SSDs remove the traditional hard disk mechanical architecture and porcelain storage media, use electronic storage media for data storage and read, break through the bottleneck in the access performance of the platform, and have extremely high storage performance. Therefore, they have become the focus of users and gradually become Future market mainstream storage devices. In order to allow customers to better experience the speed experience brought by SSD solid-state drives, some motherboard manufacturers have introduced mSATA interfaces in addition to their original features to fully support SSD solid-state drives.
In order to allow customers to better experience the fast experience brought by SSD solid-state drives, Unika has launched a series of lightning protection super-thin boards that have mSATA interfaces on the motherboard and added Intel Rapid Start Technology quick start technology to match SSD drives. Use, can realize the system starts quickly, and improve systematic operation and game reading speed effectively. At the same time the motherboard also supports PCI-E3.0, USB3.0 and SATA3.0 high-speed interface, and joined the anti-lightning and anti-static technology Emin's original EVO lightning, is a rare motherboard in the same kind of products.
In addition, although the motherboard's on-board SSD solid-state drive has significantly improved data access performance, the performance of the SSD solid-state drive can be maximized if the platform software is set accordingly. And how to set up the platform in order to fully play the SSD solid-state hard drive performance, we will share with you below.
â— System selection is crucial
Because the SSD has fast random access performance, it has a significant speed-up effect on the operation of the system. Therefore, most users will use the SSD as a system disk. In terms of system selection, the Windows 7 system supports SSD solid-state drive optimization, supports 4K alignment of hard disk partitions, supports TRIM commands, etc., and can maximize the performance of SSD solid-state drives. Therefore, users are advised to use the latest Windows 7 system.
â— Separately connect the SSD installation system
When installing the system, only connect the SSD (here mainly refers to installing the Windows 7 system), because the Windows 7 system will automatically detect whether the disk system is optimized for the SSD. If you want to maximize the performance of the SSD, you must connect the SSD to install the system. Otherwise, the system will Because of the multiple discs detected without full optimization, even wacky problems arise. In the process of installing the system to avoid some of the unnecessary problems caused by multiple hard drives, in fact, very simple, as long as the HDD's power cord pulled out, installed the system and then connected on the line.
â— Open AHCI mode
AHCI Serial ATA Advanced Host Interface/Advanced Host Controller Interface is an interface standard jointly developed by several companies under the guidance of Intel. It allows storage drivers to enable advanced Serial ATA functionality. Among the many functions of AHCI, the NCQ feature is crucial to SSD. NCQ is a new hard disk technology. Simply speaking, it is faster to jump from one program to another when it is turned on. To achieve it, you first need to select the AHCI mode in the BIOS.
To turn on the AHCI mode is very simple. Take the Uminus UH77GT solid-state EVO version as an example. After the platform is powered on, press the Delete key to enter the motherboard BIOS.
Go to the SATA Configuration option under the Advanced main menu.
After AHCI is turned on in the SATA Mode Selection sub-item, press F10 to save and turn on the corresponding function. In addition, it is worth mentioning that the AHCI function requires system-driven support, which is why the above-mentioned Windows 7 system was chosen.
â— Turn on TRIM support
TRIM is a technology developed for SSD solid-state drives. The reason is that when data is written on the original mechanical hard disk, Windows will inform the hard disk to erase the previous one and then write the new data to the disk. When deleting data, Windows will only make a mark here. This means that there should be nothing here. When the data is actually written, it will be deleted. The mark will be kept in the disk cache until the disk is idle. It will be executed again. As a result, the disk needs more time to perform the above operation, and the speed will certainly slow down.
When Windows recognizes the SSD and confirms that the SSD supports Trim, when the data is deleted, the HDD will not be notified of the delete command, and only the Volume Bitmap is used to remember that the data has been deleted. Volume Bitmap is just a disk snapshot. It is much faster to set up than directly reading and writing the hard disk to mark the deleted area. This step has already saved a large amount of time. Then when the data is written, since the NAND flash memory stores data in a purely digital form, it is possible to directly write new data to the deleted block in the snapshot according to the situation of the Volume Bitmap, without taking the time to erase. The original data.
The TRIM usually requires an SSD, motherboard chip driver, and system support at the same time. Currently, the SSD and the latest drivers are basically supported. However, some users say that I do not need WIN7. How do I not support it? It is not afraid. The latest version of O&O Defrag 14 supports the sending of TRIM commands. The system does not support users who send TRIM to use it for manual TRIM operations.
â— Partition 4K alignment
The original mechanical hard disk always reads and writes in units of 512-byte sectors, while the latest hard disk specifications finally increase the physical sector to 4KB (4096 bytes). The number of pages that we use nowadays is generally 4KB. Therefore, if the 4K storage format of the SSD is not aligned, it may put a storage file in a maximum of 8 flash memories. The fragmentation of the file is severe and affects the read and write performance of the SSD.
The 4K alignment of the SSD hard disk partition is actually not complicated, and there is more than one way. The simplest and most direct method is to use the Windows 7 system to automatically align the partition function during the installation of the system. Intervention.
Through the above method, the performance of the SSD solid state drive can be maximized, and the service life of the SSD solid state drive can be effectively extended. With the popularity of SSD solid-state drives nowadays, the price has become popular, and it has begun to be popularized among mass users. Unika also quickly followed up. While lightning protection super-polar plates support ordinary SSD solid-state drives, they also joined mSATA. The interface supports mini SSDs to meet the different needs of users. In addition, in order to make better use of the performance of SSD solid-state drives, Unika Lightning Superpolar Plates maximize the performance of SSD solid-state drives by adjusting, setting, and supporting the platforms.
