Medium Voltage Aluminium Conductor Abc Cable

Model NO.: JKLYJ
Trademark: Jiapu
Specification: any one
Origin: Henan China
HS Code: 4101962331
Model NO.: JKLYJ
Trademark: Jiapu
Specification: any one
Origin: Henan China
HS Code: 4101962331
Medium voltage aluminium conductor abc cable
Product Description

1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.


3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Item#
 

Phase Conductor

  Size AWG
 

Phase

Conductor

Stranding
 

Phase Conductor

Insulation Thickness
 

Bare Neutral

Messenger

Size AWG
 

Bare

Neutral Strand
 

Bare Neutral messenger Breaking Strength
 

Weight Per 1000ft - XLP
 

Weight Per 1000ft - Poly
 

Rating - XLP
 

Rating-Poly
 

Pekingese
 

6
 

Solid
 

45 mls
 

6
 

7/w
 

563 Lbs
 

63.5 Lbs
 

61.7 Lbs
 

70 Amps
 

70 Amps
 

Collie
 

6
 

7/w
 

45 mls
 

6
 

7/w
 

563 Lbs
 

66.8 Lbs
 

63.1 Lbs
 

70 Amps
 

70 Amps
 

Dachshund
 

4
 

Solid
 

45 mls
 

4
 

7/w
 

881 Lbs
 

95.5 Lbs
 

93.4 Lbs
 

90 Amps
 

90 Amps
 

Spaniel
 

4
 

7/w
 

45 mls
 

4
 

7/w
 

881 Lbs
 

100.5 Lbs
 

95.4 Lbs
 

90 Amps
 

90 Amps
 

Doberman
 

2
 

7/w
 

45 mls
 

2
 

7/w
 

1350 Lbs
 

152.7 Lbs
 

145.7 Lbs
 

120 Amps
 

120 Amps
 

Malemute
 

1/0
 

19/w
 

60 mls
 

1/0
 

7/w
 

1990 Lbs
 

242.6 Lbs
 

234.2 Lbs
 

160 Amps
 

160 Amps
 
Medium voltage aluminium conductor abc cable
Product Description

1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.


3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Item#
 

Phase Conductor

  Size AWG
 

Phase

Conductor

Stranding
 

Phase Conductor

Insulation Thickness
 

Bare Neutral

Messenger

Size AWG
 

Bare

Neutral Strand
 

Bare Neutral messenger Breaking Strength
 

Weight Per 1000ft - XLP
 

Weight Per 1000ft - Poly
 

Rating - XLP
 

Rating-Poly
 

Pekingese
 

6
 

Solid
 

45 mls
 

6
 

7/w
 

563 Lbs
 

63.5 Lbs
 

61.7 Lbs
 

70 Amps
 

70 Amps
 

Collie
 

6
 

7/w
 

45 mls
 

6
 

7/w
 

563 Lbs
 

66.8 Lbs
 

63.1 Lbs
 

70 Amps
 

70 Amps
 

Dachshund
 

4
 

Solid
 

45 mls
 

4
 

7/w
 

881 Lbs
 

95.5 Lbs
 

93.4 Lbs
 

90 Amps
 

90 Amps
 

Spaniel
 

4
 

7/w
 

45 mls
 

4
 

7/w
 

881 Lbs
 

100.5 Lbs
 

95.4 Lbs
 

90 Amps
 

90 Amps
 

Doberman
 

2
 

7/w
 

45 mls
 

2
 

7/w
 

1350 Lbs
 

152.7 Lbs
 

145.7 Lbs
 

120 Amps
 

120 Amps
 

Malemute
 

1/0
 

19/w
 

60 mls
 

1/0
 

7/w
 

1990 Lbs
 

242.6 Lbs
 

234.2 Lbs
 

160 Amps
 

160 Amps
 

Screw Compressor Series Sealed Terminal Board

Screw Compressor Series Sealed Terminal Board,Commercial Semi-Enclosed Compressors,Semi-Enclosed Compressor Terminal,Semi-Enclosed Compressor Seal Terminal Panel

Shenzhen Capitol Micro-Electronics Co.,LTD , https://www.capitolgtms.com

Posted on