Brand: Gn
Certification: ISO9001, CE
Quality: World-Class
Price: Competitive
Maintenance: Less and Easy
Technology: Advanced
Experience: More 20 Years
Exported: More 80 Countries
Trademark: GN
Specification: CE SGS
Origin: Shanghai
Brand: Gn
Certification: ISO9001, CE
Quality: World-Class
Price: Competitive
Maintenance: Less and Easy
Technology: Advanced
Experience: More 20 Years
Exported: More 80 Countries
Trademark: GN
Specification: CE SGS
Origin: Shanghai
Brief introduction1. This model intelligent pressure switch is a kind of intelligent digital pressure control products
2. It integrate pressure measurement, LED display and control.
3. It is complete electronic structure, the former adopt pressure sensor which is diaphragm, oil fulfill and piezoresistive type.
4. Application: Measure the gas and liquid. Suit for pump control, tank monitoring, level control, filter plug, monitoring, leakage monitoring. Also it widely used in hydraulic and pneumatic situation, like mechanical facility and process control.
Main features
1.4 digits display the current pressure value, pressure preset switch point and delay switch output.
2. Switch signal can be set it randomly between zero and full scale. The housing have LEB with node action.
3. Easy to observing key-press calibration and the parameter's setting in field. Convenient operation. The overload capacity is 1.2A for 2 channels switch signal output.
4. Analog output (4-20Ma), the measurement range: 0-600bar (Option)
Ordinary type | Anti -explosion | |
Working viscosity | ≤10-3m² / s | ≤10-3m² / s |
Switch element | Micro switch | Micro switch |
Range of anti-explosion | / | Exed II CT6 number:320110395 |
Range of Shell protection | IP65 | IP65 |
Environmental temperature | -15 °C -65°C | -15 °C -65 °C |
Environmental humidity | 5%-95% | 5%-95% |
Life span | 105times circle | 105times circle |
Anti-earthquake | ||
Contact capacity | Vmax=380v Imax=15A | Vmax=380v Imax=5A |
Repeatability error | ≤1.0 % | ≤1.0 % |
Scale number | Scale | Dead zone | Switching frequency | Sensor material |
GK02 | 2-0-2KPa | 30Pa | 10times/sec | 316L |
GK10 | 10-0-10KPa | 0.2KPa | 10times/sec | 316L |
KK02 | 2-0-2KPa | 30Pa | 10times/sec | Ding Qing rubber |
KK10 | 10-0-10KPa | 0.2KPa | 10times/sec | Ding Qing rubber |



Brief introduction
1. This model intelligent pressure switch is a kind of intelligent digital pressure control products
2. It integrate pressure measurement, LED display and control.
3. It is complete electronic structure, the former adopt pressure sensor which is diaphragm, oil fulfill and piezoresistive type.
4. Application: Measure the gas and liquid. Suit for pump control, tank monitoring, level control, filter plug, monitoring, leakage monitoring. Also it widely used in hydraulic and pneumatic situation, like mechanical facility and process control.
Main features
1.4 digits display the current pressure value, pressure preset switch point and delay switch output.
2. Switch signal can be set it randomly between zero and full scale. The housing have LEB with node action.
3. Easy to observing key-press calibration and the parameter's setting in field. Convenient operation. The overload capacity is 1.2A for 2 channels switch signal output.
4. Analog output (4-20Ma), the measurement range: 0-600bar (Option)
Ordinary type | Anti -explosion | |
Working viscosity | ≤10-3m² / s | ≤10-3m² / s |
Switch element | Micro switch | Micro switch |
Range of anti-explosion | / | Exed II CT6 number:320110395 |
Range of Shell protection | IP65 | IP65 |
Environmental temperature | -15 °C -65°C | -15 °C -65 °C |
Environmental humidity | 5%-95% | 5%-95% |
Life span | 105times circle | 105times circle |
Anti-earthquake | ||
Contact capacity | Vmax=380v Imax=15A | Vmax=380v Imax=5A |
Repeatability error | ≤1.0 % | ≤1.0 % |
Scale number | Scale | Dead zone | Switching frequency | Sensor material |
GK02 | 2-0-2KPa | 30Pa | 10times/sec | 316L |
GK10 | 10-0-10KPa | 0.2KPa | 10times/sec | 316L |
KK02 | 2-0-2KPa | 30Pa | 10times/sec | Ding Qing rubber |
KK10 | 10-0-10KPa | 0.2KPa | 10times/sec | Ding Qing rubber |



HP Elitebook 850 g8 keyboard,hp elitebook 850 G8 Palmrest,hp elitebook keyboard
S-yuan Electronic Technology Limited , https://www.syuanelectronic.com