Cooling & Heating Water Chiller

Model NO.: MG-05SFXLRS
Heating Capacity: 21.3 Kw
Trademark: Mango
Transport Package: Plywood
Specification: 710*520*1000
Origin: China
HS Code: 8415812000
Cooling & heating water chiller
 
Model MG-03SFXLRS MG-03SFXLRS/380 MG-05SFXLRS MG-06SFXLRS MG-10SFXLRS MG-12SFXLRS MG-15SFXLRS MG-20SFXLRS MG-25SFXLRS
Heating input power Heating mode KW 2.1 2.35 4.15 4.9 8.35 9.84 10.8 14.5 19.5
Heating capacity KW 10.5 11.8 21.3 25.2 42.6 50.4 56.7 74.8 99.4
COP   5.00 5.02 5.13 5.14 5.10 5.12 5.25 5.16 5.10
cooling input power Cooling mode KW 1.5 1.7 3 3.4 6 6.8 7.7 9.9 13.2
Cooling capacity KW 6.8 7.8 14 16.5 28 33 37.1 49.4 67
EER   4.53 4.59 4.67 4.85 4.67 4.85 4.82 4.99 5.08
pipe size   mm 25 25 25 25 32 32 50 50 65
noise   db 50 50 50 50 50 55 55 55 55
net weight   kg 90 90 123 133 286 306 358 552 592
gross weight   kg 94 94 133 143 301 321 378 582 632
Level of protection IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Electric shock proof grade I I I I I I I I I
cabinet     Galvanized sheet/ Spray coating / gray color
dimension   mm 710*520*1000 710*520*1000 710*520*1000 710*520*1000 1280*830*800 1280*830*800 1320*840*1130 1750*1120*1160 2000*1120*1160
packing dimension   mm 760*570*1130 760*570*1130 760*570*1130 760*570*1130 1330*880*930 1330*880*930 1410*940*1290 1850*1225*1340 2100*1225*1340
Refrigerant     R407C/2.4kg*1 R407C/2.4kg*1 R407C/3.3kg*1 R407C/3.6kg*1 R407C/3.3kg*2 R407C/3.6kg*2 R407C/5kg*2 R407C/7kg*2 R407C/9kg*2
Power supply     220V~240V/50Hz/1ph 380V~415V/50Hz/3ph
Power supply L wire line   Mm2 2.5 2.5 4 6 6 6 10 10 16
Power supply N wire line   Mm2   1.5 2.5 2.5 2.5 2.5 4 4 6
noise   db 50 50 50 50 50 55 55 55 55
compressor model     ZW30KAE ZW34KAE ZW61KAE ZR72KCE ZW61KAE ZR72KCE ZW81KCE ZW108KAE VR144KSE
compressor     Copeland 1pc Copeland 1pc Copeland 2pcs
load side HE     Double-pipe heat exchanger Shell and tube heat exchanger
source side HE     Plate heat exchanger
4-way valve     SHF-11-45D1*1 SHF-11-45D1*1 SHF-20A-46*1 SHF-20A-46*1 2*SHF-20A-46*2 2*SHF-20A-46*2 2*SHF-20A-46*2 2*SHF-35A-79*2 2*SHF-35A-79*2
Thermal expansion valve     Emerson 3Ton Emerson 3Ton Emerson 5Ton Emerson 6Ton Emerson 5Ton*2 Emerson 6Ton*2 Emerson 7.5Ton*2 Emerson 10Ton*2 Emerson 12Ton*2
AC contactor and thermal relay    
Controller   multiple function controller
Protection function   Tempreature protection, time protection, water flow protection, antifreeze protection, current protection
Water pressure switch   0.015Mpa :OFF,  0.03Mpa: ON
High pressure switch   3.0/3.4MPa
Low pressure switch   0.15/0.32MPa
Package   Plywood case
working mode   Heating mode and cooling mode
Remarks:
Exclude: inside water pump, water tank
Changeable items: 1.compressor brand, 2.gas type, 3.cabinet material, 4.power supply according to user's real condition....., price will be changed accordingly.
Working range:source side water inlet temp: 0ºC-40ºC
Rated workong condition:Cooling: source side inlet/outlet water temp: 35ºC/30ºC, load side inlet/outlet water temp: 12ºC/7ºC;  Heating: source side inlet/outlet water temp:15ºC/10ºC,load side inlet/outlet water temp:50ºC/55ºC;

Cooling & Heating Water Chiller

Cooling & Heating Water Chiller


 

Single-element Detector

China leading manufacturers and suppliers of Single-Element Detector

Single-Element Detector,Hortwave Detector Unit,Swir Infrared Detector,Swir Ingaas Unit Detector

Ningbo NaXin Perception Intelligent Technology CO., Ltd. , https://www.nicswir.com

Posted on