Model NO.: 150W
Certification: CE, C-tick, EMC, ETL, FCC, GS, LVD, PSE, RoHS, SAA, UL
Beam Angle: 120°
LED Chips: Nichia
Product Name: UFO LED High Bay Light
LED Driver: Meanwell Hbg Series
LED Chip: Lumileds SMD3030
Product Type: UL cUL Dlc LED Industrial Lighting
Shape: UFO/Round
PF: >0.95
IP Grade: IP65/IP67/IP68
Body Colour: Black/White
Material: Pure Aluminium 1060
Warranty: 5 Years
Trademark: Cresealight
Transport Package: Pearl Foam Inner Box and K=K Carton
Specification: D290*H170, D340*H180, D400*H194MM
Origin: Made in China
HS Code: 9405409000
Model NO.: 150W
Certification: CE, C-tick, EMC, ETL, FCC, GS, LVD, PSE, RoHS, SAA, UL
Beam Angle: 120°
LED Chips: Nichia
Product Name: UFO LED High Bay Light
LED Driver: Meanwell Hbg Series
LED Chip: Lumileds SMD3030
Product Type: UL cUL Dlc LED Industrial Lighting
Shape: UFO/Round
PF: >0.95
IP Grade: IP65/IP67/IP68
Body Colour: Black/White
Material: Pure Aluminium 1060
Warranty: 5 Years
Trademark: Cresealight
Transport Package: Pearl Foam Inner Box and K=K Carton
Specification: D290*H170, D340*H180, D400*H194MM
Origin: Made in China
HS Code: 9405409000
Technical SpecificationsSize: Ф290*H170, Ф340*H180, Ф400*H194MM
LED type: Lumileds SMD3030, LM80 TM21 certified, Up to150lm/W
Driver brand: Meanwell HBG seriesÂ
Power: 100W, 150W, 200W, 240WÂ
PF>0.95
CRI> 80
Material: 1060 pure aluminum, PC lens and stainless screwsÂ
Working voltage: 100-277V
Luminous Efficiency: 150LM/W
Color temperature: 3000K, 4000K, 5000K, 6000K, 6500KÂ
Beam Angle: 60 /90/120°
Dimmable: 0-10V dimmable
Surface color: Black/WhiteÂ
IP Rating: IP65
Life-span: 50, 000 hours
Power | 100W | 150W | 200W | 240W |
Power consumption | 100W±5W | 150W±5W | 200W±5W | 240W±5W |
Input Voltage | AC100-277V | AC100-277V | AC100-277V | AC100-277V |
Power Frequency | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz |
Output Voltage | DC28.8-48V | DC28.8-48V | DC28.8-48V | DC28.8-48V |
Output Current | 2A(Constant Currrent) | 3.3A(Constant Currrent) | 4.8A(Constant Currrent) | 5.0A(Constant Currrent) |
Luminous Flux | 13500LM(CCT=5000K) | 22500LM(CCT=5000K) | 27000LM(CCT=5000K) | 27000LM(CCT=5000K) |
Fixture Material | 1060 | 1060 | 1060 | 1060 |
LED Type | Lumileds SMD3030 | |||
PowerSupply | MeanWell | |||
System Efficacy | 150LM/WÂ (CCT=5000K) | |||
CCT | 4000K, 5000K, 5700K, 6000K, 6500K | |||
Beam Angle | 60 /90/120 | |||
CRI | >80Ra | |||
System Efficiency | >90% | |||
LED Junction Temperature | <75ºC(Ta=30ºC) | |||
Storage Temperature | (-40~+70ºC) | |||
Operating Temperature | (-30~+50ºC) | |||
Working Environment | 15-90%RH | |||
Power Efficiency | >93% | |||
Power Factor | >0.93 | |||
Total Harmonic Distortion | <15% | |||
Luminaire Net Weight | 3.2kg | 4.2kg | 5.5kg | 6.5kg |
Package Size | 350*350*200mm | 400*400*215mm | 460*460*230mm | 460*460*230mm |
Certificates | UL CU L DLC TUV-GS CB SAA RCM FCC CE RoHS | |||
Life span | >50000Hrs(Ta=30ºC @L70) | |||
Ingress Protection | IP65 | |||
Quality Warranty | 5years | |||
Installation | Lifting, Tube, Wall Installation |
Product DescriptionÂ
PF>0.95, CRI >80Ra, THD<15%Â
Anti-thunder: 4KVÂ
IK Grade: IK10
Surge Protection: 10KV
LED Junction Temperature: ≤65°C
Working Temperature: -40ºC~+50ºCÂ
Humidity: 10%~90%RH
Lumileds SMD3030, 150lm/w
Meanwell driver, 100-277VAC, 90-305V, 180-528V also available
Optional Function: DALI, 1-10V dimmable, daylight sensor, microwave sensor
Material: Pure aluminium 1060, Optical lens, stainless screwsÂ
Ideal mounting height: 8-15 m
Simple and elegant appearance, anodized housing, durable.
Unique UFO shape, lighter and smaller, no reflector, saving much freight cost.
Wide aluminium plate +Â large diameter PCB, heat dissipation fast and evenly.
All stainless screws prevent bad situation.Â
One-piece PC lens and high-quality silicone ring for excellent airtight effect, protecting from heavy rain and dust in tunnel lighting circumstances Certification: UL, cUL, DLC, TUV, GS, CB, SAA, FCC, CE, RoHS.Â
Warranty: 5Â years
Product Advantages:Â
UL Meanwell driver
Lumileds SMD3030, 150lm/w
Non-dimmable and dimmable are the same price
Adopted hydraulic technology of Pure aluminium 1060.
Chimney structure heat dissipation, air convection effect, good thermal management system, improving heat dissipation performance to long life time.
Pure aluminium is Hydraulic technology, thermal conductivity coefficient is 220W/m. k
The performance of thermal conductivity of Pure aluminium 1060 is faster 200% than profile extruded aluminium 6063.Â
The performance of thermal conductivity of Pure aluminium 1060 is faster 275% times than Die-cast aluminium ADC12.Â
Weight is light 3.2kg, saving much freight cost and high performance cost ratio.Â

