The sound is hard: there is harmonic distortion, the degree of distortion is between 3% and 5%
Explosion of sound: too much high-frequency or middle-high frequency, there are harmonics and intermodulation distortion.
The sound is sandy: medium and high frequency distortion, with transient distortion.
The sound is dry: there is distortion, a little more in the middle and high frequencies, and there is transient distortion.
The sound is boring: there are too few high-frequency or mid-high frequencies, or the directivity is too sharp to deviate from the axis.
The sound is muddy: the transient is not good, the speaker resonance peak is prominent, and there are too many low or medium and low frequencies.
The sound is thick: the frequency bandwidth is good, the middle frequency and low frequency are good, and the reverberation is moderate.
Slim sound: Moderate high-frequency and mid-high frequency, low distortion, good transient, no transient intermodulation distortion.
There are layers: good transient, flat frequency characteristics, and moderate reverberation.
The sound is solid: the mid-low frequency is good, the reverb is moderate, and the loudness is sufficient.
Sound divergence: lack of intermediate frequency, poor intermediate frequency transient, excessive reverberation.
Narrow sound: narrow frequency characteristics.
Metal lead sound: individual points in the middle and high frequencies are prominent, and the distortion is serious.
The sound is round: the frequency characteristics and distortion indicators are good, the reverb is moderate, and the transient is good.
Moisture: The mid-high frequency and high frequency are good, and the reverberation is sufficient.
Bright sound: mid-high frequency and high frequency are sufficient, the frequency response is flat, and the reverberation is moderate.
Spiked voice: too much high frequency and mid-high frequency.
Virtual sound (floating): Lack of mid-frequency, mid-high frequency and high-frequency directivity are too sharp.
Sound dry: lack of reverberation and mid-to-high frequencies.
Balance or concord: good frequency characteristics and low distortion.
Roar: The resonance peak of the speaker is seriously prominent, the distortion is large, and the transient is not good
Transparency: Moderate high-frequency and mid-high frequency, low distortion and good transient.
Good clarity: good mid-to-high frequency and high frequency, low distortion, good transient, and moderate reverberation.
Powerful somatosensory: flat frequency response, moderate reverberation, low distortion and good transient.
Presence or presence: the frequency response is good for transients, the characteristics are good in the middle and high frequencies, the distortion is small, and the stereo effect is good.
Fullness: Frequency bandwidth, good mid-low frequency, moderate reverberation.
Soft: Appropriate amount of low-frequency and mid-low frequency, low distortion.
Courage and good strength: sufficient loudness, good reverberation, good low and mid-low frequencies.

Follow WeChat

Download Audiophile APP

Follow the audiophile class
related suggestion