BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects

Model NO.: acsr
Certification: ISO, RoHS
Model: ACSR
Size: 16/3, 35/6, 50/8, ..........800/70.......1000
Produceing Experience: 15 Years
Export Experience: Southeast Asia, South America, Africa
Export to: USA, South Africa, Middle East
OEM: Yes
Transport Package: Wooden Drum, Steel Wooden Drum, Steel Drum
Specification: SGS
Origin: Henan
HS Code: 761410000
Model NO.: acsr
Certification: ISO, RoHS
Model: ACSR
Size: 16/3, 35/6, 50/8, ..........800/70.......1000
Produceing Experience: 15 Years
Export Experience: Southeast Asia, South America, Africa
Export to: USA, South Africa, Middle East
OEM: Yes
Transport Package: Wooden Drum, Steel Wooden Drum, Steel Drum
Specification: SGS
Origin: Henan
HS Code: 761410000
Aluminium Conductor Steel Reinforced ACSR Conductor

1.Standard:IEC, BS,ASTM,DIN,NF,JIS and So on.
Different specifications and standard can be Customize according to the customer's special request.

2.Experience:more than 15 years manufacture experience

3.Hot sale to Africa,South Africa,Southeast Asia,North America.


4. Here only show ASTM standard Technical Data List,if you want to get more techincal data,pls send e-mail to us.
Code
Name
Nominal Number/Diameter Calculated Area mm2 Diameter mm Resistance
≤Ω/km
Force
KN
Weight
kg/km
AWG or MCM Al
mm
Steel
mm
Al Steel Total
Turkey 6 6/1.68 1/1.68 13.29 2.19 15.48 5.04 2.1586 5.24 54
Swan 4 3/2.12 1/2.12 21.16 3.55 24.71 6.36 1.3557 8.32 85
Swanate 4 7/1.96 1/2.61 21.16 5.35 26.51 6.53 1.3557 10.53 100
Sparrow 2 6/2.67 1/2.67 33.61 5.61 39.22 8.01 0.8535 12.70 136
Sparate 2 7/2.47 1/3.30 33.61 8.52 42.13 8.24 0.8535 16.11 159
Robin 1 6/3.00 1/3.00 42.39 7.10 49.49 9.00 0.6767 15.85 171
Raven 1/0 6/3.78 1/3.37 53.48 8.90 62.38 10.11 0.5364 19.32 216
Quail 2/0 6/3.78 1/3.78 67.42 11.23 78.65 11.34 0.4255 23.62 273
Pigeon 3/0 6/4.25 1/4.25 85.03 14.19 99.22 12.75 0.3373 29.41 343
Penguin 4/0 6/477 1/4.77 107.23 17.87 125.10 14.31 0.2675 37.06 433
Waxwing 266.8 18/3.09 1/3.09 135.16 7.48 142.64 15.45 0.2133 30.27 431
Partridge 266.8 26/2.57 7/2.00 135.16 22.00 157.16 16.28 0.2143 50.29 546
Ostrich 300 26/2.73 7/2.12 152.00 24.71 176.71 17.28 0.1906 56.52 614
Merlin 336.4 18/3.47 1/3.47 170.45 9.48 179.93 17.5 0.1691 38.23 544
Linnet 336.4 26/2.89 7/2.25 170.45 21.81 198.26 18.31 0.1699 62.71 689
Oriole 336.4 30/2.69 7/2.69 170.45 39.81 210.26 18.83 0.1704 77.27 784
Chickadee 397.5 18/3.77 1/3.77 201.42 11.16 212.58 18.85 0.1431 43.99 642
Brant 397.5 24/3.27 7/2.18 201.42 26.13 227.55 19.61 0.1438 64.69 762
Ibis 397.5 26/3.14 7/2.44 201.42 32.77 234.19 19.88 0.1438 72.11 814
Lark 397.5 30/2.92 7/2.92 201.42 46.97 248.39 20.44 0.1442 88.69 927
Pelican 477 18/4.14 1/4.14 241.68 13.42 255.10 20.70 0.1193 52.16 771
Flicker 477 24/3.58 7/2.39 241.68 31.29 272.97 21.49 0.1199 76.66 915
Hawk 477 26/3.44 7/2.67 241.68 39.42 281.10 21.79 0.1199 86.65 978
Hen 477 30/3.20 7/3.20 241.68 56.39 298.07 22.40 0.1201 105.34 1112
Osprey 556.5 18/4.47 1/4.47 282.00 15.68 297.68 22.35 0.1022 60.88 899
Parakeet 556.5 24/3.87 7/2.58 282.00 36.58 318.58 23.22 0.1027 88.22 1067
Dove 556.5 26/3.72 7/2.89 282.00 45.94 327.94 23.55 0.1027 101.03 1140
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects
Packaging for ACSR 
Wooden drum,Steel woodend drum for big size heavy conductor
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects
Our Workshop
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects


If you want to know more about us and our products,pls contact us.
sending email or telephon us:


Linda Lee
Vice General Manager
VERDE XLPE CABLE LIMITED
Tel:0086-371-55611184
Mob:0086-13938400126
Focus on Wires and Cables
Be Your Most Reliable Supplier Aluminium Conductor Steel Reinforced ACSR Conductor

1.Standard:IEC, BS,ASTM,DIN,NF,JIS and So on.
Different specifications and standard can be Customize according to the customer's special request.

