Do not know if you are the same idea as me? Before K1 came out 0 yuan purchase, I read the introduction feels like a Ponzi scheme (see the configuration cost itself should be 30-40 within the router, the calibration price is much higher than Aunt Zhang often recommend 69 yuan artifact newifi, and newifi Configuration 128M memory is still higher than K2's 64M memory), so when I was mentioned by friends around, I always persuaded them to be cautious. In addition, there have been rumors that Fiji's routers will secretly upload user data statistics in the background, and I have never wanted to move the idea of ​​buying 0 yuan.
Until last month, when I saw Jingdong actually had an activity to purchase 3 K2 and then offer 60 yuan, my heart moved, plus my home newifi went to a room separated by 2 walls and my parents didn't signal (I used Is newifi, the microblogging activities opened the open wireless route sent, with a half a year later brushed the padavan firmware), I thought there Jingdong to Fiscal endorsement, it should not be running off the bar; not enough to take advantage of the Psychological, background upload data problems I have brush machine experience, to brush your firmware, so you want to steal the data no way. Checked the Internet under the brush Raiders, confidence explosion, the moment the next single, Jingdong this express is awesome, the next day sent.
Here's a picture of buying 3 sets of -60 discounts.
The three K2s just arrived at the top and bottom were checked on the Internet. This time it was a new package:
And then on the retired newifi map:
Give everyone a look at K2's fresh dead angle from all angles:
Original Fifi official firmware interface:
Now enter the brush process:
First of all, I'm just a rookie. I've consulted several Raiders on the Internet. I'm just a little white and I've summarized it into a very simple and easy-to-operate way. I hope to introduce it to everyone so that everyone can successfully
The two most important links to the Raiders (thanks to the authors of the two Raiders, as well as many great gods who have dedicated tools and optimized firmware for Brush):
Brush Breed Raiders
Firmware introduction link (this link also has constantly updated firmware):
The first step: preparation
Download Brush Tool, Firmware
Link: WebDisk Address Password: hrx4
Unplug the network cable between the fiber modem (commonly known as optical cat or fiber cat) and the wireless router, and restore the router to factory settings. Then use a network cable to connect the LAN port of the router to the computer. Can't use a wireless network to connect to a router.
Step 2: Open the Breed Web Brush Console Common Assistant, then unzip the Breed Web Brush Console Common Assistant (Firewall prompts for full access). Right - Run as administrator
The software first set as shown in the figure, then click to start the brush breed, etc.
Come out below this do not need to allow access
Brush success will have this prompt
After that, you can close all windows
Step 3: Enter Breed Brush Firmware
After brushing into the breed, wait several tens of seconds and then unplug the router. Then press and hold the reset button (Reset button). Do not let go. At the same time, plug in the power and wait for 5 seconds. Pay attention to the computer's network connection, wait until you get ip, then enter 192.168.1.1 to enter the interface (breed web recovery console)
It is recommended that you back up the EEPROM and programmer firmware before breathing
Also reply to restore factory settings! ! Otherwise, it may result in a slower network speed. Select the default public version.
Follow the steps below to upload the firmware
Click update again
Wait about 1 minute
The router will automatically restart, enter 192.168.1.1 in the address bar (this address can be entered by running the command cmd input ipconfig check), enter the default user name admin password admin
You're done!
Test speed
Set automatic restart, here I set the restart script every day at half past three:
Stick directly in
Reboot every week at 1-5am (add it yourself)
30 3 1,2,3,4,5 reboot & Remove start command
After brushing the firmware, I would like to return to the web web console: Unplug the router power, then press the reset button and do not let go. At the same time, plug in the power and then release it after three seconds. Open 192.168.1.1 and enter the web web console. ! !
In addition, you can also install advertising shielding assistant adbyby automatic proxy server SS, etc., you can refer to the two big God posts posted by me.
The following is the personal experience of using:
Appearance: fairly stylish, white appearance is still very beautiful at home, it looks atmosphere.
Firmware use experience: If you do not brush machine, then often there will be plugged in cable but can not recognize the situation, basically not after the brush machine. So proof must be brush machine ah. Padavan's firmware is very powerful and highly playable.
Signal: The signal is still full at every 3 walls, which is 2 levels stronger than newifi. However, in fact, it seems that it is only strong. In fact, the speed is not as fast. Of course, it is much stronger than newifi.
Waiting for $0 to buy back money, if the normal payment, then count the cost-effective choice, if you are in a home environment with a low demand for the router, only to receive signals everywhere, fully meet your needs .
After finishing the work ~ thanks for watching