Model NO.: Rb-Hb-200WU2
Certification: CE, EMC, LVD, RoHS, SAA, UL, VDE
Beam Angle: 120°
LED Chips: SMD3030
Item No.: Rb-Hb-200wu2
Input Voltage: AC100-277V
LED Power: 200W
LED Chip: SMD3030
Luminous Flux: 28000lm
Color Rendering Index: >78
Power Factor: >0.98
Power Efficiency: >91%
LED Driver: Meanwell Hbg
IP Rate: IP65
Trademark: Rayborn
Transport Package: 1PCS/Box
Specification: CE/ROHS/SAA/UL
Origin: China
HS Code: 9405409000
Model NO.: Rb-Hb-200WU2
Certification: CE, EMC, LVD, RoHS, SAA, UL, VDE
Beam Angle: 120°
LED Chips: SMD3030
Item No.: Rb-Hb-200wu2
Input Voltage: AC100-277V
LED Power: 200W
LED Chip: SMD3030
Luminous Flux: 28000lm
Color Rendering Index: >78
Power Factor: >0.98
Power Efficiency: >91%
LED Driver: Meanwell Hbg
IP Rate: IP65
Trademark: Rayborn
Transport Package: 1PCS/Box
Specification: CE/ROHS/SAA/UL
Origin: China
HS Code: 9405409000
Motion Sensor 200watt UFO Induction Warehouse LED High Bay Light Product Specifications
LED High Bay Light/Industrial High Bay LED Lighting (100-250W)
200W UFO LED HIGH BAY-120DÂ | |||
Item No.: | RB-HB-200WU2 | ||
Input Voltage: | AC 100-277V | ||
Freqency Range: | 50Hz~60Hz | ||
LED Chip: | SMD3030 Chip | ||
Power Driver: | Meanwell HBG | ||
Power Factor: | >0.98 | ||
Power Efficiency: | >92% | ||
Luminous Efficiency: | 140LM/W | ||
LED Power | 200W | ||
LED QTY:Â | 252pcs 3030SMD | ||
LED Working Voltage: | DC 42~48V | ||
System Consumption: | 205W | ||
LIGHT Luminous Flux | Warm White | 22070LM | |
Pure White | 23700LM | ||
Cool White | 24300LM | ||
Viewing Angle: | 120/90/60 degree | ||
 Center Luminance | Height 5M | 383LUX | |
Height 10M | 96LUX | ||
Height 15M | 43LUX | ||
Illuminance Area | Height 5M | Dia.1606CMÂ points visible | |
Height 10M | Dia.3213CM points visible | ||
Height 15M | Dia.4819CM points visible | ||
Illuminance Uniformity: | >0.6 | ||
Color Temperature | Warm White | 3000K~3500K | |
Pure White | 4000K~5500K | ||
Cool White | 6000K~6500K | ||
Color Rendering Index | Ra>80 | ||
Light Distribution: | LED points visible | ||
LED Junction Temperature: | ≤115ºC | ||
Working Temperature: | -40ºC~50ºC | ||
IP Grade: | IP65 | ||
Working Life-span: | 50000 H | ||
Power Line: | 1.0 mm three line | ||
Connect Wire | Brown | L | |
Blue | N | ||
Yellow / Green | G | ||
Certificate | CE/SAA/UL/ROHS | ||
Size: | Ф388*H196 | ||
Net Weight: | 5.5KG | ||
Packaging | 47*47*21cm |

