Features:
1. Power: 4W
2. Power factor: >0.4
3. Lumen: 360-400LM(3W)
4. Led Type: 2835SMD
5. Input voltage: 220-240V
6. Beam angle: 120 degrees
7. CCT: 3000-6000K
8. Life time: 25, 000 hours
9. No UV or IR radiation
10. Better thermal-dissipation structure
11. CRI>80
Application:
1). Living room, bedroom, kitchen, washroom;
2). School, university, hospital, hotel;
3). Conference, meeting room, show room, showcase;
4). Commercial complexes;
5). Factory, plant, warehouse, office;
6). Supermarket, department store.
Trade Terms:
1. Payment: T/T 30% deposits before production, balance to be paid off before shipment
2. Sample can be delivered in 7 days
3. Shipping freight are quoted under your requests
5. Discounts are offered based on order quantities
6. MOQ: 3000PCS
Item No.: | GR629 |
Power: | 4w |
Power Factor: | >0.4 |
Input Voltage: | 220-240V |
Beam Angle: | 120 degree |
Body Materials: | GLASS |
CCT: | 3000-6000k |
CRI(Ra): | >80 |
LED Type: | 2835SMD |
Base: | MR16 |
Lumen: | 360-400LM |
Product Size: | Φ50*53mm |
Features:
1. Power: 4W
2. Power factor: >0.4
3. Lumen: 360-400LM(3W)
4. Led Type: 2835SMD
5. Input voltage: 220-240V
6. Beam angle: 120 degrees
7. CCT: 3000-6000K
8. Life time: 25, 000 hours
9. No UV or IR radiation
10. Better thermal-dissipation structure
11. CRI>80
Application:
1). Living room, bedroom, kitchen, washroom;
2). School, university, hospital, hotel;
3). Conference, meeting room, show room, showcase;
4). Commercial complexes;
5). Factory, plant, warehouse, office;
6). Supermarket, department store.
Trade Terms:
1. Payment: T/T 30% deposits before production, balance to be paid off before shipment
2. Sample can be delivered in 7 days
3. Shipping freight are quoted under your requests
5. Discounts are offered based on order quantities
6. MOQ: 3000PCS
Item No.: | GR629 |
Power: | 4w |
Power Factor: | >0.4 |
Input Voltage: | 220-240V |
Beam Angle: | 120 degree |
Body Materials: | GLASS |
CCT: | 3000-6000k |
CRI(Ra): | >80 |
LED Type: | 2835SMD |
Base: | MR16 |
Lumen: | 360-400LM |
Product Size: | Φ50*53mm |
High Voltage Linear Power Supplies
HVLP series Linear High Voltage Power Supplies are High-voltage DC Power Supplies that achieve AC/DC conversion through power frequency transformers and transistor loop control. Compared with switching high voltage power supplies, linear high-voltage power supplies have higher stability, higher accuracy, and lower output ripple. And the most important, because of the use of the power frequency AC/DC conversion principle, the linear power supply has no high-frequency radiation interference, and it is especially suitable for use in places with restrictions on EMC and EMI.
The whole series linear power supply adopts industrial-grade metal chassis, pure copper AC/DC multi-insulation high-voltage transformer with varnish treatment, high-reliability multi-transistor filter loop, ensuring the power supplies can run for a long time at full load with high stability, high accuracy, and ultra-low ripple electronic characteristics, equipped with a complete protection circuit, which can better ensure the reliability of the linear power supply itself and the safety of the customer's load.
The output voltage and current can be adjusted by the 10-turn potentiometer with scale and lock on the front, equipped with 4 1/2-digit high-resolution LED meters for output value reading, and RS communication interface can also be added for remote control and monitoring of linear power supplies.
This series of linear high voltage power supplies are mainly used for gas discharge, high-voltage electronic tubes, and can also be applied for other electronic components burn-in test.
Because the output this power supply has HV, the output MUST be connected to the chassis for fixed grounding to ensure the personal safety of the user.
High-voltage Linear Power Supplies,Linear High Voltage Power Supplies, HV Linear Power Supplies, Linear HV Power Supplies, Linear HVPS
Yangzhou IdealTek Electronics Co., Ltd. , https://www.idealtekpower.com