[PConline evaluation] also said before, we will launch our second-generation PConline authentication PC on the scene of ChinaJoy2017, as shown below. At that time, Miss ShowGirl, who is voted on the special page to get the most votes, will be assembled at the scene and auctioned off...
CJ live auction activities:
If you are interested but cannot go to the Shanghai CJ site, you don’t have to be discouraged because the time will be online and offline at the same time, that is, you will be able to shoot it at home. Each of the metafiles and the 5,000-RMB stalls feels that the price is right to play. I feel that you don’t want to be expensive, and you can also look at the excitement.
List of authentication PC configurations:
The performance of the selected accessories is not always the strongest, but the configuration must be reasonable; they are not necessarily top-level, but must be the price that most users can accept, and there will be no special models, we provide solutions The configuration can be purchased at various retail outlets and can enjoy normal nationwide warranty.
As for pricing, it has no price, because only the CJ site is assembled and auctioned off by the beautiful SG, so its value depends on the transaction price of the live auction. The starting price is 1999 yuan, but this price has no reference value.
Of course, maybe you will be interested in this host, want to know how to participate in the auction, and even have questions about its configuration, want to Tucao, it does not matter ~ we will answer this question in the PConline broadcast this afternoon, point Here's a portal to watch the live broadcast, starting at 4pm on July 19th - http://diy.pconline.com.cn/959/9597376.html
Accessories introduction:
This host formally appeared before the CJ, of course, is the first to evaluate the right, or how dare to call the authentication PC.
These accessories are selected through the synthesis of our DIY channel editors, and the principle is to ensure the reliability of the brand, performance, price, materials, workmanship can take into account the outstanding products.
ASUS B250G Gaming Reference Price: Loading... Image Reviews Quote Parameter Overview
ASUS ROG STRIX entry-level motherboard, as long as more than 700 pieces will be able to enjoy the mystery bonus of the eyes of defeat, but also what the motorcycle is wrong.
Sotec GTX1050Ti-4GD5 X-Gaming OC Reference Price: Loading... Image Reviews Price Quotes Overview
Sotec's X-Gaming OC series graphics card can be said to be a big victory this year, sales, quality, reputation are extremely high, cost-effective DIY host can easily choose, anyway, buy this series you will definitely not lose. The GTX1050Ti is equipped with 4GB of video memory, and the mainstream games under the next-level special effects can be smooth enough.
In fact, this price range should be the last GTX1060 level, but affected by the mining boom, GTX1060 is currently not worth the choice, but also no goods let us choose... So we can only retreat and find the configuration GTX1050Ti, also Be a compromise in the context of a particular era.
Crucial MX300 275G SATA Reference Price: Loading... Image Reviews
The company's MX300 275G SATA 3.0 SSD is not very well-known brand, but in fact its products and technologies are very worthy of recognition, because the Flash particles are their own upstream manufacturers. The quality and quality that are provided are not comparable to those brands that can only be assembled or even branded. 275GB capacity, enough to install the system can also install a variety of commonly used software.
Of course, for stand-alone gamers, a game with 50 to 100 G at all is not an SSD, so adding a 3TB mechanical hard drive is also a must. Apart from installing large games, it can also store HD. Video and your own photo.
Intel Core i5-7500 Reference Price: Loading... Image Reviews Quote Parameter Overview
The CPU uses Intel's Core i5-7500, which is the most commonly used game CPU for the current 5000 yuan file. The 4 cores have the highest frequency of 3.8GHz and the TDP is only 65W. At the same time, the performance, heat, and stability are taken into account.
British Rui Sheng platinum sports series DDR4 2400 8G Reference price: Loading... Image reviews Quotation parameters Overview
Like the SSD above, the same brand is the British Rui Da, the particles are provided by the magnesium light, quality, stability are not a problem. The SPD is 1.2V, DDR4 2400, CL16, Intel XMP 2.0 configuration, and the price is not high.
Overclocking Donghai X5 Reference Price: Loading... Image Reviews Quotation Parameters Overview
Overclocking the East China Sea X5 is one of the radiators commonly used in our evaluation room. If it is used on a daily basis, even if the pressure on the i7-7700K is not a problem, the entire system is stable and has excellent heat dissipation performance. Therefore, it is also selected to compress the i7-. 7700K.
HuntKey Cool King Blue Diamond Reference Price: Loading... Image Reviews Quote Parameter Overview
Huntkey Cooler Wang Lan Diamond Edition, HuntKey is currently the No. 1 brand in China. The power word of cool Wang series has always been very good. This time we use the combination of i5+GTX1050Ti, 400W is more than enough, and the blue appearance can also give a Kind of bright new feeling.
Huntkey Night Hunter 3 White Reference Price: Loading... Image Reviews
Hangjia Night Hunter 3 chassis, before the listing of new products, one hundred early price there is a good material and large internal space, can accommodate a variety of ATX motherboards and 400mm long graphics card. The interface is placed on the top of the chassis and it has a strong sense of design.
The above are all parts of the certified PC. In the budget of about 5K, they are not the cheapest models, especially compared to the e-commerce hosts that are very good at cost control. This set of certified PCs has no price advantage, but they are mutually exclusive. The balance between the two is well-matched, there is no risk of shrinking and sacrificing future performance. This is also the reason why they can become certified PCs.
Simple installation process:
Now we must first install the host and run evaluation points, of course, when the CJ site will be a beauty to complete the assembly process, we will also do live online, if you are interested, we must pay attention to our special planning CJ2017 Topic ah.
