UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3

Model NO.: UL719 NM-B
Wire Core Material: Copper or Aluminum
Certification: ISO, CCC, CE, RoHS, UL, VDE, Kema, BV,Psb,ABS,SABS,Gl,Nk
Model: UL719 Mn-B
Brand: Rneda
Rated Voltage: Medium Voltage
Cross Section of Conductor: 14AWG--2AWG
Cores: 1.2.3....Core
Price: Direct Factory Price
Standard.: UL719 & UL83
Model Numb: UL719
Conductor: Pure Copper
Complian with: RoHS
Sample: Provided
Packing: Wooden Drum or Soft Packing
Trademark: RENDA
Transport Package: Standard Export Drum or Soft Packing
Specification: 2+1 CORE
Origin: Tangshan. Hebei. China
HS Code: 8544601400
Model NO.: UL719 NM-B
Wire Core Material: Copper or Aluminum
Certification: ISO, CCC, CE, RoHS, UL, VDE, Kema, BV,Psb,ABS,SABS,Gl,Nk
Model: UL719 Mn-B
Brand: Rneda
Rated Voltage: Medium Voltage
Cross Section of Conductor: 14AWG--2AWG
Cores: 1.2.3....Core
Price: Direct Factory Price
Standard.: UL719 & UL83
Model Numb: UL719
Conductor: Pure Copper
Complian with: RoHS
Sample: Provided
Packing: Wooden Drum or Soft Packing
Trademark: RENDA
Transport Package: Standard Export Drum or Soft Packing
Specification: 2+1 CORE
Origin: Tangshan. Hebei. China
HS Code: 8544601400

Packaging & Delivery

Packaging Details: 100m, 200m, 305m per roll or steel -wooden drum for copper wire
Delivery Time: about 15 days for tw/thw us wire for copper wire


 

Hot sell Building Wire  600V 12-2  Romex  NM-B cable


Product Description

TOP TEN CABLE MANUFACTURER IN CHINA

LARGEST CABLE MANUFACTUER IN NORTH CHINA

ANNUAL EXPORT VOLUME EXCEED 200MILLION USD

WITH UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD'S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS

WITH TUV TYPE TESTING REPORT

WIDE PRODUCTS RANGE

ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONS

CNAS APPROVAL LABROTARY


 

Applications:


Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90ºC. Type NM-B ampacity limitation shall be in accordance with the 60ºC conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.

 

Standards:

Underwriters Laboratories Standards UL-83, UL-719
Federal Specification A-A-59544
ASTM-B3 and B8
ARRA 2009; Section 1605 "Buy American" Compliant


CONSTRUCTION:

Conductors:
Solid 14-10 AWG soft, uncoated copper, per ASTM-B3
Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor:
Soft, uncoated copper per ASTM-B3 and/or ASTM-B8
Jacket:
A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:
14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black


Assembly:

2-conductor construction has the insulated conductors laid parallel with a bare copper ground wire wrapped in paper and laid parallel between the insulated conductors. The entire assembly is wrapped with a paper separator before applying the PVC outer jacket. SuperSlick Elite is available in sizes: 14 AWG, 12 AWG, 10 AWG constructions. 3 and 4 conductor constructions may have the insulated conductors laid parallel or twisted together before applying the PVC outer jacket.


 

Specification:

Size (AWG) Number of Strands

Ground  Wire  

Size

Insulation
Thickness
(in)
Allowable Ampacity
(Amps)*
Outside Diameter
(in)
Approximate Net Weight
(lbs/1000 ft)
PVC Nylon
 14/2 G   Solid   14   0.015   0.004   15   0.170 x 0.390   56 
 12/2 G   Solid   12   0.015   0.004   20   0.160 x 0.450   82 
 10/2 G   Solid   10   0.020   0.004   30   0.210 x 0.493   123 
 8/2 G   7   10   0.030   0.005   40   0.290 x 0.580   185 
 6/2 G   7   10   0.030   0.005   55   0.330 x 0.695   256 
 14/3 G   Solid   14   0.015   0.004   15   0.170 x 0.450   74 
 12/3 G   Solid   12   0.015   0.004   20   0.345   107 
 10/3 G   Solid   10   0.020   0.004   30   0.430   165 
 8/3 G   7   10   0.030   0.005   40   0.555   251 
 6/3 G   7   10   0.030   0.005   55   0.612   352 
 4/3 G   7   8   0.040   0.006   70   0.820   565 
 2/3 G   7   8   0.040   0.006   95   0.945   841 
 **14/4 G & 14/2-2 G   Solid   14   0.015   0.004   12   0.345   90 
 **12/4 G & 12/2-2 G   Solid   12   0.015   0.004   16   0.385   132 
 **10/4 G   Solid   10   0.020   0.004   30   0.540   205 

 

Details show


UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3


Packaging & Shipping

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3

Company information

HeBei huatong wires&cables Group Co.,ltd.It was established in 1993, our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC powercables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We areOEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.

Certification
 

We are one of China top rank cable&wire manufacturer.

Our products meet standards of GB, IEC DIN ASTM, JIS,NF, AS/NZS CSA GOST and so on.

we have obtained ISO9001,ISO14001,OHSAS18001, 

UL,CE,KEMA, TUV, Bureau Veritas, Lloyd,IEC,GL,SA,NK,KR certificates. 

