Zinc Coated Steel Wire Strands Galvanized Steel Wire Gsw

Model NO.: GSW
Brand: Rmjt
Product Name: Zinc Coated Steel Wire Strands Galvanized Steel Wi
Standard: BS IEC ASTM DIN and So on
Section Area: 10mm2-1000mm2
Wire Core Material: Zinc Coated Steel Wire
Trademark: RMJT
Transport Package: Wooden Drum or Steel&Wooden Drum
Origin: Henan China
HS Code: 7312100000
Model NO.: GSW
Brand: Rmjt
Product Name: Zinc Coated Steel Wire Strands Galvanized Steel Wi
Standard: BS IEC ASTM DIN and So on
Section Area: 10mm2-1000mm2
Wire Core Material: Zinc Coated Steel Wire
Trademark: RMJT
Transport Package: Wooden Drum or Steel&Wooden Drum
Origin: Henan China
HS Code: 7312100000
Zinc Coated Steel Wire Strands Galvanized Steel Wire GSW

1.Application:

The galvanized steel wire strand is used for overhead ground lines or electrical power transmission lines. Stay or guy wire strands are produced for use with poles, towers, or any Other form of guying.
Construction
concentrically stranded Galvanized steel wire strand available in class "A", "B" and "C" galvanizing, "A" being the least heavy and "C" being the most heavy. Manufactured without welds per ASTM A-363 or with welds per ASTM A-475. Strands are formed to remain substantially in place when severed.

 

2.Standard:
ASTM A475, ASTM A363, BS183:1972

Zinc Coated Steel Wire Strands Galvanized Steel Wire Gsw

3.Specification :
 
Galvanized Steel Wire Stand ASTM-A475
Number of Wires/Dia. Approx.Strand Dia. Siemem Martin Grade High Strength Grade Extra-high Strength Grade Approx.Weight
  Inch mm KN KN KN kg/km
3/2.64 7/32 5.56 10.409 15.569 21.796 131
3/3.05 1/4 6.35 13.523 21.04 29.981 174
3/3.05 1/4 6.35 - - - 174
3/3.30 9/32 7.14 15.035 23.398 33.362 204
3/3.68 5/16 7.94 18.193 28.246 40.479 256
3/4.19 3/8 9.52 24.732 37.187 52.489 328
7/1.04 1/8 3.18 4.048 5.916 8.18 49
7/1.32 5/32 3.97 6.539 9.519 13.078 76
7/1.57 3/16 4.76 8.452 12.677 17.748 108
7/1.65 3/16 4.76 - - - 118
7/1.83 3/16 5.56 11.387 17.126 24.02 145
7/2.03 7/32 6.35 14.012 21.129 29.581 181
7/2.36 1/4 7.14 18.905 28.469 39.812 243
7/2.64 9/32 7.94 23.798 35.586 49.82 305
7/2.77 5/16 7.94 - - - 335
7/3.05 3/8 9.52 30.915 48.04 68.503 407
7/3.68 7/16 11.11 41.591 64.499 92.523 594
7/4.19 1/2 12.7 53.823 83.627 119.657 768
7/4.78 9/16 14.29 69.837 108.981 155.688 991
7/5.26 5/8 15.88 84.961 131.667 188.605 1211
19/2.54 1/2 12.7 56.492 84.961 118.768 751
19/2.87 9/16 12.49 71.616 107.202 149.905 948
19/3.18 5/8 15.88 80.513 124.995 178.819 1184
19/3.81 3/4 19.05 116.543 181.487 259.331 1719
19/4.50 7/8 22.22 159.691 248.211 354.523 2352
19/5.08 1 25.4 209.066 325.61 464.839 2384
37/3.63 1 25.4 205.508 319.827 456.832 3061
37/4.09 11/8 28.58 262 407.457 581.827 4006
37/4.55 11/4 31.75 324.72 505.318 721.502 4833
 
 
 
Galvanized Steel Wire Strand  BS 183 : 1972
Number of wires/Dia. Approx.Strand Dia. Minimum Breaking Load of Strand Approx. Weight
Grade 350 Grade 480 Grade 700 Grade 850 Grade 1000 Grade 1150 Grade 1300
  mm kN kN kN kN kN kN kN kg/km
3/1.80 3.9 2.65 3.66 - - - - - 60
3/2.65 5.7 5.8 7.95 - - - - - 130
3/3.25 7 8.7 11.95 - - - - - 195
3/4.00 8.6 13.2 18.1 - - - - - 295
4/1.80 4.4 3.55 4.9 - - - - - 80
4/2.65 6.4 7.7 10.6 - - - - - 172
4/3.25 7.9 11.6 15.9 - - - - - 260
4/4.00 9.7 17.6 24.1 35.2 - - - - 390
5/1.50 4.1 3.1 4.24 6.18 - - - - 69
5/1.80 4.9 4.45 6.1 8.9 - - - - 95
Mobile radios

Mobile radios,Motorola Two Way Radios,Motorola Talkabout Radios,Motorola Handheld Radio

Guangzhou Etmy Technology Co., Ltd. , https://www.digitaltalkie.com

Posted on