Product Description
                 G657A ADSS 2/12/24 core Single Mode Flat Optical Cable for Outdoor(GYFXY-3)


Description


 The loose tube are made of high modulus plastics(PBT), which are filled with water resistant gel. Water blocking yarn wrapped which used for waterproof resistance. Two FRP(Kevlar) strength  member provide high tensile resistance. Outer sheath is made of UV resistance PE jacket. All  dielectric cable construction allows hanging on electric poles and power lines with up to 12KV. 


Feature
All-dielectric cable construction
Flat cable, Unitube design. Up to 12fibers.
Suitable for outdoor and indoor usage
Compact structure, small size and light weight.
Water blocking, UV resistance, High and low temperature resistance.
Adopt strict process and raw materials control guarantee the lifespan more than 30 years.
   
Application:
 
For laying inside buildings, in risers, attics, basements, sewers and pipelines.
It's a good choise for last mile FTTX project.
Fiber optic Cable for Aerial


PRODUCTION LINE

PACKAGING


Products Standard

Mechanical Performance:
Max Tension Performance:    IEC 60794-1-2-E
Max. Operation Tension:       IEC 60794-1-2-E1
Crush Test:                          IEC 6079 -1-2-E3
Impact Test:                        IEC 60794-1-2-E4
Repeated Bending:                 IEC 60794-1-2-E6
Torsion Test:                       IEC 60794-1-2-E7
Cable bend:                          IEC 60794-1-2-E11A
Attenuation Coefficient:         ITU-T G. 652
Structural Test:                    IEC-60793-1-20
Environmental Performance
Temperature Cycling:           IEC 60794-1-2-F1
Water Penetration:                IEC 60794-1-2-F5B
Filing Compound Flow:         IEC 60794-1-E14


Technical Parameters

Fiber Count

2-8

10-12

14-24

Diameter of Strengthen member (FRP)

2x1.5mm

Reinforcing material 

Fiber glass yarn/Kevlar yarn

Diameter of Loose tube(mm)

2.1

2.1

As requirement

Diameter of Cable(mm)

5.2*9.3

5.2*9.3

 

Gross weight(Kg/Km)

40

40

 

Min. bending radius

Static 30xD     Dynamic 40xD

Max. tensile force, N

Short term/ Long term   1000N/400N

Max Crush Resistance(N/100mm)

Short term/ Long term   1000N/300N

Allowable Temperatures

operation

-40°C - +60°C

 

storage

-50°C - +70°C

 

install.

-20°C - +50°C

Aerial Flat Fiber Optic Cable
Product Description
                 G657A ADSS 2/12/24 core Single Mode Flat Optical Cable for Outdoor(GYFXY-3)


Description


 The loose tube are made of high modulus plastics(PBT), which are filled with water resistant gel. Water blocking yarn wrapped which used for waterproof resistance. Two FRP(Kevlar) strength  member provide high tensile resistance. Outer sheath is made of UV resistance PE jacket. All  dielectric cable construction allows hanging on electric poles and power lines with up to 12KV. 


Feature
All-dielectric cable construction
Flat cable, Unitube design. Up to 12fibers.
Suitable for outdoor and indoor usage
Compact structure, small size and light weight.
Water blocking, UV resistance, High and low temperature resistance.
Adopt strict process and raw materials control guarantee the lifespan more than 30 years.
   
Application:
 
For laying inside buildings, in risers, attics, basements, sewers and pipelines.
It's a good choise for last mile FTTX project.
Fiber optic Cable for Aerial


PRODUCTION LINE

PACKAGING


Products Standard

Mechanical Performance:
Max Tension Performance:    IEC 60794-1-2-E
Max. Operation Tension:       IEC 60794-1-2-E1
Crush Test:                          IEC 6079 -1-2-E3
Impact Test:                        IEC 60794-1-2-E4
Repeated Bending:                 IEC 60794-1-2-E6
Torsion Test:                       IEC 60794-1-2-E7
Cable bend:                          IEC 60794-1-2-E11A
Attenuation Coefficient:         ITU-T G. 652
Structural Test:                    IEC-60793-1-20
Environmental Performance
Temperature Cycling:           IEC 60794-1-2-F1
Water Penetration:                IEC 60794-1-2-F5B
Filing Compound Flow:         IEC 60794-1-E14


Technical Parameters

Fiber Count

2-8

10-12

14-24

Diameter of Strengthen member (FRP)

2x1.5mm

Reinforcing material 

Fiber glass yarn/Kevlar yarn

Diameter of Loose tube(mm)

2.1

2.1

As requirement

Diameter of Cable(mm)

5.2*9.3

5.2*9.3

 

Gross weight(Kg/Km)

40

40

 

Min. bending radius

Static 30xD     Dynamic 40xD

Max. tensile force, N

Short term/ Long term   1000N/400N

Max Crush Resistance(N/100mm)

Short term/ Long term   1000N/300N

Allowable Temperatures

operation

-40°C - +60°C

 

storage

-50°C - +70°C

 

install.

-20°C - +50°C