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
Company Information

HeBei huatong wires&cables Group Co.,ltd.It was established in 1993, we are JV with Furukawa(Japanese company) for rubber serious cables and JV with Riken(Japanese company) for elevator cables. Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC powercables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We areOEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.
 

Our Services

1.22 years production experience and 13 years export experience .

2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc

3. OEM service available based on official & legal authorization.

4.Strict quality control system.

5.Rapid delivery and feedback Faster lead time than our competitors.

6.Excellent quality with reasonable price.

7. Strong technical support (technical data, drawing, etc.)

8.Professional teamwork service for you actively.

9.Stock available, Free sample is available.

 

FAQ
 

(1).When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please

call us or tell us in your e-mail so that we will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freight

charge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7

days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

 







 

Packaging & Delivery

Packaging Details: 100m, 200m, 305m per roll or steel -wooden drum for copper wire
Delivery Time: about 15 days for tw/thw us wire for copper wire


 

Hot sell Building Wire  600V 12-2  Romex  NM-B cable


Product Description

TOP TEN CABLE MANUFACTURER IN CHINA

LARGEST CABLE MANUFACTUER IN NORTH CHINA

ANNUAL EXPORT VOLUME EXCEED 200MILLION USD

WITH UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD'S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS

WITH TUV TYPE TESTING REPORT

WIDE PRODUCTS RANGE

ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONS

CNAS APPROVAL LABROTARY


 

Applications:


Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90ºC. Type NM-B ampacity limitation shall be in accordance with the 60ºC conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.

 

Standards:

Underwriters Laboratories Standards UL-83, UL-719
Federal Specification A-A-59544
ASTM-B3 and B8
ARRA 2009; Section 1605 "Buy American" Compliant


CONSTRUCTION:

Conductors:
Solid 14-10 AWG soft, uncoated copper, per ASTM-B3
Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor:
Soft, uncoated copper per ASTM-B3 and/or ASTM-B8
Jacket:
A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:
14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black


Assembly:

2-conductor construction has the insulated conductors laid parallel with a bare copper ground wire wrapped in paper and laid parallel between the insulated conductors. The entire assembly is wrapped with a paper separator before applying the PVC outer jacket. SuperSlick Elite is available in sizes: 14 AWG, 12 AWG, 10 AWG constructions. 3 and 4 conductor constructions may have the insulated conductors laid parallel or twisted together before applying the PVC outer jacket.


 

Specification:

Size (AWG) Number of Strands

Ground  Wire  

Size

Insulation
Thickness
(in)
Allowable Ampacity
(Amps)*
Outside Diameter
(in)
Approximate Net Weight
(lbs/1000 ft)
PVC Nylon
 14/2 G   Solid   14   0.015   0.004   15   0.170 x 0.390   56 
 12/2 G   Solid   12   0.015   0.004   20   0.160 x 0.450   82 
 10/2 G   Solid   10   0.020   0.004   30   0.210 x 0.493   123 
 8/2 G   7   10   0.030   0.005   40   0.290 x 0.580   185 
 6/2 G   7   10   0.030   0.005   55   0.330 x 0.695   256 
 14/3 G   Solid   14   0.015   0.004   15   0.170 x 0.450   74 
 12/3 G   Solid   12   0.015   0.004   20   0.345   107 
 10/3 G   Solid   10   0.020   0.004   30   0.430   165 
 8/3 G   7   10   0.030   0.005   40   0.555   251 
 6/3 G   7   10   0.030   0.005   55   0.612   352 
 4/3 G   7   8   0.040   0.006   70   0.820   565 
 2/3 G   7   8   0.040   0.006   95   0.945   841 
 **14/4 G & 14/2-2 G   Solid   14   0.015   0.004   12   0.345   90 
 **12/4 G & 12/2-2 G   Solid   12   0.015   0.004   16   0.385   132 
 **10/4 G   Solid   10   0.020   0.004   30   0.540   205 

 

Details show


UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3


Packaging & Shipping

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3

Company information

HeBei huatong wires&cables Group Co.,ltd.It was established in 1993, our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC powercables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We areOEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.

Certification
 

We are one of China top rank cable&wire manufacturer.

Our products meet standards of GB, IEC DIN ASTM, JIS,NF, AS/NZS CSA GOST and so on.

we have obtained ISO9001,ISO14001,OHSAS18001, 

UL,CE,KEMA, TUV, Bureau Veritas, Lloyd,IEC,GL,SA,NK,KR certificates. 

UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
UL719 Nonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Nm-B 14/4 G & 14/2-2 G3
Company Information

HeBei huatong wires&cables Group Co.,ltd.It was established in 1993, we are JV with Furukawa(Japanese company) for rubber serious cables and JV with Riken(Japanese company) for elevator cables. Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC powercables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We areOEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.
 

Our Services

1.22 years production experience and 13 years export experience .

2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc

3. OEM service available based on official & legal authorization.

4.Strict quality control system.

5.Rapid delivery and feedback Faster lead time than our competitors.

6.Excellent quality with reasonable price.

7. Strong technical support (technical data, drawing, etc.)

8.Professional teamwork service for you actively.

9.Stock available, Free sample is available.

 

FAQ
 

(1).When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please

call us or tell us in your e-mail so that we will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freight

charge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7

days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

 







 

Servo EMI Filters

Servo Emi Filters,Emi Servo Filters,Servo Motor Emi Filters,Servo Drive Line Filter

Zhejiang Synmot Electrical Technology Co., Ltd , https://www.synmot-electrical.com

Posted on