Height | 6m to 30m or other height customer requirement |
Suit for | Electric Power Distribution Transmission Steel Tower |
Shape | Conoid ,Multi-pyramidal,Columniform,polygonal or conical |
Material |
Usually Q345B/A572,minimum yield strength>=345n/mm2 Q235B/A36,minimum yield strength>=235n/mm2 As well as Hot rolled coil from Q460 ,ASTM573 GR65, GR50 ,SS400, SS490, to ST52 |
Strength | 2.5KN,5KN,8KN,10KN,12KN |
Torlance of the dimenstion | +- 2%Â |
Optical assembly of lighting fixture | Â Â IP 65 |
Electroshock resistant protective grade | Â Grde I |
The casing anti-corrosion performance | Â Class II |
Working atmosphere of lighting fixture | -35 ºC~+45 ºC |
 Surface treatment |   Hot dip galvanized Following ASTM A 123, color polyester power or any other standard by client required |
Joint of Poles | Â Insert mode,innerflange mode,face to face joint mode |
Design of pole | Â Â Against earthquake of 8Â grade |
  Wind Speed | 160km/hour |
Minimum yield strength | 335mpa |
Minimum ultimate tensile strength | 400mpa |
 Max ultimate tensile strength |  620mpa |
Standard | ISO9001 |
Length of per section | Within 14m once forming without slip joint |
Welding |
We has past flaw testing.Internal and external double welding makes the welding beautiful in shape. Welding Standard :AWS (Â American Welding Society )Â D 1.1 |
 Thickness | 1mm to 30mm |
Packages | Our poles as normal cover by Mat or straw bale at the top and bottom ,anyway also can following by client required , each 40HC or OT can loading how many pcs will calculation base on the client actually specification and data. |
Style | Size and styles are veriable as per customer request  |
Production Process
Raw material test → Cutting →Molding or bending →Welidng (longitudinal )→Dimension verify
→Flange welding →Hole drilling →Calibration → Deburr→Galvanization or powder coating ,painting →Recalibration →Thread →Packages
![]() |
![]() |
 |
![]() |
![]() |
 |
Factory Show
Yangzhou Shixin Landscape Lighting company is located in Tianshan Industrial Park of Yangzhou, which is the largest and best street light manufacture in China. The company is specialized in production of street light, LED street light, solar street light, pole, high mast, garden light, lawn light and so on. We have 189 workers, 20Â technicists, and 25 serve clerks. We have been working in this line from 2004.And we have done many big projects abroad and won good reputation from our customers.

FAQ
1:How many cycles full charge&discharge about your battery?
 In 50% discharging deepness, it can be cycled for 1,200 times; in floating charging and discharging status, it can be cycled for 5000~6000 times.Â
2.How to Choose the System Voltage  12V or 24V or for normal street Light ?Â
We can design the System for 12v or 24v for solar street Light or 220-380V for normal street light . Â
3.What's the main difference between mono and polycrystalline solar panel?
production process and cost. Polysilicon technology is more mature since it is an early technology compared with Monosilicon.Â
4.The controller of your solar street light has dual time control function?
our solar charge controller is designed with dual time control function, you can set up the lighting time and divide it into two parts, like 12 hours (6 hours full power lighting +Â 6 hours half power lighting)
Welcome to contact us a.s.a.p.
Contact person:Dongzhou Zhao | M.B.+8618652772323 |
 | dongzhou.zhao |
 Product Description