In order to allow customers to better experience the fast experience brought by SSD solid-state drives, Unika has launched a series of lightning protection super-thin boards that have mSATA interfaces on the motherboard and added Intel Rapid Start Technology quick start technology to match SSD drives. Use, can realize the system starts quickly, and improve systematic operation and game reading speed effectively. At the same time the motherboard also supports PCI-E3.0, USB3.0 and SATA3.0 high-speed interface, and joined the anti-lightning and anti-static technology Emin's original EVO lightning, is a rare motherboard in the same kind of products.
In addition, although the motherboard's on-board SSD solid-state drive has significantly improved data access performance, the performance of the SSD solid-state drive can be maximized if the platform software is set accordingly. And how to set up the platform in order to fully play the SSD solid-state hard drive performance, we will share with you below.
â— System selection is crucial
Because the SSD has fast random access performance, it has a significant speed-up effect on the operation of the system. Therefore, most users will use the SSD as a system disk. In terms of system selection, the Windows 7 system supports SSD solid-state drive optimization, supports 4K alignment of hard disk partitions, supports TRIM commands, etc., and can maximize the performance of SSD solid-state drives. Therefore, users are advised to use the latest Windows 7 system.
â— Separately connect the SSD installation system
When installing the system, only connect the SSD (here mainly refers to installing the Windows 7 system), because the Windows 7 system will automatically detect whether the disk system is optimized for the SSD. If you want to maximize the performance of the SSD, you must connect the SSD to install the system. Otherwise, the system will Because of the multiple discs detected without full optimization, even wacky problems arise. In the process of installing the system to avoid some of the unnecessary problems caused by multiple hard drives, in fact, very simple, as long as the HDD's power cord pulled out, installed the system and then connected on the line.
â— Open AHCI mode
AHCI Serial ATA Advanced Host Interface/Advanced Host Controller Interface is an interface standard jointly developed by several companies under the guidance of Intel. It allows storage drivers to enable advanced Serial ATA functionality. Among the many functions of AHCI, the NCQ feature is crucial to SSD. NCQ is a new hard disk technology. Simply speaking, it is faster to jump from one program to another when it is turned on. To achieve it, you first need to select the AHCI mode in the BIOS.
To turn on the AHCI mode is very simple. Take the Uminus UH77GT solid-state EVO version as an example. After the platform is powered on, press the Delete key to enter the motherboard BIOS.
Go to the SATA Configuration option under the Advanced main menu.
After AHCI is turned on in the SATA Mode Selection sub-item, press F10 to save and turn on the corresponding function. In addition, it is worth mentioning that the AHCI function requires system-driven support, which is why the above-mentioned Windows 7 system was chosen.
â— Turn on TRIM support
TRIM is a technology developed for SSD solid-state drives. The reason is that when data is written on the original mechanical hard disk, Windows will inform the hard disk to erase the previous one and then write the new data to the disk. When deleting data, Windows will only make a mark here. This means that there should be nothing here. When the data is actually written, it will be deleted. The mark will be kept in the disk cache until the disk is idle. It will be executed again. As a result, the disk needs more time to perform the above operation, and the speed will certainly slow down.
When Windows recognizes the SSD and confirms that the SSD supports Trim, when the data is deleted, the HDD will not be notified of the delete command, and only the Volume Bitmap is used to remember that the data has been deleted. Volume Bitmap is just a disk snapshot. It is much faster to set up than directly reading and writing the hard disk to mark the deleted area. This step has already saved a large amount of time. Then when the data is written, since the NAND flash memory stores data in a purely digital form, it is possible to directly write new data to the deleted block in the snapshot according to the situation of the Volume Bitmap, without taking the time to erase. The original data.
The TRIM usually requires an SSD, motherboard chip driver, and system support at the same time. Currently, the SSD and the latest drivers are basically supported. However, some users say that I do not need WIN7. How do I not support it? It is not afraid. The latest version of O&O Defrag 14 supports the sending of TRIM commands. The system does not support users who send TRIM to use it for manual TRIM operations.
â— Partition 4K alignment
The original mechanical hard disk always reads and writes in units of 512-byte sectors, while the latest hard disk specifications finally increase the physical sector to 4KB (4096 bytes). The number of pages that we use nowadays is generally 4KB. Therefore, if the 4K storage format of the SSD is not aligned, it may put a storage file in a maximum of 8 flash memories. The fragmentation of the file is severe and affects the read and write performance of the SSD.
The 4K alignment of the SSD hard disk partition is actually not complicated, and there is more than one way. The simplest and most direct method is to use the Windows 7 system to automatically align the partition function during the installation of the system. Intervention.
Through the above method, the performance of the SSD solid state drive can be maximized, and the service life of the SSD solid state drive can be effectively extended. With the popularity of SSD solid-state drives nowadays, the price has become popular, and it has begun to be popularized among mass users. Unika also quickly followed up. While lightning protection super-polar plates support ordinary SSD solid-state drives, they also joined mSATA. The interface supports mini SSDs to meet the different needs of users. In addition, in order to make better use of the performance of SSD solid-state drives, Unika Lightning Superpolar Plates maximize the performance of SSD solid-state drives by adjusting, setting, and supporting the platforms.
Our company is specialized in supplying Manifold Gauge.We have gauges for all common refrigerant like R22,R134A,R410A,R404A,R407C,R32,R1234YF.It applies to wide range of applications, like installation and maintenance of household air conditioner,automobile air conditioner,refrigerator,cold room and other industries .OEM and customization is welcomed.Our parts have been exported to over 50 countries all over the world and are always got good comment by customers.
Manifold Gauge
Manifold Gauge,Manifold Gauge Set,Ac Manifold Gauge Set,Ac Manifold Gauges
ZHEJIANG ICE LOONG ENVIRONMENTAL SCI-TECH CO.,LTD. , https://www.china-refrigerantgas.com