Smart Intergration Temperature Controller-Easy Installation

Model NO.: WNK6T
Condition: New
Customized: Customized
Material: Aluminum Alloy
Output Signal: 4~20m, 4~20mA/Hart, Profibus-PA
Housing Material: Aluminum Alloy
Stability: <0.1/Year
Temperature Drift: 0.05%
Trademark: WNK
Transport Package: 1set in an Individual Box with Foam.
Specification: Accuracy: 0.075 class (Approved MC)
Origin: Anhui, China
HS Code: 90259000
     Smart Intergration Temperature Controller-Easy Installation                           

Wall/Pipe Mounted Temperature Transmitter with LCD display
Our PROFIBUS-PA field bus WNK6T temperature transmitter is approved by PROFIBUS Nutzerorganisation e.V. For temperature sensor we can provide the thermal resister, thermocouple etc usually used in industry, we can also provide special sensor, including high temperature type,high pressure type,health type,with special material or with coating etc sensor. Customized sensor is also acceptable.

Features - Wall/Pipe Mounted Temperature Transmitter with LCD Display
1.  High precision, digital precision up to :±0.01ºC
2.  Long-term drift<0.1/year
3.  Install easily, more flexiable
4.  To reduce the overall cost of installation,maintenance and running.

5.  4~20mA/Hart/Profibus PA output all available
6   Self-diagnostics function

7.  LCD display, Menu-guided operation.


Specification :
Measuring media liquid, gas and steam
Measuring range -270~800 ºC (PT100 thermal resistor)
 0~1300ºC,  (Thermocouple K)
Input Thermocouple, RTD, MV, Resistive sensor
Power supply range 9~45V (9~24V, Ex)
Output signal 4~20mA/Hart/Profibus PA
Digital Accuracy ±0.01ºC, PT100 input
Internal cold end compensation error <0.25ºC±0.1%/10ºC
Temperature drift ±0.05%/10ºCfull scale range
0.1% between-10°C to 60°C
Effect of power supply on range <0.005%/V full-scale range
Long term drift <0.1/year
Ambient temperature                          Ambient temperature  Storage temperature
                     T4           Safe operation(T6)
               -40...85ºC            -40...60ºC -40...95ºC
Protection Class IP66/67
Relative humidity ≤98%, condensation allowed
Electromagnetic compatibility Accordance with EN 61 326

Why Choose us?
1. We are professional manufacturer with own R&D and sales team, with more than 12 years producing experience in transmitters & sensors.    
2. We have strict quality control system, each set product we do temperature compensation and aging test before shipment, so the quality is guaranteed.

Customer specific requirement /ODM/OEM is welcome.






 