Installation:Â Loop & Hook hanging / Wall mount / Surface mount / Rack mount

Applications
1. factories, industrial production workshop, warehouse;
2. gym, stadiums, golf courses,
3. commercial establishments, overpasses, outdoor advertising board, landmarks;
4. stage, yard, garden, lawn, park, plaza;
5. supermarket, shopping mall, exhibition hall;
6. ships, airports, subways, gas station, the train station, highway toll station, dockÂ
7. factory, office, meeting room, conference hall, storeroom, etc.Â


User Manual:
Switch off power of the mains supply or respectively of the connection lead before doing any works.
Assembly must not damage or destroy conducting paths.
Make sure that the product is mounted on a stable, even and tilt-fixed background.
The complete installation must be done by an electrical expert who is familiar with the valid directives.
Quaity Control:Â Â
Stability TEST: make sure 100% of the lamps be aging test at least 48hours Â
Lighting TEST:Â make sure 100% of the lamps be lighted before packing
Drop TEST: make sure every single light have been well protected by box
Contact:
Peony Jin
Mobile:0086-158 1858 6160
Please feel free to send us your inquiry, We are at your service any time!
 Technical Specifications
Size: Ф290*H170, Ф340*H180, Ф400*H194MM
LED type: Lumileds SMD3030, LM80 TM21 certified, Up to150lm/W
Driver brand: Meanwell HBG seriesÂ
Power: 100W, 150W, 200W, 240WÂ
PF>0.95
CRI> 80
Material: 1060 pure aluminum, PC lens and stainless screwsÂ
Working voltage: 100-277V
Luminous Efficiency: 150LM/W
Color temperature: 3000K, 4000K, 5000K, 6000K, 6500KÂ
Beam Angle: 60 /90/120°
Dimmable: 0-10V dimmable
Surface color: Black/WhiteÂ
IP Rating: IP65
Life-span: 50, 000 hours
Power | 100W | 150W | 200W | 240W |
Power consumption | 100W±5W | 150W±5W | 200W±5W | 240W±5W |
Input Voltage | AC100-277V | AC100-277V | AC100-277V | AC100-277V |
Power Frequency | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz |
Output Voltage | DC28.8-48V | DC28.8-48V | DC28.8-48V | DC28.8-48V |
Output Current | 2A(Constant Currrent) | 3.3A(Constant Currrent) | 4.8A(Constant Currrent) | 5.0A(Constant Currrent) |
Luminous Flux | 13500LM(CCT=5000K) | 22500LM(CCT=5000K) | 27000LM(CCT=5000K) | 27000LM(CCT=5000K) |
Fixture Material | 1060 | 1060 | 1060 | 1060 |
LED Type | Lumileds SMD3030 | |||
PowerSupply | MeanWell | |||
System Efficacy | 150LM/WÂ (CCT=5000K) | |||
CCT | 4000K, 5000K, 5700K, 6000K, 6500K | |||
Beam Angle | 60 /90/120 | |||
CRI | >80Ra | |||
System Efficiency | >90% | |||
LED Junction Temperature | <75ºC(Ta=30ºC) | |||
Storage Temperature | (-40~+70ºC) | |||
Operating Temperature | (-30~+50ºC) | |||
Working Environment | 15-90%RH | |||
Power Efficiency | >93% | |||
Power Factor | >0.93 | |||
Total Harmonic Distortion | <15% | |||
Luminaire Net Weight | 3.2kg | 4.2kg | 5.5kg | 6.5kg |
Package Size | 350*350*200mm | 400*400*215mm | 460*460*230mm | 460*460*230mm |
Certificates | UL CU L DLC TUV-GS CB SAA RCM FCC CE RoHS | |||
Life span | >50000Hrs(Ta=30ºC @L70) | |||
Ingress Protection | IP65 | |||
Quality Warranty | 5years | |||
Installation | Lifting, Tube, Wall Installation |
