Model NO.: BD-TYN187
Input Voltage: 12v
With Light Source: With Light Source
LED Chips Brand: Bridgelux
Light Source: LED Light
Pole: Steel Q235 345 Gr60
Service: 8 Years
Input Volatge: DC 12-24V
Lamp Luminous Efficiency: 120lm / W
Lamp Fixture Material: Aluminum
Trademark: Luyou
Specification: CE, ROHS
Origin: Yangzhou
HS Code: 940540900
Model NO.: BD-TYN187
Input Voltage: 12v
With Light Source: With Light Source
LED Chips Brand: Bridgelux
Light Source: LED Light
Pole: Steel Q235 345 Gr60
Service: 8 Years
Input Volatge: DC 12-24V
Lamp Luminous Efficiency: 120lm / W
Lamp Fixture Material: Aluminum
Trademark: Luyou
Specification: CE, ROHS
Origin: Yangzhou
HS Code: 940540900
About solar street light working principle:
The solar street light relies on solar energy, which is clean, endless and environment-friendly. The system is mainly composed of solar panel, light source, controller and battery.  In daytime, when there is sunshine, the solar panel can convert the solar energy to electric  energy and store it in the battery. At night or rainy or cloudy condition, the battery shall supply power for normal lighting. The controller can judge the brightness of daylight and automatically switch on the light. The whole process is operating in completely automatic mode, without human action. |
Company Information
We Are ManufacturerÂ
Since 1998, we've manufactured solar street light for over 15 years. |
We manufacture main components from LED source, light fixture, solar panel, pole and even  painting powder to control the cost and quality. |
We produce solar LED street light from 5W-100W and pole height from 3M-12M |
We are capable to produce 10,000 LED solar street lights per month |
Product Description
Specifications
Components | Parameters | |
Solar Module | Pmax(W) | 30-400W |
Vmp (V) | 35.0V | |
Imp (A) | 2.86A | |
Light Fixture | Material | Aluminum die casting & Toughened glass |
Operating Temperature | -40°C~75°C | |
Protection Level | IP65 | |
LED Light Source | LED Chip | BRIDGELUX / Cree (Top brand in U.S.A.) |
Color Temperature | 3800-6500K(white) | |
Luminous flux | 5300 LM | |
Operating temperature | -40°C~75°C | |
Current Source | DC 12V/24V | |
Power | 15W/18W/21W/24W/30W/36W/42W/48W/54W/60W | |
Lighting Pole | Height | 3m/ 4m/ 5m/ 6m/ 7m/ 8m/ 9m/ 10m/ 11m/ 12 m |
Material | BAOSTEELÂ GROUPÂ Q235/345/GR60 | |
Surface Treatment | Hot-dip galvanizing, Static spray, | |
Size | φ60-φ200,δ3-5m, vary according to models | |
Flange Plate | 300*300*16, vary according to models | |
Battery | Capacity | 200AHÂ (100AH*2pcs) |
Type | Gel/AGMÂ Battery | |
Dimension | 546*1203*30 | |
Weight | 28Kg | |
Controller | Rated voltage and current | 12V/10A or 24V/10A waterproof |
Weight | 0.165Kg | |
Two times rainy day backup &Protective Function |
Two times of rainy day backup. Good protection: overcharging, discharging, voltage surge, reverse polarity, etc. |
|
Accessories | Cable | 2.5 mm2, 15m |
Battery Box | 200AH ABS battery box or metal box with hot-dip galvanizing spray treatment | |
Foundation Kit | Dismountable foundation kit, saving in shipping |
Solar Street Light Details
Â
A GRADE high efficient solar panel |
Solar panels are made of monocrystalline or polycrystalline silicon solar cells, series connection or parallel connection, then hot-pressed and sealed by tempering glass and EVA,TPT, equipped with aluminum alloy frame, have the characteristic of the wind-resistant, hail resistant and easy installation. The panel is widely used in solar lighting, lamps, household power supply, road transport, building and photovoltaic power station, etc. |
Mono: 18% convert efficiency |
Poly:  17% convert efficiency |
5 years warranty for solar panels |
Â
USA BRAND LED and Aluminum Section Bar Light Fixture brand new model 20-90W LED street light. Features are: |
1. 20W, 30W, 40W, ...90W available (with Bridgelux or CREE LED). |
2. 20-30W beam angle: lateral 120 degree, vertical 60 degree;  |
3. 40-90W beam angle: lateral 140 degree + 20 degree adjustable = 160 degree, vertical 60 degree; |
4. Interpole distance can be 45-55M; |
5. 20W per module by Epistar LED (85lm/W, 3 year warranty),  30W per module by CREE LED; |
6. With CREE LED, 85lm/W or 95lm/W, with the best MEANWELL driver, 5 year warranty; |
7. Pole socket 0 - 115 degree adjustable, so enable both lateral and vertical installation |
8. Back cover can be easily opened, simple maintenance, lower cost. |
9. Each LED module has specially designed lens, making luminance concentracted in a rectangular area, get much higher |
10. Heat sink also uniquely designed, <55°C degree, getting longer working life. |
11. Built-in constant voltage driver in each LED module, making it works much stable and longer time. |
Â
STRONGER POLE with 20 years life time |
Larger diameter: our pole is 10% larger in diameters |
Thicker wall: we offer 0.25mm thicker pole than that of the market. For example, we offer 3mm thickness  for 6m pole, while other, 2.5-2.75mm |
Bigger foundation kits: for example, we offer M18-20*1000mm bolts for 6m light, while others, M16-18*800mm |
