(1). Certificate: CE and  RoHS
(2). Size: 2ft 3ft 4ft 5ft 6ft 8ft
(3). Luminous Efficacy: 100 lm/W
(4). Color range: Warm white 2700-3500k
      Daylight white 4000-5000k
      Pure white 5000-6500k
      Cool white Above7000k
(5). Light source: SMD 2835
(6). Housing: Aluminum Alloy and High strength PC
(7). Operation temperature: -20degree celsius~+50degree
(8). Light Distribution: 66degree
(9). Input Voltage: 24DC
(10). Frequency: 60Hz to 50Hz
(11). Life time: >50, 000 hrs
(12). Socket Type: T8
(13). Work Environment: Cooler Show Case; Supermarket; Convenience store etc
(14). Clear, Stripy, grey, Frosted cover available.Â
(15). 0.6m/0.9m/1.2m/1.5m/1.8m/2.4m and customized size available.Â
DC24 VÂ low voltage more safety :
The back of light tube equiped with magnet is more beauty and convience in installation.
Can used in supermarket shelves,cosmetic counters and many other comercial places.
NO. | Item | Parameter |
1 | Input voltage | DC24V |
2 | Light source | SMD2835 |
3 | Color temperature | 3000-6500K |
4 | Color rendering index | >80 |
5 | Lighting angle | 66° |
6 | Materail | Aluminum+PC cover |
7 | Operating temperature | below 20~+50ºC |
8 | Strorage temperature | below 20~+50ºC |
9 | service life | 50000hrs |
2, Product Details :


3, LED Cooler Light  Advantage:Â
1).  3years warranty, 50000Hrs lifespan.
2).  Round shape with wide beam angle.
3).  No need fixture, and saving labor fee.
4).  Easy for replacement and maintainence.
5).  Two PCB with powerful wattage.
6).  High quality LED chip from TaiWan.
7).  Isolated driver with top quality and very safe.
4, LED Cooler Light  three types PC Cover
1). Frosted cover: Can acheive soft light, no harm to your eyes
2). Striped cover: Individuation, better light than frosted cover
3). Transparent cover: Can acheive the most effective lighting
5, Replacement  for  conventional  fluorescent  tubes:Â
1. Hotels
2. Conference/meeting room
3. Commercial Complexes
4. Residential/Institution Buildings
5. Schools, colleges &Â Universities
6. Hospitals General lighting, Commercial lighting, plant growing lighting.Â
7. Refrigeratory
8. Advertisement box. etc.Â
6, Our factory :
Shanghai Candor opto electronics tech Co.,Ltd was established in 2002, the headquarters is located in Songjing district ,Shanghia, China, with 3Â branch offices in Hangzhou, Beijing, and Shenzhen.
Candor runs a factory of 5,000 sqm, have 65 professionals with a R&D team of 8.
Candor is the leading provide for the retail shelf lighting system. We intiated the new design and technology to off absolute safe and D.I.Y-installation system for the cosmetics shelf area in the supermarket and lifestyle stores.
Candor would co-work with customers for the tailor-made design and solutions fo the various shelf style and dimensions.


6, The Delivery :

7, FAQ :
(1). Q: How long is the lead time?
  A: If adequate stocks available, products can be delivered in 1 day. Otherwise,
for sample orders, normal samples can be sent in 3-5days; for large quantity orders, products will depart from Shanghai within 15-20 days after the deposit received.
Â
(2).Q: How can I contact with you?Â
  A: Leave a message on our website or sent an email to:  m  ,  or call +86 021 34023321-8006 directly, we will reply you ASAP.
Â
(3).Q: Can you customize products?
  A: Yes, products can be customized according to your requirements. MOQ will be different depending on products available or not.
Â
(4).Q: What about the warranty? What if the products go wrong?
  A: All our bulbs and tubes have at least 2 years warranty, should you have any problems, please contact us directly and we will do our best to solve it.
Â
(5). Q: What about the payment terms?
  A: 30% T/T deposit before production, 70% T/T balance before shipment.
Â
(6). Q: How long should your led light serves?
  A: The lifespan of a led light is decided by the quality of power supply and chip. With good chip and power, our bulbs and tubes can serve 50000  hours.
Â
(7). Q: What certifications do you have for your products?
  A: Our main market is Europeand North  America, so now all our  tubes are CE RoHS listed. As we are expanding the business, we will get our products UL CCC certificated next years.
Â
(8). Q:Do you sell accessaries?
  A:Yes,all accessaries can be sold, please contract us for further details.
Â
(9).How do you control the quality?
  A:All raw materials are sourced by professional buyers, standardized and scientific Quality Controlled Process is in place and strictly executed.Â
Â
(10).Q:How to start the business?
   A:We recommend you our product according to your requirement, if you are satisfied with that, then you make a trail order or sample order to check the quality, if all ok, you can place an order then.

Â
Â
Welcome to your any good news and questions !
Â
Jiangsu Baojuhe Science and Technology Co.,Ltd. , https://www.galvanizedsteelpole.com