PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable

Model NO.: YJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: YJLV22
Brand: Upward
High Voltage Cable Conductor: Copper
High Voltage Cable Sectional Areas: 150mm2
High Voltage Cable Outer Sheath: Polyethylene
Cable Voltage: 10kv-35kv
Cable Standard: IEC60332
Cable Packing: Plastic Reel
Cable Sectional Area: 1.5mm2-16mm2
Trademark: Upward
Transport Package: Stainless Steel Plate Packing
Specification: 1000meters/roll
Origin: China
HS Code: 8544491100
Model NO.: YJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: YJLV22
Brand: Upward
High Voltage Cable Conductor: Copper
High Voltage Cable Sectional Areas: 150mm2
High Voltage Cable Outer Sheath: Polyethylene
Cable Voltage: 10kv-35kv
Cable Standard: IEC60332
Cable Packing: Plastic Reel
Cable Sectional Area: 1.5mm2-16mm2
Trademark: Upward
Transport Package: Stainless Steel Plate Packing
Specification: 1000meters/roll
Origin: China
HS Code: 8544491100
Parameters of high-voltage cable
High-voltage cable is a kind of power cable and means the power cable for transmitting the voltage within 10KV-35KV (1KV=1000V), and is mostly applied in the main road of power transmission. The executive standards of high-voltage cable product are GB/T 12706.2-2008 and GB/T 12706.3-2008. 
Detailed description
Conductor: Copper or aluminum
Insulation: Cross-linked polyethylene
Filler: Filler strip
Packaging: Wood shaft or packaging bag, depending on your requirement
Outer sheath: 
Armoring: Fine steel wire armoring or steel tape armoring
Service characteristics of high-voltage cable: This product is applicable to the fixed laying lines for power supply, transmission and distribution with AC rated voltage of 35KV and below. The maximum long-time operating temperature of cable conductor is 90ºC, and in case of short circuit (not exceeding 5S at most), the maximum temperature of cable conductor is not greater than 250ºC. 
Standard sectional areas: 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2. 
Type Name Application
YJV
YJLV
Cross-linked polyethylene-insulated, PVC-sheathed power cable
Cross-linked polyethylene-insulated, PVC-sheathed aluminum power cable
Overhead, indoors, tunnel, cable trench
YJV22
YJLV22
Cross-linked polyethylene-insulated, steel tape-armored, PVC-sheathed power cable
Cross-linked polyethylene-insulated, steel tape-armored, PVC-sheathed aluminum power cable
Indoors, tunnel, cable trench and underground
YJV32
YJLV32
Cross-linked polyethylene-insulated, fine steel wire-armored, PVC-sheathed power cable
Cross-linked polyethylene-insulated, fine steel wire-armored, PVC-sheathed aluminum power cable
High drop, vertical shaft and underwater
Note: Add ZC to the original model of flame-retardant cable of the Company, NH to fire-resistant cable, and WDZN to low-smoke, halogen-free, flame-retardant and fire-resistant cable. 
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable

  Parameters of high-voltage cable
High-voltage cable is a kind of power cable and means the power cable for transmitting the voltage within 10KV-35KV (1KV=1000V), and is mostly applied in the main road of power transmission. The executive standards of high-voltage cable product are GB/T 12706.2-2008 and GB/T 12706.3-2008. 
Detailed description
Conductor: Copper or aluminum
Insulation: Cross-linked polyethylene
Filler: Filler strip
Packaging: Wood shaft or packaging bag, depending on your requirement
Outer sheath: 
Armoring: Fine steel wire armoring or steel tape armoring
Service characteristics of high-voltage cable: This product is applicable to the fixed laying lines for power supply, transmission and distribution with AC rated voltage of 35KV and below. The maximum long-time operating temperature of cable conductor is 90ºC, and in case of short circuit (not exceeding 5S at most), the maximum temperature of cable conductor is not greater than 250ºC. 
Standard sectional areas: 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2. 
Type Name Application
YJV
YJLV
Cross-linked polyethylene-insulated, PVC-sheathed power cable
Cross-linked polyethylene-insulated, PVC-sheathed aluminum power cable
Overhead, indoors, tunnel, cable trench
YJV22
YJLV22
Cross-linked polyethylene-insulated, steel tape-armored, PVC-sheathed power cable
Cross-linked polyethylene-insulated, steel tape-armored, PVC-sheathed aluminum power cable
Indoors, tunnel, cable trench and underground
YJV32
YJLV32
Cross-linked polyethylene-insulated, fine steel wire-armored, PVC-sheathed power cable
Cross-linked polyethylene-insulated, fine steel wire-armored, PVC-sheathed aluminum power cable
High drop, vertical shaft and underwater
Note: Add ZC to the original model of flame-retardant cable of the Company, NH to fire-resistant cable, and WDZN to low-smoke, halogen-free, flame-retardant and fire-resistant cable. 
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable
PVC Sheathed XLPE Insulated High Voltage Construction Used Underground Power Cable

 

3.96mm Ribbon Connector

3.96Mm Ribbon Connector,Single Row Connector,Pc Board Connector,Pc Board Power Connector

YUEQING WEIMAI ELECTRONICS CO.,LTD , https://www.weimaiwafer.com

Posted on