (CPE) jacket, SOOW is rated for indoor/outdoor use.
SOOW flexible rubber cords carry a 600 volt rating. They are also manufactured as a 300 volt rated Junior Service cord designated as SJOOW. Using the key, a SJEOOW cord is a 300 volt (junior service) elastomer plastic oil resistant inner and outer jacket portable cord.
Â-
Portable tools
Industrial and processing equipment
Construction equipment
Cranes and hoists
Track systems
Battery chargers
Portable appliances
Small motors and associated machinery
Electrical equipment exposed to oils, solvents, flame, or moisture
STANDARDS & REFERENCES
Type SOOW Cords/Cable meets or exceeds the applicable requirements of the following standards and
specifications:
UL Standard 62 for Flexible Cords
CSA Standard 22.2 No. 49 for Flexible Cords
MSHA flame resistance for mining applications
NEC Article 400
RoHS Compliant
SOOW offers:
   • Excellent resistance to oils, acids, chemicals, water, ozone, extreme
     temperatures, cuts, tears and abrasion
   • Sunlight resistant
   • Flame retardant
   • Indoor/outdoor rated
   • Highly flexible
   • Maximum continuous conductor temperature: 90°C DRY
CONSTRUCTION
Conductors: Bare, annealed copper per ASTM B-3 Flexible, bunch-stranded per UL-62
Separator: A paper tape is applied between the conductor and insulation to facilitate stripping.
Insulation: Color coded synthetic rubber (EPDM) oil and water resistant per UL-62
Jacket: Black Chlorinated Polyethylene (CPE)
Cabling: Conductors are assembled round with fillers as needed.
Temperature Range: -40°C to +90°C
Voltage Rating: 600 Volts for SOOW,300 Volts for SJOOW
Â
Conductor
Size
(AWG)
|
Conductor Stranding |
Nominal Insulation Thickness |
Nominal Jacket Thickness |
Nominal Overall Diameter (in) |
Weight | Ampacity | ||
n | / | AWG/inch | mil | mil | in | lbs/1000ft | A | |
2*18AWG | 16 | / | 30 | 30 | 60 | 0.33 | 70 | 10 |
3*18AWG | 16 | / | 30 | 30 | 60 | 0.35 | 80 | 10 |
4*18AWG | 16 | / | 30 | 30 | 60 | 0.37 | 96 | 7 |
2*16AWG | 26 | / | 30 | 30 | 60 | 0.36 | 86 | 13 |
3*16AWG | 26 | / | 30 | 30 | 60 | 0.37 | 99 | 13 |
4*16AWG | 26 | / | 30 | 30 | 60 | 0.41 | 119 | 10 |
2*14AWG | 41 | / | 30 | 45 | 80 | 0.49 | 155 | 18 |
3*14AWG | 41 | / | 30 | 45 | 80 | 0.51 | 179 | 18 |
4*14AWG | 41 | / | 30 | 45 | 80 | 0.56 | 215 | 15 |
2*12AWG | 65 | / | 30 | 45 | 95 | 0.56 | 206 | 25 |
3*12AWG | 65 | / | 30 | 45 | 95 | 0.58 | 239 | 25 |
4*12AWG | 65 | / | 30 | 45 | 95 | 0.63 | 290 | 20 |
2*10AWG | 104 | / | 30 | 45 | 95 | 0.62 | 266 | 30 |
3*10AWG | 104 | / | 30 | 45 | 95 | 0.66 | 316 | 30 |
4*10AWG | 104 | / | 30 | 45 | 95 | 0.72 | 385 | 25 |
3*8AWG | 133 | / | 29 | 60 | 110 | 0.83 | 505 | 40 |
4*8AWG | 133 | / | 29 | 60 | 125 | 0.93 | 646 | 35 |
5*8AWG | 133 | / | 29 | 60 | 125 | 0.93 | 684 | 35 |
3*6AWG | 133 | / | 27 | 60 | 125 | 0.95 | 694 | 55 |
4*6AWG | 133 | / | 27 | 60 | 140 | 1.07 | 885 | 45 |
5*6AWG | 133 | / | 27 | 60 | 140 | 1.07 | 946 | 45 |
3*4AWG | 133 | / | 0.0177 | 60 | 140 | 1.09 | 952 | 70 |
4*4AWG | 133 | / | 0.0177 | 60 | 155 | 1.22 | 1210 | 60 |
5*4AWG | 133 | / | 0.0177 | 60 | 155 | 1.22 | 1304 | 60 |
3*2AWG | 133 | / | 0.0223 | 60 | 155 | 1.26 | 1344 | 95 |
4*2AWG | 133 | / | 0.0223 | 60 | 170 | 1.41 | 1705 | 80 |
5*2AWG | 133 | / | 0.0223 | 60 | 170 | 1.41 | 1853 | 80 |

