PCB numerical control drilling and milling machine is a typical point motion control system. It is the key equipment for the precision conduction hole processing of printed circuit boards. With the development of electronic products in the direction of miniaturization and miniaturization, the requirements for the aperture, line width, and line spacing of the vias are increasing. Correspondingly, the PCB numerical control system is developing in an open direction with high speed, high precision, high reliability, system integration, flexibility, and high intelligence.
MPC08 economical four-axis motion controller is widely used in PCB numerical control drilling machines for its excellent performance.
First of all, the movement mode of the PCB numerically controlled drilling machine is mainly point motion. Its key technical indicators require high speed and high precision. MPC08 mainly completes the point motion control, can quickly and accurately locate and drill in the instant, and then can quickly move to the next positioning hole on the side after leaving the PCB board surface after lifting, thus greatly improving the work efficiency of the PCB digital drilling machine. . The maximum output frequency of MPC08 is 4MHZ to meet the high speed requirements of PCB drilling machines. Second, the PCB drilling machine requires a large number of IO channels to monitor various device states and control output signals, and each MPC08 motion control card can control 16 universal inputs and 16 general-purpose outputs, while there are 17 dedicated input channels, also when not needed. Can be used as a universal input channel to fully meet the PCB drilling machine I / O channel requirements. In addition, MPC08 also provides users with a secondary development interface to meet the needs of the user's special function development.
MPC08 economical four-axis motion controller is widely used in PCB numerical control drilling machines for its excellent performance.
First of all, the movement mode of the PCB numerically controlled drilling machine is mainly point motion. Its key technical indicators require high speed and high precision. MPC08 mainly completes the point motion control, can quickly and accurately locate and drill in the instant, and then can quickly move to the next positioning hole on the side after leaving the PCB board surface after lifting, thus greatly improving the work efficiency of the PCB digital drilling machine. . The maximum output frequency of MPC08 is 4MHZ to meet the high speed requirements of PCB drilling machines. Second, the PCB drilling machine requires a large number of IO channels to monitor various device states and control output signals, and each MPC08 motion control card can control 16 universal inputs and 16 general-purpose outputs, while there are 17 dedicated input channels, also when not needed. Can be used as a universal input channel to fully meet the PCB drilling machine I / O channel requirements. In addition, MPC08 also provides users with a secondary development interface to meet the needs of the user's special function development.