UFO LED High bay Lamp Features:
1. Using SMD3030 LED(80-250W)as the light source, with unique lighting design of Multi-chip integrated single-module; Select for excellent imported semiconductor chip, it has high thermal conductivity, low luminous decay, pure colors and no heavy shade etc.
2. The unique design of radiator which can combine with the lamp box perfectly, diffuse the heat conduction efficiently, so that reduce the temperature of inside lamp, it ensures the LED longlife-span.
3. The surface of radiator is treated by antiseptic and anodic oxidation; With compact structure and aesthetic appearance.
4. Environment-friendly, no air pollution, no lead-free, no-mercury.
5. With high color rendering index which can show a true color of things for people, kinds of light colors are available, meet the requirement of different environment; Clear up the depressive mood caused by lower or higher color temperature compared with conventional lamp, make more comfortable for people's eyes which can greatly improve people's working efficiency.
6. Adopted advanced constant current controlling techniques; Wide voltage range available and global universal; Overcome the lighting instability caused by electric network of ballast and noise pollution; Avoid the stimulation and tiredness taking from long-time work.
7. Apply for unique surface treatment technology, welldecorated, novel style, easy to install, lower maintenance cost and wide in application.
UFO LED High bay Competitive Advantage:
1. CE & RoHS & TUV&SAA approved, Quality Guaranteed
2. Imported original SMD3030 LED chip, superior light source
3. OEM & ODM welcome, independent R&D ability, patent design.
4. Fast delivery, 2-15 workdays depends on order quantity after payment confirmed
5. Reliable quality & credit, 3-5 years warranty and 50.000 hours lifespan
UFO LED High bay light dimension :

UFO LED High bay light Application and installation :
1. Workshop and factory lighting.
2. Shopping mall lighting.
3. Museum, stadium and gymnasium lighting.
4. Highway toll station and gas station lighting.
5. Warehouse and smeltery lighting.

UFO LED High bay light 12hours aging test :
All LED lights will be over 12 hours aging tested, inspection department
will test 100% products including light up test , power wattage test ,
highVoltage test , waterproof test , ground connection test and so on,
defective rate is controlled  less than 0.1%. Quality is ensured, you can
be assured.

LED High bay light Shipment and Packaging :
Our individual package maximize protecting LED high bay lights from transfer damage in transit.
1. Label on backside of each led high bay lights and your required label is available.Â
2. One piece led high bay Light per carton. Â
3. This is our regular packing of  led high bay lamps,if you need,we can also custom color packing  and put your logo on it.

Company Information:
Rayborn Lighting Co.,Ltd is a professional manufacturer ,focus on Industrial LED lights and commerical LED lights research ,devolopment ,production,sales ,on service,was in High-end operation and service provider in High-power led .Under the country "saving "polics,we are striving to create environment protection ,energy saving ,long life lighting and earned a reputation of being a quality supplier of LED lighting .
We has a group of professional technical R & D team, who can provide the OEM / ODM services according to customers and LED lighting solutions,our factory has passed the authentications of ISO9001:2000,CE, FCC, ROSH ,TUV authentication.