UL Certificate for SOOW CORDS, XHHW,SER,SEU,MC Cable
Hebei Huatong Wires and Cables Group Co., Ltd.It was established in 1993.
Hebei Huatong Wires and Cables Group Co., Ltd covers an area more than 220,000 square meters, owning more than 420 sets manufacturing equipment and more than 250 sets of testing equipment or apparatus. Our annual production capacity is 3 billionYuan.Now there are more than 1000 employers in our company, among which more than 150 are technicians.
Yearly Export Amount 200Millon
Our products are widely used in the field of electric power, coal, metallurgy, petrochemical industry, railway, national defense, construction, aviation and other national key projects.
We are top cable manufacture of rubber serious cables . Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC power cables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We are OEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.


Package Picture

Our Service
1.24years production experience and 15 years export experience .
2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback  Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7. Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
FAQ
1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgentto get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Â

 600V SOOW Flexible Portable Cord,SOOW Cables,
14/3 SOOW Rubber Flexible Extra Heavy Duty CordÂ

APPLICATION
TYPE SOOW Cable is for use in heavy-duty industrial applications where flexibility and durability is required. SOOW is designed for extra hard usage on industrial equipment, heavy tools, motor and welding leads, power extensions, portable machinery, sound equipment, portable stage lights, marine dockside power and mining applications. Constructed of color-coded synthetic oil, ozone and water resistant rubber (EPDM) insulation and an oil resistant thermoset chlorinated polyethylene (CPE) jacket, SOOW is rated for indoor/outdoor use.
SOOW flexible rubber cords carry a 600 volt rating. They are also manufactured as a 300 volt rated Junior Service cord designated as SJOOW. Using the key, a SJEOOW cord is a 300 volt (junior service) elastomer plastic oil resistant inner and outer jacket portable cord.
Â-
Portable tools
Industrial and processing equipment
Construction equipment
Cranes and hoists
Track systems
Battery chargers
Portable appliances
Small motors and associated machinery
Electrical equipment exposed to oils, solvents, flame, or moisture
STANDARDS & REFERENCES
Type SOOW Cords/Cable meets or exceeds the applicable requirements of the following standards and
specifications:
UL Standard 62 for Flexible Cords
CSA Standard 22.2 No. 49 for Flexible Cords
MSHA flame resistance for mining applications
NEC Article 400
RoHS Compliant
SOOW offers:
   • Excellent resistance to oils, acids, chemicals, water, ozone, extreme
     temperatures, cuts, tears and abrasion
   • Sunlight resistant
   • Flame retardant
   • Indoor/outdoor rated
   • Highly flexible
   • Maximum continuous conductor temperature: 90°C DRY
CONSTRUCTION
Conductors: Bare, annealed copper per ASTM B-3 Flexible, bunch-stranded per UL-62
Separator: A paper tape is applied between the conductor and insulation to facilitate stripping.
Insulation: Color coded synthetic rubber (EPDM) oil and water resistant per UL-62
Jacket: Black Chlorinated Polyethylene (CPE)
Cabling: Conductors are assembled round with fillers as needed.
Temperature Range: -40°C to +90°C
Voltage Rating: 600 Volts for SOOW,300 Volts for SJOOW
Â
Conductor
Size
(AWG)
|
Conductor Stranding |
Nominal Insulation Thickness |
Nominal Jacket Thickness |
Nominal Overall Diameter (in) |
Weight | Ampacity | ||
n | / | AWG/inch | mil | mil | in | lbs/1000ft | A | |
2*18AWG | 16 | / | 30 | 30 | 60 | 0.33 | 70 | 10 |
3*18AWG | 16 | / | 30 | 30 | 60 | 0.35 | 80 | 10 |
4*18AWG | 16 | / | 30 | 30 | 60 | 0.37 | 96 | 7 |