Plug the plug first, and the normal installation will recommend that you first install the gadgets on the motherboard first, especially the CPU, M.2 SSD, etc. To decide whether to install it first.
CPU power supply line should remember to pull the backplane to this position and then put the mainboard on it. Because the CPU power supply line does not go from behind, the inside of the chassis becomes very messy.
SATA SSD bit
Chassis has a SATA SSD design, alignment position, screw the screw, of course, the best SATA cable to go around the backplane and then back around.
The graphics card, heat sink, and jumper do not show the installation process. After all, Intel's radiator installation is just as it is.
South Bridge Cooling ROG Eye
Then cover the side plate, the host installation will get, because the use of accessories are not light pollution, so the overall host is relatively low-key, but still very practical drop, immediately boot test.
Turn on the measured:
Still familiar with ASUS BIOS
One of the great benefits of choosing ASUS motherboards is that they can enjoy the BIOS of his home. They are very easy to use and have a wide range of functions.
Boot
Because it is a combination of 275GB SSD + 3TB HDD, SSD is not partitioned, HDD is divided into a 1TB D drive, the rest are divided into a district.
Core hardware parameters
Intel i5-7500, 8GB DDR4-2400, STRIX B250G GAMING, Zotac GTX1050Ti, performance parameters are on the table.
CPU performance test:
CPU-Z
International chess
Chess is a common software that can measure CPU multithreading performance. We also like to use CPU running points because it is simple and quick. In fact, the purpose of the test is to confirm whether the host can perform the performance of each accessory stably. After all, an i5 that cannot be overclocked will no longer measure 3% higher than the average. Young people should not think too much about it.
Chess 10546 points and CPU-Z 1509 points are the normal scores of the Core i5-7500, indicating that the i5-7500 can play normally on this platform, and then the CPU full load temperature test.
CPU full load temperature test:
In the room temperature around 25 °C, with the overclocking three East China Sea X5 radiator, Core i5-7500 full load temperature is only 53 °C, is a super low temperature, and can guarantee that in any case, the four cores will not be fully loaded The situation of down-clocking occurs, and this is one of the important factors for the host's long-term high load and stable operation.
3DMARK theoretical performance test:
This link is used to measure the performance of the whole game, 4GB memory GTX1050Ti with Core i5-7500, the composite score is 3416 points, the graphics score is 3622 points, the general GTX1050Ti's results are 3500+, so 3622 points is The scores slightly higher than the average score also indicate that the match between the i5-7500 and the GTX1050Ti does not create a bottleneck for the other party, and each can exert its best performance.
Graphics full load pressure & temperature test
We use the 3DMARK Fire Strike Extreme stress test to test the Zotac GTX1050Ti X-Gaming OC at full load while verifying its heat dissipation capabilities.
This test can squeeze out the full performance of the graphics card, and need to test the performance of more than 97% to pass the test, Sautter GTX1050Ti X-Gaming OC can be 99.5% performance rolling test, indicating that its cooling effect is close to full marks, the entire process The non-full-frequency working time is only 0.5%, which means that the entire test is almost all at full-frequency state, with almost no frequency reduction.
Look at the maximum temperature of the GPU is only 59 °C, which is the host in the two big fever, the CPU and graphics in the summer heat full load temperature does not exceed 60 °C, is not very stable, there is no reliable feeling.
SSD theoretical performance test:
Continuous reading and writing achieved 500/485, 4K performance also had 25/98 performance, SATA SSD in the 256GB grade is in the high level, 940 points is enough to illustrate the problem. Those e-commerce host SSDs, many of which are special models, continuous reading and writing performance is quite tasteless, 300 ~ 500MB / b are common data.
Motherboard Power Supply Module & South Bridge Heat Test
It can be seen that after the CPU is fully loaded for a period of time, the temperature of the current control chip is only 37.5°C, and the temperature of the South Bridge heat sink is only 41.2°C after the host has tested for a period of time. In other words, the entire machine will heat all the accessories, the highest temperature graphics card is only 59 °C ~ ~ is absolutely not stable ah, we choose the accessories is so reliable.
1080P game test:
Since the GTX1050Ti is positioned at a resolution of 1080P or less, there is no need to run 2K or 4K. It can be seen that in the case of 1080P, high ~ highest effects, the above-mentioned large-scale stand-alone games and e-sport games watch pioneer are able to Smooth running, the minimum has reached 51 frames. For more people to play online games, it is even more problematic.
PConline evaluation room summary:
Tested here is almost, in general, the advantages of PConline certification PC of this 5000 yuan file is that it is stable and properly stable.
The selected i5-7500 + GTX1050Ti is on par with the current mainstream e-commerce game console configuration, indicating that its performance is sufficient for most users.
The difference from the e-commerce host is that our SSD has a 275GB Infineon MX300, and the vast majority of e-commerce hosts use 128GB or so SSDs. After six months of use, this type of configuration is easily overwhelmed. problem. In addition, a 3TB HDD has been configured. It is still very practical for large game users. Otherwise, if you have a 275GB SSD, can you install several games?
Finally, return to the stable character, the full load temperature of the accessories does not exceed 60 °C, is already a super cool temperature ~ the hot summer is not empty ah.
Interested in the host, please pay attention to our CJ auction activities ~~!
Small Air Motor,Air Powered Motor,Pneumatic Rotary Motor,Stainless Steel Air Motor
RUDONG HONGXIN MACHINERY CO.,LTD , https://www.rdhxmfr.com