- Model NO.: electrical wire
- Conductor Type: Stranded
- Conductor Material: Copper
- Insulation Material: PVC
- Range of Application: Indoors
- Brand: Huatong
- Size Range: 0.75-4 M²
- Experience: 30 Years
- Trademark: Huatong
- Specification: single core and multicore
- HS Code: 8544492100
- Type: Insulated
- Application: Light Appliances
- Sheath Material: PVC
- Material Shape: Round Wire
- Certification: ISO9001, CE, UL, CCC, RoHS
- Number of Cores: 1-5
- Factory: 100,000m²
- Voltage: 450/750V
- Transport Package: Roll/Reel
- Origin: China
  (1)Production capacity:10000km/month
  (2)MOQ:100m
  (3)Delivery:5~15 officail days.
  (4)Standards:IEC,ASTM,DIN,BS; or according to customers' requirements.
  (5)Package: 100meters/roll, or on request.

SPECIFICATION
(1) Electrical Wire include models BV, BLV, BVR, RVV, RVVB etc.(2) Basic structure of PVC insulated wires: copper conductor PVC insulated and PVC sheathed wires Â
(3) Application: Household and building
(4) Standard matched: CCC, IEC,ISO14001:2004,ISO9001:2008
(5) Low voltage
(6) Flexible or ordinary
(7) A/C voltage: 450/750v or below
                        300/500v or below
(8) Sinle core or multi cores
(9) Insulation colour: Black, Brown, Yellow, Blue, Red,Green/Yellow, Grey, Orange, Â White is also available.
(10) Maximum conductor temperature:70°C
    Maximum conductor temperature during short Circuit:160°c
    Cable 20°C water into 1h,infliction 2500V volage 5min,insulated to do not roke throuth.
(11)Â Customrized Type is acceptable.
STANDARDS:
BS EN 50525-3-11 (HD21.14), BS EN/IEC 60332-1-2, BS EN/IEC 60332-3-24.C
TYPE & NAME:
Modle |          Name                                                   |
BV | copper core PVC insulated power wire |
BVR | copper core PVC insulated flexible  power wire |
BLV | aluminum core PVC insulated power wire |
BVVB | copper core PVC insulated PVC sheathed parallel power wire |
BLVVB | aluminum core PVC insulated , PVC sheathed wire |
RVS | copper core PVC insulated twisted fexible wire |
RVVB | copper core PVC insulated sheath flat flexible wire |
KEY TECHNICAL
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA | NOMINAL THICKNESS OF INSULATION | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
 | mm² | mm | mm | kg/km |
2 | 0.75 | 0.6 | 6.3 | 57 |
2 | 1 | 0.6 | 6.6 | 65 |
2 | 1.5 | 0.7 | 7.4 | 84 |
2 | 2.5 | 0.8 | 9 | 130 |
2 | 4 | 0.8 | 10.4 | 180 |
3 | 0.75 | 0.6 | 6.7 | 68 |
3 | 1 | 0.6 | 7 | 78 |
3 | 1.5 | 0.7 | 8 | 107 |
3 | 2.5 | 0.8 | 9.9 | 163 |
3 | 4 | 0.8 | 11.1 | 212 |
4 | 0.75 | 0.6 | 7.3 | 83 |
4 | 1 | 0.6 | 7.9 | 100 |
4 | 1.5 | 0.7 | 9 | 134 |
4 | 2.5 | 0.8 | 10.8 | 201 |
4 | 4 | 0.8 | 12.2 | 290 |
5 | 0.75 | 0.6 | 8.1 | 103 |
5 | 1 | 0.6 | 8.3 | 130 |
5 | 1.5 | 0.7 | 10.4 | 170 |
5 | 2.5 | 0.8 | 12.1 | 255 |
5 | 4 | 0.8 | 15 | 360 |

Your best choice: Huatong Cable Inc.Â
 (1),More than 30 years experience.
 (2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
 (3),Sound Quality Control
   --Material inspection;
   --manufacturing inspection;
   -- Finished products inspection;
   -- Inspection before delivery.
   --Third party inspection.
  -- Inspection of storage at port of departure.
 (4),ISO Certificated.
 (5) ,Plenty of material and lobor gurantee the delivery prompt and price competitive.
 (6),24/7 service

Male Pin Headers & Min Jumper Series
Mini Jumper:The short-circuit cap is a 1.27mm,2.00mm, 2.54mm 5.08mm circuit sheet metal. As long as it is 2 pins, the short-circuit cap can be used to short it.
What is the function of the short circuit cap? Short circuit cap, I call it short circuit block. For example, if you use a single row of pins, you can use the short circuit block to short circuit the two adjacent pins (that is, to realize the connection on the circuit). For example, if you have a three wire pin, you can use a short circuit block to realize the function of dial switch.