Payment terms :
1. Payment: T/T, L/C at sight, Western Union ,Paypal available
2. Samples can be available within 5-7 working days; Order: 10-20Days
3. Shipping freight is quoted under your requests
4. Shipping port:Shenzhen , ChinaÂ
5. Discouts are offered based on order quantities
After-sales service :Â
1. We offer 3-5 years warranty base on different price and products.
2. Any quality issue, we will replace for free within guarantee period.
3. Any accessories, we always support our customers.Â
FAQ:Â
1. What is the general business process?
Answer : Send Inquiry to Rayborn. → Specification Confirmation → Quotation → Sample List Confirm → Proforma Invoice → Payment Bank Slip → Sample Delivery → Sample Satisfactory → Bulk Order List → Proforma Invoice → 30% Deposit Payment in Advance → Production Ready → 70% Balance bank slip → Delivery → After Sale Service
Â
2. What is the warranty?
Answer : 5 years warranty is offered depending on different types of lights. If item fails due to quality problem during warranty, we can send new replacement with freight on ours immediately if urgently. Or we prefer to send replacement with next order.
3. What is the payment term?
Answer : For sample order, we can accept T/T, Paypal, West Union, 100% in advance. For bulk order, 30% deposit in advance by T/T, 70% balance before shipping. For very big order, L/C is negotiable
Â
4. Can I add my logo on the product label?
Answer : Yes, but order quantity is requested depending on different lights.
Â
5. I don't know how many UFO Led High bay Light should I use, can you advise?
Answer : Yes, we can offer our professional solution for you, IES file is available if you have the design team.
6. Do you have any MOQ limit for led light order?
Answer: Low MOQ, 1pc for sample checking is available .
7. How do you ship the goods and how long does it take to arrive?
Answer: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
8. How to proceed an order for led light?
Answer : Firstly let us know your requirements or application. Secondly We quote according to your requirements or our suggestions. Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
9. How to deal with the faulty ?
Answer : Firstly, Our products are produced in strict quality control system and the defective rate <Â 0.2%.
Secondly, during the guarantee period, we will send new lights with new order for small quantity. For
defective batch products, we will send out new replacement to you immediately for you to solve the problem.
 Motion Sensor 200watt UFO Induction Warehouse LED High Bay LightÂ
Product Specifications
LED High Bay Light/Industrial High Bay LED Lighting (100-250W)
200W UFO LED HIGH BAY-120DÂ | |||
Item No.: | RB-HB-200WU2 | ||
Input Voltage: | AC 100-277V | ||
Freqency Range: | 50Hz~60Hz | ||
LED Chip: | SMD3030 Chip | ||
Power Driver: | Meanwell HBG | ||
Power Factor: | >0.98 | ||
Power Efficiency: | >92% | ||
Luminous Efficiency: | 140LM/W | ||
LED Power | 200W | ||
LED QTY:Â | 252pcs 3030SMD | ||
LED Working Voltage: | DC 42~48V | ||
System Consumption: | 205W | ||
LIGHT Luminous Flux | Warm White | 22070LM | |
Pure White | 23700LM | ||
Cool White | 24300LM | ||
Viewing Angle: | 120/90/60 degree | ||
 Center Luminance | Height 5M | 383LUX | |
Height 10M | 96LUX | ||
Height 15M | 43LUX | ||
Illuminance Area | Height 5M | Dia.1606CMÂ points visible | |
Height 10M | Dia.3213CM points visible | ||
Height 15M | Dia.4819CM points visible | ||
Illuminance Uniformity: | >0.6 | ||
Color Temperature | Warm White | 3000K~3500K | |
Pure White | 4000K~5500K | ||
Cool White | 6000K~6500K | ||
Color Rendering Index | Ra>80 | ||
Light Distribution: | LED points visible | ||
LED Junction Temperature: | ≤115ºC | ||
Working Temperature: | -40ºC~50ºC | ||
IP Grade: | IP65 | ||
Working Life-span: | 50000 H | ||
Power Line: | 1.0 mm three line | ||
Connect Wire | Brown | L | |
Blue | N | ||
Yellow / Green | G | ||
Certificate | CE/SAA/UL/ROHS | ||
Size: | Ф388*H196 | ||
Net Weight: | 5.5KG | ||
Packaging | 47*47*21cm |

UFO LED High bay Lamp Features:
1. Using SMD3030 LED(80-250W)as the light source, with unique lighting design of Multi-chip integrated single-module; Select for excellent imported semiconductor chip, it has high thermal conductivity, low luminous decay, pure colors and no heavy shade etc.
2. The unique design of radiator which can combine with the lamp box perfectly, diffuse the heat conduction efficiently, so that reduce the temperature of inside lamp, it ensures the LED longlife-span.
3. The surface of radiator is treated by antiseptic and anodic oxidation; With compact structure and aesthetic appearance.
4. Environment-friendly, no air pollution, no lead-free, no-mercury.
5. With high color rendering index which can show a true color of things for people, kinds of light colors are available, meet the requirement of different environment; Clear up the depressive mood caused by lower or higher color temperature compared with conventional lamp, make more comfortable for people's eyes which can greatly improve people's working efficiency.
6. Adopted advanced constant current controlling techniques; Wide voltage range available and global universal; Overcome the lighting instability caused by electric network of ballast and noise pollution; Avoid the stimulation and tiredness taking from long-time work.
7. Apply for unique surface treatment technology, welldecorated, novel style, easy to install, lower maintenance cost and wide in application.
UFO LED High bay Competitive Advantage:
1. CE & RoHS & TUV&SAA approved, Quality Guaranteed
2. Imported original SMD3030 LED chip, superior light source
3. OEM & ODM welcome, independent R&D ability, patent design.
4. Fast delivery, 2-15 workdays depends on order quantity after payment confirmed
5. Reliable quality & credit, 3-5 years warranty and 50.000 hours lifespan
UFO LED High bay light dimension :

UFO LED High bay light Application and installation :
1. Workshop and factory lighting.
2. Shopping mall lighting.
3. Museum, stadium and gymnasium lighting.
4. Highway toll station and gas station lighting.
5. Warehouse and smeltery lighting.

