Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light

Certification: CE, C-tick, EMC, Energy Star, ETL, FCC, GS, LVD, PSE, RoHS, SAA, UL, cUL Dlc
Operating Voltage: 85-265V
Input Voltage: 110V
LED Chips Brand: Nichia
LED Type: SMD3030 with Lm80 Report
Luminous Efficiency: 135lm/W
Colour(CCT): 3000K, 4000K, 5000K, 6000K, RGB
Driver Brand: Meanwell
Voltage: 85-265VAC, 100-277VAC, 90-305V, 180-528V
Optional Function: Daylight Sensor
Beam Angle: 120 Degree
Waterproof Grade: IP65
Body Colour: Black / Gray
Material: Pure Aluminum, Toughened Glass, Silicone Ring
Trademark: Cresealight
Transport Package: Pearl Foam Inner Box and K=K Carton
Specification: 152*216*40MM
Origin: Made in China
HS Code: 9405409000
Certification: CE, C-tick, EMC, Energy Star, ETL, FCC, GS, LVD, PSE, RoHS, SAA, UL, cUL Dlc
Operating Voltage: 85-265V
Input Voltage: 110V
LED Chips Brand: Nichia
LED Type: SMD3030 with Lm80 Report
Luminous Efficiency: 135lm/W
Colour(CCT): 3000K, 4000K, 5000K, 6000K, RGB
Driver Brand: Meanwell
Voltage: 85-265VAC, 100-277VAC, 90-305V, 180-528V
Optional Function: Daylight Sensor
Beam Angle: 120 Degree
Waterproof Grade: IP65
Body Colour: Black / Gray
Material: Pure Aluminum, Toughened Glass, Silicone Ring
Trademark: Cresealight
Transport Package: Pearl Foam Inner Box and K=K Carton
Specification: 152*216*40MM
Origin: Made in China
HS Code: 9405409000
Technical Specifications
LED Type: SMD3030 with LM80 report
Luminous efficiency: 135LM/W
Colour(CCT): 3000k, 4000k, 5000k, 6000k, RGB 
Driver Brand: Meanwell 
Size: 152*216*40,167*226*40,220*30*50,245*354*55,295*402*60,360*470*60mm
Power: 10W/20W/30W/50W/80W/100W/150W/200W
Frequency: 50/60Hz
Input Voltage: 85-265VAC, 100-277VAC, 90-305V, 180-528V also available
Optional Function: Daylight Sensor 
Beam Angle: 120°
PF>0.95, CRI >80Ra, THD<15%     
Anti-thunder: 4KV                                                                                                                                                                                                 IK Grade: IK10
Surge Protection: 10KV
LED Junction Temperature: ≤65ºC
Working Temperature:  -40ºC~+50ºC
Storage Temperature: -40ºC~+70ºC 
Humidity: 10%~90%RH   
Corrosion-proof grade: Wf2 
Anti-wind level: 17hurricane
Waterproof Grade: IP65                                                                                                                                                                                       Material: Pure Aluminum, toughened glass, silicone ring
Body Colour: Black / Gray 
Material: Pure Aluminum, toughened glass, silicone ring
Installation: mounting bracket,screws 
Life-span: 50, 000 hours
Certificates: UL cUL DLC, TUV, GS, CB, SAA, FCC, CE&RoHS
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light


Product Features
1.Ultra-thin streamlined design, simple and elegant appearance, stylish and classic 
2.Innovative design, Efficient protection
Innovative G-buckle technology, prevent glass off, free of screw fixing, simple and elegant, easy for installation  
3. Professional optical design, luminous efficiency increased by 50% 
The same condition, our brightness of led flood light is higher 50% than traditional flood light 
4. High-quality silicone ring for excellent airtight effect, protecting from heavy rain and dust in tunnel lighting circumstances 
5. Total 8 models of heat sink,full range from 10W to 200W, choose anyone you need
6. Pure aluminium structure of heat dissipation 
7. Undergone a 5000hour salt spray test, which boasts outstanding resistance to corrosion
8. Approved by a professional wind tunnel test, it can be withstand a level 17hurricane
9. 270°adjustable
10. Protection grade IP65
11. Anti-wind level 17hurricane
12. Quick waterproof connectors 
13. 3030 SMD LED, 135lm/w
14. Meanwell driver, 5 year's warranty
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light

Installation
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light




Applications
Widely used in bars, clubs, hotels, stages, park, sculpture, square, parking lot, playground, shopping mall, plazas, exhibition hall, commercial buildings facade, mosques, museums, art galleries, historical buildings, factories, gymnasiums, stadium, isles, yard, advertising boards, billboards, buildings, lawns, national green lighting projects, building facade and public corridor, stair corridor, garden designs and some other indoor and outdoor places where need spot lighting and light decoration,etc
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light


User Manual:
Switch off power of the mains supply or respectively of the connection lead before doing any works.
Assembly must not damage or destroy conducting paths.
Make sure that the product is mounted on a stable, even and tilt-fixed background.
The complete installation must be done by an electrical expert who is familiar with the valid directives.