2.Experience:more than 15 years manufacture experience

3.Hot sale to Africa,South Africa,Southeast Asia,North America.


4. Here only show ASTM standard Technical Data List,if you want to get more techincal data,pls send e-mail to us.
Code
Name
Nominal Number/Diameter Calculated Area mm2 Diameter mm Resistance
≤Ω/km
Force
KN
Weight
kg/km
AWG or MCM Al
mm
Steel
mm
Al Steel Total
Turkey 6 6/1.68 1/1.68 13.29 2.19 15.48 5.04 2.1586 5.24 54
Swan 4 3/2.12 1/2.12 21.16 3.55 24.71 6.36 1.3557 8.32 85
Swanate 4 7/1.96 1/2.61 21.16 5.35 26.51 6.53 1.3557 10.53 100
Sparrow 2 6/2.67 1/2.67 33.61 5.61 39.22 8.01 0.8535 12.70 136
Sparate 2 7/2.47 1/3.30 33.61 8.52 42.13 8.24 0.8535 16.11 159
Robin 1 6/3.00 1/3.00 42.39 7.10 49.49 9.00 0.6767 15.85 171
Raven 1/0 6/3.78 1/3.37 53.48 8.90 62.38 10.11 0.5364 19.32 216
Quail 2/0 6/3.78 1/3.78 67.42 11.23 78.65 11.34 0.4255 23.62 273
Pigeon 3/0 6/4.25 1/4.25 85.03 14.19 99.22 12.75 0.3373 29.41 343
Penguin 4/0 6/477 1/4.77 107.23 17.87 125.10 14.31 0.2675 37.06 433
Waxwing 266.8 18/3.09 1/3.09 135.16 7.48 142.64 15.45 0.2133 30.27 431
Partridge 266.8 26/2.57 7/2.00 135.16 22.00 157.16 16.28 0.2143 50.29 546
Ostrich 300 26/2.73 7/2.12 152.00 24.71 176.71 17.28 0.1906 56.52 614
Merlin 336.4 18/3.47 1/3.47 170.45 9.48 179.93 17.5 0.1691 38.23 544
Linnet 336.4 26/2.89 7/2.25 170.45 21.81 198.26 18.31 0.1699 62.71 689
Oriole 336.4 30/2.69 7/2.69 170.45 39.81 210.26 18.83 0.1704 77.27 784
Chickadee 397.5 18/3.77 1/3.77 201.42 11.16 212.58 18.85 0.1431 43.99 642
Brant 397.5 24/3.27 7/2.18 201.42 26.13 227.55 19.61 0.1438 64.69 762
Ibis 397.5 26/3.14 7/2.44 201.42 32.77 234.19 19.88 0.1438 72.11 814
Lark 397.5 30/2.92 7/2.92 201.42 46.97 248.39 20.44 0.1442 88.69 927
Pelican 477 18/4.14 1/4.14 241.68 13.42 255.10 20.70 0.1193 52.16 771
Flicker 477 24/3.58 7/2.39 241.68 31.29 272.97 21.49 0.1199 76.66 915
Hawk 477 26/3.44 7/2.67 241.68 39.42 281.10 21.79 0.1199 86.65 978
Hen 477 30/3.20 7/3.20 241.68 56.39 298.07 22.40 0.1201 105.34 1112
Osprey 556.5 18/4.47 1/4.47 282.00 15.68 297.68 22.35 0.1022 60.88 899
Parakeet 556.5 24/3.87 7/2.58 282.00 36.58 318.58 23.22 0.1027 88.22 1067
Dove 556.5 26/3.72 7/2.89 282.00 45.94 327.94 23.55 0.1027 101.03 1140
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects
Packaging for ACSR 
Wooden drum,Steel woodend drum for big size heavy conductor
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects
Our Workshop
BS ASTM GB IEC Standard Overhead Cable ACSR Conductor for Power Plant Substation Projects


If you want to know more about us and our products,pls contact us.
sending email or telephon us:


Linda Lee
Vice General Manager
VERDE XLPE CABLE LIMITED
Tel:0086-371-55611184
Mob:0086-13938400126
Focus on Wires and Cables
Be Your Most Reliable Supplier

LVDS Cable Assembly

UCOAX offers LVDS Assemblies service for oversea customer.


UCOAX has extensive experience in LVDS cable assemblies. We can quote customer requirements using the original parts called out on the customer`s spec sheet (such as Hirose, JST, JAE, TE Connectivity (Tyco), etc.) or also using equivalent parts which usually save time and money. Request a quote for your LVDS Custom Cable Assembly.

Lvds Cable Assembly,Lvds Cables,Lvds Cable Extension,Lvds Cable Assembly Function

UCOAX , https://www.jsucoax.com

Posted on