UFO LED High bay light 12hours aging test :
All LED lights will be over 12 hours aging tested, inspection department
will test 100% products including light up test , power wattage test ,
highVoltage test , waterproof test , ground connection test and so on,
defective rate is controlled  less than 0.1%. Quality is ensured, you can
be assured.

LED High bay light Shipment and Packaging :
Our individual package maximize protecting LED high bay lights from transfer damage in transit.
1. Label on backside of each led high bay lights and your required label is available.Â
2. One piece led high bay Light per carton. Â
3. This is our regular packing of  led high bay lamps,if you need,we can also custom color packing  and put your logo on it.

Company Information:
Rayborn Lighting Co.,Ltd is a professional manufacturer ,focus on Industrial LED lights and commerical LED lights research ,devolopment ,production,sales ,on service,was in High-end operation and service provider in High-power led .Under the country "saving "polics,we are striving to create environment protection ,energy saving ,long life lighting and earned a reputation of being a quality supplier of LED lighting .
We has a group of professional technical R & D team, who can provide the OEM / ODM services according to customers and LED lighting solutions,our factory has passed the authentications of ISO9001:2000,CE, FCC, ROSH ,TUV authentication.

Payment terms :
1. Payment: T/T, L/C at sight, Western Union ,Paypal available
2. Samples can be available within 5-7 working days; Order: 10-20Days
3. Shipping freight is quoted under your requests
4. Shipping port:Shenzhen , ChinaÂ
5. Discouts are offered based on order quantities
After-sales service :Â
1. We offer 3-5 years warranty base on different price and products.
2. Any quality issue, we will replace for free within guarantee period.
3. Any accessories, we always support our customers.Â
FAQ:Â
1. What is the general business process?
Answer : Send Inquiry to Rayborn. → Specification Confirmation → Quotation → Sample List Confirm → Proforma Invoice → Payment Bank Slip → Sample Delivery → Sample Satisfactory → Bulk Order List → Proforma Invoice → 30% Deposit Payment in Advance → Production Ready → 70% Balance bank slip → Delivery → After Sale Service
Â
2. What is the warranty?
Answer : 5 years warranty is offered depending on different types of lights. If item fails due to quality problem during warranty, we can send new replacement with freight on ours immediately if urgently. Or we prefer to send replacement with next order.
3. What is the payment term?
Answer : For sample order, we can accept T/T, Paypal, West Union, 100% in advance. For bulk order, 30% deposit in advance by T/T, 70% balance before shipping. For very big order, L/C is negotiable
Â
4. Can I add my logo on the product label?
Answer : Yes, but order quantity is requested depending on different lights.
Â
5. I don't know how many UFO Led High bay Light should I use, can you advise?
Answer : Yes, we can offer our professional solution for you, IES file is available if you have the design team.
6. Do you have any MOQ limit for led light order?
Answer: Low MOQ, 1pc for sample checking is available .
7. How do you ship the goods and how long does it take to arrive?
Answer: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
8. How to proceed an order for led light?
Answer : Firstly let us know your requirements or application. Secondly We quote according to your requirements or our suggestions. Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
9. How to deal with the faulty ?
Answer : Firstly, Our products are produced in strict quality control system and the defective rate <Â 0.2%.
Secondly, during the guarantee period, we will send new lights with new order for small quantity. For
defective batch products, we will send out new replacement to you immediately for you to solve the problem.
Â
MPPT Controller,Mppt Solar Inverter,MPPT Solar Controller,MPPT Solar Charge Controller
Jinan Xinyuhua Energy Technology Co.,Ltd , https://www.xyhenergy.com