Quaity Control:  
Stability TEST: make sure 100% of the lamps be aging test at least 48hours  
Lighting TEST: make sure 100% of the lamps be lighted before packing
Drop TEST: make sure every single light have been well protected by box

Contact:
Peony Jin
Mobile:0086-158 1858 6160
Please feel free to send us your inquiry, We are at your service any time! Technical Specifications
LED Type: SMD3030 with LM80 report
Luminous efficiency: 135LM/W
Colour(CCT): 3000k, 4000k, 5000k, 6000k, RGB 
Driver Brand: Meanwell 
Size: 152*216*40,167*226*40,220*30*50,245*354*55,295*402*60,360*470*60mm
Power: 10W/20W/30W/50W/80W/100W/150W/200W
Frequency: 50/60Hz
Input Voltage: 85-265VAC, 100-277VAC, 90-305V, 180-528V also available
Optional Function: Daylight Sensor 
Beam Angle: 120°
PF>0.95, CRI >80Ra, THD<15%     
Anti-thunder: 4KV                                                                                                                                                                                                 IK Grade: IK10
Surge Protection: 10KV
LED Junction Temperature: ≤65ºC
Working Temperature:  -40ºC~+50ºC
Storage Temperature: -40ºC~+70ºC 
Humidity: 10%~90%RH   
Corrosion-proof grade: Wf2 
Anti-wind level: 17hurricane
Waterproof Grade: IP65                                                                                                                                                                                       Material: Pure Aluminum, toughened glass, silicone ring
Body Colour: Black / Gray 
Material: Pure Aluminum, toughened glass, silicone ring
Installation: mounting bracket,screws 
Life-span: 50, 000 hours
Certificates: UL cUL DLC, TUV, GS, CB, SAA, FCC, CE&RoHS
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light


Product Features
1.Ultra-thin streamlined design, simple and elegant appearance, stylish and classic 
2.Innovative design, Efficient protection
Innovative G-buckle technology, prevent glass off, free of screw fixing, simple and elegant, easy for installation  
3. Professional optical design, luminous efficiency increased by 50% 
The same condition, our brightness of led flood light is higher 50% than traditional flood light 
4. High-quality silicone ring for excellent airtight effect, protecting from heavy rain and dust in tunnel lighting circumstances 
5. Total 8 models of heat sink,full range from 10W to 200W, choose anyone you need
6. Pure aluminium structure of heat dissipation 
7. Undergone a 5000hour salt spray test, which boasts outstanding resistance to corrosion
8. Approved by a professional wind tunnel test, it can be withstand a level 17hurricane
9. 270°adjustable
10. Protection grade IP65
11. Anti-wind level 17hurricane
12. Quick waterproof connectors 
13. 3030 SMD LED, 135lm/w
14. Meanwell driver, 5 year's warranty
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light

Installation
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light




Applications
Widely used in bars, clubs, hotels, stages, park, sculpture, square, parking lot, playground, shopping mall, plazas, exhibition hall, commercial buildings facade, mosques, museums, art galleries, historical buildings, factories, gymnasiums, stadium, isles, yard, advertising boards, billboards, buildings, lawns, national green lighting projects, building facade and public corridor, stair corridor, garden designs and some other indoor and outdoor places where need spot lighting and light decoration,etc
Outdoor Energy Saving 10W/20W/30W/50W/60W/70W/80W/100W/120W/140W/150W/160W/180W/200W/280W/300W/400W/500W/600W/800W/ 140lm/W Professional Airport LED Flood Light


User Manual:
Switch off power of the mains supply or respectively of the connection lead before doing any works.
Assembly must not damage or destroy conducting paths.
Make sure that the product is mounted on a stable, even and tilt-fixed background.
The complete installation must be done by an electrical expert who is familiar with the valid directives.

Quaity Control:  
Stability TEST: make sure 100% of the lamps be aging test at least 48hours  
Lighting TEST: make sure 100% of the lamps be lighted before packing
Drop TEST: make sure every single light have been well protected by box

Contact:
Peony Jin
Mobile:0086-158 1858 6160
Please feel free to send us your inquiry, We are at your service any time!

Precision Stainless Steel Band

Precision Stainless Steel Band,Decorative Stainless Steel Strips,Stainless Steel Belt Buckles,Stainless Steel Flat Trim Strips

ShenZhen Haofa Metal Precision Parts Technology Co., Ltd. , https://www.haofametals.com

Posted on