(Part 2 of the Tendering) Datang Treasure Huayin Electric Power Co., Ltd. Jinzhushan Thermal Power Generation Branch #1 and #2 Units Announced Tender Invitation and Bidding for Ultra-Low-emission Desulfurization Capacity Increase Reconstruction Project

(Part 2 of the Tendering) Datang Huayin Mining and Recruiting Co., Ltd. Jinzhushan Thermal Power Generation Branch #1 and #2 Units Announced Tender Invitation and Bidding for Ultra-Low-emission Desulfurization Capacity Increase Reconstruction Project

Pursuant to the Law of the People's Republic of China on Tendering and Bidding, the Regulations on the Implementation of the Tender and Bidding Law of the People's Republic of China, and relevant laws and regulations, the principles of openness, fairness, impartiality, and good faith are followed. Datang Huayin Caizhao Co., Ltd. Jinzhushan Thermal Power Generation Co., Ltd. The company's entrustment, the #1, # 2 unit ultra-low emission desulfurization capacity expansion project for domestic open tender, welcome to meet the qualification requirements of the participating units.

I. Project Description:

Datang Huayin Mining Co., Ltd. Jinzhushan thermal power generation branch ultra-low emission # 1 and # 2 unit desulphurization and dust removal integrated transformation project. Project location: Taiping Village, Shatangwan Town, Lengshuijiang City, Hunan Province. Contracting period: The desulphurization of unit #1 was implemented during the maintenance of Unit #1 in 2017, and the desulfurization of Unit #2 was carried out during the maintenance of Unit #2 in 2018.

Second, the scope of the tender:

The scope of the tender is Datang Huayin Mining Co., Ltd. Jinzhushan Thermal Power Generation Branch # 1 and # 2 unit ultra-low emission desulphurization and dust removal integrated transformation project, using the EPC general contracting method. The overall scheme for the desulfurization unit #1 of the generating unit adopts an efficient flue gas equalizing device and an efficient mist eliminator, removes the existing D slurry circulation pump and the corresponding spray layer, and replaces the original spray layer and nozzle. Add two slurry circulation pumps and two spray layers. Remove the original demister and replace it with an efficient demister. The original flue and the flue gas and flue steel brackets will be transformed accordingly. When the bidders guarantee that the SO2 concentration at the inlet of the desulfurization equipment is 4000mg/Nm3 under the conditions of designing the coal type, boiler BMCR conditions, and processing 100% flue gas volume, the SO2 concentration at the outlet of the desulfurization equipment is less than 35mg/Nm3, and the desulfurization efficiency is not less than 99.13%. The overall scheme for the desulfurization of Unit #2 is to adopt an efficient flue gas equalizing device + an efficient mist eliminator, remove the original demister, and replace it with an efficient mist eliminator. The original flue and the clean flue were modified accordingly. When the bidders guarantee that the SO2 concentration at the inlet of the desulfurization equipment is 4000mg/Nm3 under the conditions of designing coal types, boiler BMCR conditions, and handling 100% flue gas volume, the SO2 concentration at the outlet of the desulfurization equipment is less than 35mg/Nm3, and the desulfurization efficiency is not less than 99.13%.

The detailed work content and technical requirements shall be based on the final record of the bidding documents.

Third, the bidder's qualification requirements:

The bidder shall have the ability to perform the contract satisfactorily and shall meet the following conditions:

3.1 The bidder has registered within the territory of the People's Republic of China with the right to an independent legal person and to independently enter into a contract.

3.2 The bidder has not cancelled any contract in any project contract in the past 3 years, or has been terminated due to his own reasons.

3.3 The Bidder shall have the special Grade A design qualification of the Environmental Engineering (Air Pollution Prevention and Control Engineering) issued by the Ministry of Housing and Urban-Rural Development of the People's Republic of China, and may engage in the corresponding construction project general contracting business and project management and related technologies within the scope of the qualification certificate. Professional contracting qualifications with management services or environmental engineering.

3.4 If the construction (construction, installation, anti-corrosion) part is subcontracted, the sub-contracted units must have qualifications for the qualifications of the mining and contracting project and qualifications for the mechanical and electrical equipment installation engineering, professional contracting for grades of or above, and qualifications for the construction project. Grade A and above qualifications and anti-corrosion engineering contractor qualifications.

3.4 In the past five years, the bidder must have two or more independently completed units with a capacity of 600MW and above for the FPC EPC project general contracting performance. The performance provided by the Bidder must be true. If there is a problem with fraud, the bidder will be disqualified (provide the owner/user certificate and attach the owner/user contact information; otherwise it will not be accepted).

3.5 This tender does not accept the bid of the Consortium. The legal representative is two or more legal persons of the same person. The parent company, wholly-owned subsidiary and its holding company may not bid at the same time in the same goods bidding.

Fourth, the tender documents obtained:

4.1 Ways to Obtain Bidding Documents: Log in, apply for the bidding document with the company's CA certificate electronic key and follow-up bids.

4.2 Bidding Documents Available: November 15 to November 25, 2016.

2) The result of the purchase is subject to the platform.

4.3 After the tender has adopted the post-qualification method, the bid evaluation committee will review the qualifications of the bidders after the bid opening. The bidders' bids that do not meet the requirements of the tender notice will be treated as rejected bids.

V. Submission of tender documents:

5.1 Deadline for submitting tender documents (Bid deadline, the same below): December 10, 2016, 10:00 am.

5.2 Delivery Location: Beijing.

5.3 Ways of submission: Prior to the deadline for submitting tender documents, potential bidders submitted paper tender documents and their electronic versions according to the requirements of the tender documents, and completed the electronic uploading and uploading of electronic tender documents on e-commerce platforms. Written documents submitted late or not delivered to designated locations or not sealed as required will not be accepted by the tenderee.

5.4 Other submission methods and issues requiring attention: The electronic version of the bidding documents needs to be submitted on the platform, and the electronic opening and evaluation of bids shall be implemented. Do not open the bidder's written bid documents, sing the target, only for archiving use.

The opening of the bid is subject to the electronic bid opening method. For bidders who are not familiar with the online bidding operation, we will hold a training conference.

Contact: Qian Yong

Mobile:

phone

fax

E-mail:

In order to ensure that you can bid smoothly, please consult the bidding agency or the tenderer for detailed requirements for bidding before bidding or purchasing the bidding documents. The specific requirements and project conditions shall be interpreted by the bidding agency or the tenderee.

Touch Panel For Iphone

Touch Panel For Iphone,Touch Screen Digitizer Panel,Touch Screen Panel For Iphone,Phone Touch Screen

Shenzhen Xiangying touch photoelectric co., ltd. , https://www.starstp.com

Posted on