Model NO.: WSP-LPC-18/35
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Waterproof: IP67
Trademark: OEM
Specification: CE, CB
Origin: Shenzhen, Guangdong, China
HS Code: 8504401400
Model NO.: WSP-LPC-18/35
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Waterproof: IP67
Trademark: OEM
Specification: CE, CB
Origin: Shenzhen, Guangdong, China
HS Code: 8504401400
LPC Series: 18-35W Single output LED switching power supply,power LED*LPLC-18: Only 90~132VAC input
*LPHC-18 :Only 180~264VAC input
*LPC-20/35/60: 90~264VAC input
*All sealing glue,internal accord with IP67 rating
*Withstand 300VAC surge input for 5seconds (only LPC-20/35)
*Class 2 isolation, no F.G
*Natural cooling
*Protection function: short circuit,over current,over voltage,over temperature(LPC-20/35 outside)
*Constant current design (constant current mode)
*Class 2 power supply, by LPS(limited power source)test
*100%full load ageing test
*Low cost,high reliability
*Applicable to the adornment of the LED as light source and building lighting, stage lighting and theatical lighting, LED electronic display screen.
*2 years warranty
Series No. | Model No. | Specification | |||||||||||
AC input range | AC inrush Current(Max.) | Over voltage protection | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
LPLC-18 (constant current mode) |
LPLC-18-350 | 90~132VAC | Cold start, 40A/115VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(30cm) | 6~48V,350mA | ±8% | 300mV | 82.0% | 140x32x22 |
LPLC-18-700 | 6~25V, 700mA | ±8% | 250mV | 80.0% | |||||||||
LPHC-18 (constant current mode) |
LPHC-18-350 | 180~264VAC | Cold start, 50A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(30cm) | 6~48V,350mA | ±8% | 300mV | 82.0% | 140x32x22 |
LPHC-18-700 | 6~25V, 700mA | ±8% | 250mV | 80.0% | |||||||||
LPC-20 (constant current mode) |
LPC-20-350 | 90~264VAC | Cold start, 70A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(60cm) | 9~48V,350mA | ±5% | 200mV | 83.0% | 118x35x26 |
LPC-20-700 | 9~30V, 700mA | ±5% | 200mV | 83.0% | |||||||||
LPC-35 (constant current mode) |
LPC-35-700 | 90~264VAC | Cold start, 55A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) | 9~48V,700mA | ±5% | 200mV | 85.0% | 148x40x30 |
LPC-35-1050 | 9~30V, 1050mA | ±5% | 200mV | 85.0% | |||||||||
LPC-35-1400 | 9~24V,1400mA | ±5% | 200mV | 85.0% | |||||||||
LPC-60 (constant current mode) |
LPC-60-1050 | 90~264VAC | Cold start, 60A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) | 9~48V,1050mA | ±5% | 200mV | 87.0% | 162.5x42.5x32 |
LPC-60-1400 | 9~42V, 1400mA | ±5% | 200mV | 85.0% | |||||||||
LPC-60-1750 | 9~34V,1750mA | ±5% | 200mV | 87.0% |
*LPLC-18: Only 90~132VAC input
*LPHC-18 :Only 180~264VAC input
*LPC-20/35/60: 90~264VAC input
*All sealing glue,internal accord with IP67 rating
*Withstand 300VAC surge input for 5seconds (only LPC-20/35)
*Class 2 isolation, no F.G
*Natural cooling
*Protection function: short circuit,over current,over voltage,over temperature(LPC-20/35 outside)
*Constant current design (constant current mode)
*Class 2 power supply, by LPS(limited power source)test
*100%full load ageing test
*Low cost,high reliability
*Applicable to the adornment of the LED as light source and building lighting, stage lighting and theatical lighting, LED electronic display screen.
*2 years warranty
Series No. | Model No. | Specification | |||||||||||
AC input range | AC inrush Current(Max.) | Over voltage protection | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
LPLC-18 (constant current mode) |
LPLC-18-350 | 90~132VAC | Cold start, 40A/115VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(30cm) | 6~48V,350mA | ±8% | 300mV | 82.0% | 140x32x22 |
LPLC-18-700 | 6~25V, 700mA | ±8% | 250mV | 80.0% | |||||||||
LPHC-18 (constant current mode) |
LPHC-18-350 | 180~264VAC | Cold start, 50A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(30cm) | 6~48V,350mA | ±8% | 300mV | 82.0% | 140x32x22 |
LPHC-18-700 | 6~25V, 700mA | ±8% | 250mV | 80.0% | |||||||||
LPC-20 (constant current mode) |
LPC-20-350 | 90~264VAC | Cold start, 70A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | UL,18AGWx2C(60cm) | 9~48V,350mA | ±5% | 200mV | 83.0% | 118x35x26 |
LPC-20-700 | 9~30V, 700mA | ±5% | 200mV | 83.0% | |||||||||
LPC-35 (constant current mode) |
LPC-35-700 | 90~264VAC | Cold start, 55A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) | 9~48V,700mA | ±5% | 200mV | 85.0% | 148x40x30 |
LPC-35-1050 | 9~30V, 1050mA | ±5% | 200mV | 85.0% | |||||||||
LPC-35-1400 | 9~24V,1400mA | ±5% | 200mV | 85.0% | |||||||||
LPC-60 (constant current mode) |
LPC-60-1050 | 90~264VAC | Cold start, 60A/230VAC |
105%~135% Rated output voltage | I/P-O/P:3KVAC | -30ºC~+70ºC | EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 | Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) | 9~48V,1050mA | ±5% | 200mV | 87.0% | 162.5x42.5x32 |
LPC-60-1400 | 9~42V, 1400mA | ±5% | 200mV | 85.0% | |||||||||
LPC-60-1750 | 9~34V,1750mA | ±5% | 200mV | 87.0% |