Height | 6m to 30m or other height customer requirement |
Suit for | Electric Power Distribution Transmission Steel Tower |
Shape | Conoid ,Multi-pyramidal,Columniform,polygonal or conical |
Material |
Usually Q345B/A572,minimum yield strength>=345n/mm2 Q235B/A36,minimum yield strength>=235n/mm2 As well as Hot rolled coil from Q460 ,ASTM573 GR65, GR50 ,SS400, SS490, to ST52 |
Strength | 2.5KN,5KN,8KN,10KN,12KN |
Torlance of the dimenstion | +- 2%Â |
Optical assembly of lighting fixture | Â Â IP 65 |
Electroshock resistant protective grade | Â Grde I |
The casing anti-corrosion performance | Â Class II |
Working atmosphere of lighting fixture | -35 ºC~+45 ºC |
 Surface treatment |   Hot dip galvanized Following ASTM A 123, color polyester power or any other standard by client required |
Joint of Poles | Â Insert mode,innerflange mode,face to face joint mode |
Design of pole | Â Â Against earthquake of 8Â grade |
  Wind Speed | 160km/hour |
Minimum yield strength | 335mpa |
Minimum ultimate tensile strength | 400mpa |
 Max ultimate tensile strength |  620mpa |
Standard | ISO9001 |
Length of per section | Within 14m once forming without slip joint |
Welding |
We has past flaw testing.Internal and external double welding makes the welding beautiful in shape. Welding Standard :AWS (Â American Welding Society )Â D 1.1 |
 Thickness | 1mm to 30mm |
Packages | Our poles as normal cover by Mat or straw bale at the top and bottom ,anyway also can following by client required , each 40HC or OT can loading how many pcs will calculation base on the client actually specification and data. |
Style | Size and styles are veriable as per customer request  |
Production Process
Raw material test → Cutting →Molding or bending →Welidng (longitudinal )→Dimension verify
→Flange welding →Hole drilling →Calibration → Deburr→Galvanization or powder coating ,painting →Recalibration →Thread →Packages
![]() |
![]() |
 |
![]() |
![]() |
 |
Factory Show
Yangzhou Shixin Landscape Lighting company is located in Tianshan Industrial Park of Yangzhou, which is the largest and best street light manufacture in China. The company is specialized in production of street light, LED street light, solar street light, pole, high mast, garden light, lawn light and so on. We have 189 workers, 20Â technicists, and 25 serve clerks. We have been working in this line from 2004.And we have done many big projects abroad and won good reputation from our customers.

FAQ
1:How many cycles full charge&discharge about your battery?
 In 50% discharging deepness, it can be cycled for 1,200 times; in floating charging and discharging status, it can be cycled for 5000~6000 times.Â
2.How to Choose the System Voltage  12V or 24V or for normal street Light ?Â
We can design the System for 12v or 24v for solar street Light or 220-380V for normal street light . Â
3.What's the main difference between mono and polycrystalline solar panel?
production process and cost. Polysilicon technology is more mature since it is an early technology compared with Monosilicon.Â
4.The controller of your solar street light has dual time control function?
our solar charge controller is designed with dual time control function, you can set up the lighting time and divide it into two parts, like 12 hours (6 hours full power lighting +Â 6 hours half power lighting)
Welcome to contact us a.s.a.p.
Contact person:Dongzhou Zhao | M.B.+8618652772323 |
 | dongzhou.zhao |
Â
Hex bolts made of zinc plated steel or stainless steel,are available in diameter from 6mm to 24mm and ideal for construction and repair.
Tap bolts with hex heads and fully threaded shanks,are extensively used in boat building,exterior woodworking and water treatment areas,etc.
Countersunk bolts,made of grade 4.8 and 8.8 steel,are available with slot,cross and hex holes in their heads and used when a flat surface needed.
Hex Nuts matching with Hex bolts,are made of quality low carbon or stainless steel,are available in standard,heavy type,jam and panel types.we have many kind of Screw bolt nut:carbon steel hex nut,flange nut,stainless steel lock nuts,stainless steel hex nuts(m2-m48),DIN934,DIN439 marks,hex nuts,flange nuts,DIN6923/GB6177,stainless steel and carbon steel lock nuts,length of 20,flange nut m20,hex flange nut,factory stainless steel cage nut with HIGH-reputation in,wing nut DIN315.
1.Material ; caron steel ,Alloy steel ,
2.:Size : M3-M100
3.Color : Black ,Color -plated zinc ,Copper plated ,hot dip galvanized
4. Standard : DIN/ANSI B18.2.1 /JFI/JIS
5 Certificate : ISO9001 : 2008 ISO/TSI6949,2009
6.Specification : Dia M3-M100, length :20mm-300mm
Hex Bolts,Round Head Bolts,Socket Bolts,Flange Bolts,Countersunk Bolts
BAODING JIMAOTONG IMPORT AND EXPORT CO., LTD , https://www.chinagroundscrew.com