Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor
Product Description
1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.
 Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Item# |
Phase Conductor |
Phase |
Phase Conductor |
Bare Neutral |
Bare |
Bare Neutral messenger Breaking Strength |
Weight Per 1000ft - XLP |
Weight Per 1000ft - Poly |
Rating - XLP |
Rating-Poly |
Pekingese |
6 |
Solid |
45 mls |
6 |
7/w |
563 Lbs |
63.5 Lbs |
61.7 Lbs |
70 Amps |
70 Amps |
Collie |
6 |
7/w |
45 mls |
6 |
7/w |
563 Lbs |
66.8 Lbs |
63.1 Lbs |
70 Amps |
70 Amps |
Dachshund |
4 |
Solid |
45 mls |
4 |
7/w |
881 Lbs |
95.5 Lbs |
93.4 Lbs |
90 Amps |
90 Amps |
Spaniel |
4 |
7/w |
45 mls |
4 |
7/w |
881 Lbs |
100.5 Lbs |
95.4 Lbs |
90 Amps |
90 Amps |
Doberman |
2 |
7/w |
45 mls |
2 |
7/w |
1350 Lbs |
152.7 Lbs |
145.7 Lbs |
120 Amps |
120 Amps |
Malemute |
1/0 |
19/w |
60 mls |
1/0 |
7/w |
1990 Lbs |
242.6 Lbs |
234.2 Lbs |
160 Amps |
160 Amps |
Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor
Product Description
1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.
 Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Item# |
Phase Conductor |
Phase |
Phase Conductor |
Bare Neutral |
Bare |
Bare Neutral messenger Breaking Strength |
Weight Per 1000ft - XLP |
Weight Per 1000ft - Poly |
Rating - XLP |
Rating-Poly |
Pekingese |
6 |
Solid |
45 mls |
6 |
7/w |
563 Lbs |
63.5 Lbs |
61.7 Lbs |
70 Amps |
70 Amps |
Collie |
6 |
7/w |
45 mls |
6 |
7/w |
563 Lbs |
66.8 Lbs |
63.1 Lbs |
70 Amps |
70 Amps |
Dachshund |
4 |
Solid |
45 mls |
4 |
7/w |
881 Lbs |
95.5 Lbs |
93.4 Lbs |
90 Amps |
90 Amps |
Spaniel |
4 |
7/w |
45 mls |
4 |
7/w |
881 Lbs |
100.5 Lbs |
95.4 Lbs |
90 Amps |
90 Amps |
Doberman |
2 |
7/w |
45 mls |
2 |
7/w |
1350 Lbs |
152.7 Lbs |
145.7 Lbs |
120 Amps |
120 Amps |
Malemute |
1/0 |
19/w |
60 mls |
1/0 |
7/w |
1990 Lbs |
242.6 Lbs |
234.2 Lbs |
160 Amps |
160 Amps |
Bitcoin mining equipment is mainly highly specialized ASIC mill , The maximum computing power of a single miner is 110T/s( Ant S19Pro mill ), The scale of computing power of the whole network is 120EH/s above . Ethereum's mining equipment is mainly graphics card mining machine , Professional ASIC Mining machines are very few , On the one hand, it is because of the of Ethereum mining algorithm [ resist ASIC sex " Improved R & D efficiency ASIC The threshold of the miner , So how much do you know about the mainstream Ethereum mining machine ?
Ethereum mining algorithm has higher requirements for memory , The purpose of this design limits ASIC The use of chips in Ethereum mining . From the results , Most Ethereum mining machines are graphics card machines , This reflects the application of Ethereum mining algorithm ASIC Success on . From the absolute value of computational power scale , The computing power of Ethereum is about 200TH/s, The computing power of bitcoin is about 120EH/s, The latter is close to the former 60 ten thousandfold .
ASIC Mining machines have high computing power , Large power consumption , Like the latest ant S19Pro mill , Rated power consumption is 3250W, Need to consume... Every day 78 Degree electricity , According to the current currency price and 0.23 The electricity price in wet season is RMB , The proportion of electricity charge is 30.68%. Other older bitcoins ASIC mill , Like ants T17 series , The proportion of electricity charges generally exceeds 50%. by comparison , The power consumption of the graphics card miner is low , The proportion of electricity is also low . such as 5600XT8 Graphics card miner of card .
Ant S19-95T It adopts aluminum alloy profile electromechanical integrated design , Parallel four fan structure . According to the measured data , In line with and better than the official data .S19 The series is provided by TSMC 7nm chip , A new generation of customized chips with perfect whole machine architecture and high conversion rate APW12 Power Supply , Reduce power loss during conversion , Use more energy-saving , Greatly shorten the return cycle of the miner . In addition, the newly upgraded mining machine operation interface is also more humanized , Real time computing power . The average computing power and the operation of each chip are clear at a glance .
Shenma mining machine M30S-86T/88T/90T, Bit micro 2020 Launched in 2013 M30S Series of new mining machines , Announced that it would M30S The series is expanded to three 3X product . stay 3X In the new standard , Bit micro promises a one-year warranty for its series of products . This series of mining machines are provided by Samsung 8nm chip , Among them, god horse M30S series , The power consumption is 38J/T, Provide higher computing power , Lower power consumption and high stability.
Ethereum Mining Machine:Jasminer X4,Bitmain Antminer E9 (2.4Gh),iPollo V1,Jasminer X4-1U,iPollo V1 Classic,
Jasminer X4-C 1U,iPollo V1 Mini SE Plus
Ethereum Mining Machine,ETHW Miner,innosilicon a10 pro,E9 Antminer,Innosilicon A11
Shenzhen YLHM Technology Co., Ltd. , https://www.ylhm-tech.com