Thicker zinc galvanization and painting: we offer 100 μm zinc and coating than the standard 80 μm |
Â
TWO TIMES rainy day backup waterproof controller |
Rainy day backup: 2 times more rainy day backup, savings in battery Combined LED driver and controller  as one, easy to maintain |
IP67: ideal for high humidity and dust areas |
Energy saving mode: THREE periods of power adjustment available |
All metal shell: high strength and fast heat dissipation, giving long life time |
Â
ULÂ LISTEDÂ GELÂ battery |
Gel Battery that dedicated to solar energy. For the solar energy street lamp that in simple circulatory system. the advantage is that the small selfdischarge rate ,the better deep discharge, Top charge acceptance, large capacity,strong start in low ,the good shock resistant and Anti-temperature charge Production |
Size: 483x170x240mm,Weight :44.5KG |
Packing Size :506x193x290mm,Weight :46.4KG |
Applications
Solar Street Light Solar Road Light Solar Path Light Solar Parking Lot Light Solar Driving way Light Solar Highway Light Solar Freeway Light Solar Avenue Light Solar Sidewalk Light Solar Remote Area Light Solar Military Bases Light |
Solar Security Light Solar Garden Light Solar Park Light Solar Gate Light Solar Grave Light Solar Entrance Light Solar Fence Light Solar Campus Light Solar Boat Dock Light Solar Pedestrian Street Light Solar Jogging and Bike Path Light |
Standard Features
- Solar panel: 20 years power generation capacity - LED light: ultra bright LEDs that last up to 50,000 hours - Controller: typical operating life of 10 year, auto ON/OFF operation - Pole: up to 25 years long life time - Battery: long life of up to 5 years |
Certification
Â
  Services
Warranty
BAODE guarantees the purchaser for the period of two (2) years that BAODE's new lighting systems will be free from defects in materials and workmanship. BAODE will, at its option, repair or replace any BAODE's system that is defective for a minimum of two (2) years after the date of purchase. and workmanship. BAODE will, at its option, repair or replace any BAODE's system that is defective for a minimum of two (2) years after the date of purchase. |
Installation
BAODE offers detailed instructions and videos for installation. Besides, BAODE can provide onsite  installation training and technical assistance free of charge in initial period for large projects more than 100 poles because we has developed her experienced technical team. kerning,"and workmanship. BAODE will, at its option, repair or replace any BAODE's system that is  defective for a minimum of two (2) years after the date of purchase. |
After Sales
 BAODE will offer technical guidance and repair service for the whole life time of her products.Â
 BAODE promises to respond with customer's questions within 24 working-hours.
Â
Payment terms: 30% in advance and 70% before shipment.
Lead time: 2~3 weeks upon receipt of payment for 50 poles.Â
Shipping: Generally, solar lights are shipped by sea. Battery and pole are not available to ship by air.
Package: Individual package for each component of solar light. Wooden box for LED lamp and solar panel for LCL goods. 80 poles load a 40 HP container for 8M solar street lights and 60-3.5m solar garden lights in a 20 container.

About solar street light working principle:
The solar street light relies on solar energy, which is clean, endless and environment-friendly. The system is mainly composed of solar panel, light source, controller and battery.  In daytime, when there is sunshine, the solar panel can convert the solar energy to electric  energy and store it in the battery. At night or rainy or cloudy condition, the battery shall supply power for normal lighting. The controller can judge the brightness of daylight and automatically switch on the light. The whole process is operating in completely automatic mode, without human action. |
Company Information
We Are ManufacturerÂ
Since 1998, we've manufactured solar street light for over 15 years. |
We manufacture main components from LED source, light fixture, solar panel, pole and even  painting powder to control the cost and quality. |
We produce solar LED street light from 5W-100W and pole height from 3M-12M |
We are capable to produce 10,000 LED solar street lights per month |
Product Description
Specifications
Components | Parameters | |
Solar Module | Pmax(W) | 30-400W |
Vmp (V) | 35.0V | |
Imp (A) | 2.86A | |
Light Fixture | Material | Aluminum die casting & Toughened glass |
Operating Temperature | -40°C~75°C | |
Protection Level | IP65 | |
LED Light Source | LED Chip | BRIDGELUX / Cree (Top brand in U.S.A.) |
Color Temperature | 3800-6500K(white) | |
Luminous flux | 5300 LM | |
Operating temperature | -40°C~75°C | |
Current Source | DC 12V/24V | |
Power | 15W/18W/21W/24W/30W/36W/42W/48W/54W/60W | |
Lighting Pole | Height |
3m/Â 4m/Â 5m/Â 65V 3A USB Charger 5V 3A Usb Charger,5V3A Wall Charger,5V3A Usb Wall Charger,5V 3A Usb Output Charger Guangdong Mingxin Power Technologies Co.,Ltd. , https://www.mxpowersupply.com |