Product DescriptionÂ
PF>0.95, CRI >80Ra, THD<15%Â
Anti-thunder: 4KVÂ
IK Grade: IK10
Surge Protection: 10KV
LED Junction Temperature: ≤65°C
Working Temperature: -40ºC~+50ºCÂ
Humidity: 10%~90%RH
Lumileds SMD3030, 150lm/w
Meanwell driver, 100-277VAC, 90-305V, 180-528V also available
Optional Function: DALI, 1-10V dimmable, daylight sensor, microwave sensor
Material: Pure aluminium 1060, Optical lens, stainless screwsÂ
Ideal mounting height: 8-15 m
Simple and elegant appearance, anodized housing, durable.
Unique UFO shape, lighter and smaller, no reflector, saving much freight cost.
Wide aluminium plate +Â large diameter PCB, heat dissipation fast and evenly.
All stainless screws prevent bad situation.Â
One-piece PC lens and high-quality silicone ring for excellent airtight effect, protecting from heavy rain and dust in tunnel lighting circumstances Certification: UL, cUL, DLC, TUV, GS, CB, SAA, FCC, CE, RoHS.Â
Warranty: 5Â years
Product Advantages:Â
UL Meanwell driver
Lumileds SMD3030, 150lm/w
Non-dimmable and dimmable are the same price
Adopted hydraulic technology of Pure aluminium 1060.
Chimney structure heat dissipation, air convection effect, good thermal management system, improving heat dissipation performance to long life time.
Pure aluminium is Hydraulic technology, thermal conductivity coefficient is 220W/m. k
The performance of thermal conductivity of Pure aluminium 1060 is faster 200% than profile extruded aluminium 6063.Â
The performance of thermal conductivity of Pure aluminium 1060 is faster 275% times than Die-cast aluminium ADC12.Â
Weight is light 3.2kg, saving much freight cost and high performance cost ratio.Â

Installation:Â Loop & Hook hanging / Wall mount / Surface mount / Rack mount

Applications
1. factories, industrial production workshop, warehouse;
2. gym, stadiums, golf courses,
3. commercial establishments, overpasses, outdoor advertising board, landmarks;
4. stage, yard, garden, lawn, park, plaza;
5. supermarket, shopping mall, exhibition hall;
6. ships, airports, subways, gas station, the train station, highway toll station, dockÂ
7. factory, office, meeting room, conference hall, storeroom, etc.Â


User Manual:
Switch off power of the mains supply or respectively of the connection lead before doing any works.
Assembly must not damage or destroy conducting paths.
Make sure that the product is mounted on a stable, even and tilt-fixed background.
The complete installation must be done by an electrical expert who is familiar with the valid directives.
Quaity Control:Â Â
Stability TEST: make sure 100% of the lamps be aging test at least 48hours Â
Lighting TEST:Â make sure 100% of the lamps be lighted before packing
Drop TEST: make sure every single light have been well protected by box
Contact:
Peony Jin
Mobile:0086-158 1858 6160
Please feel free to send us your inquiry, We are at your service any time!
Â
Miniaturized High Voltage Switchgear
Miniaturized High Voltage Switchgear,High Tension Switchgear,Hv Switch Gear,Lv And Hv Switchgear
TRANCHART Electrical and Machinery Co.,LTD , https://www.tranchart-electrical.com