5kV 133% MV TR-XLPE Aluminum Cable PVC Jacket MV-105 Cable with UL1072
Professional OEM manufacturer
Top ten cable manufactuer in China
Leading ESP cable manufacture , largest Rubber cable manufacturer in China.
With UL,TUV,KEMA,CE,BV,PSB,SABAÂ certifications
With TUVÂ TYPEÂ TESTINGÂ REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications
APPLICATIONS
URD - TRXLPEMLPE insulated cables are designed and manufactured to meet the applications of primary underground distribution suitable for use in wet or dry location, direct burial, underground duct, and exposed to sunlight, To be used at 15kV upto 35kV at conductor temperatures not to exceed 90 deg. C for normal operation.
 SPECIFICATIONS
TRXLPEMLP insulated URD cables meets or exceeds all applicable requirements of thefollowing standards, and guaranteed all cables manufactured and tested under this standards.
- ANSIIICEA S94-649
- AEIC CS-8
- ASTM B-3, ASTM B-8, ASTM B-230 & ASTM B-231
CONSTRUCTION
Conductor :Â Bare aluminium or copper, stranded class B compressed stranding
Conductor Shield :Extruded semi-conducting compound
Insulation :Â TRXLP (TreeRetardant XLPE) or XLPE
Insulation Shield :Â Extruded semi-conducting compound
Concentric Neutral :Â Uncoated copper concentric neutral wires (coated copper are optional)
Encapsulated Jacket :Â Non-conducting LLDPE embedded jacket with extruded red stripes.
PVC or Semi-conducting jacket are available upon request
Data sheet:
Condctor |  Copper Neutral  (1/3) | diameter(inch) |  | Weight (Pounds) | ||||||||
 AWG orMCM |  Stranding |  Number of Wires |
Size AWGÂ (Solid)Â |
 Conductor |  Over |  Over Insul. |
 Over Neutral | Over | Conductor | Concentric |  TotalNo |  Total WithJacket |
Insulation | Shield | Wires | Encaps. Jkt. | Neutral | Jacket | |||||||
 1/0 |  19 wire |  9 |  14 |  0.37 |  1.12 |  1.23 |  1.35 |  1.46 |  325.8 |  119.2 |  659 |  4926 |
 2/0 |  19 wire |  11 |  14 |  0.42 |  1.17 |  1.27 |  1.40 |  1.50 |  410.9 |  146.3 |  775 |  808 |
 3/0 |  19 wire |  14 |  14 |  0.47 |  1.22 |  1.32 |  1.48 |  1.59 |  518.1 |  185.9 |  900 |  923 |
 4/0 |  19 wire |  11 |  12 |  0.53 |  1.28 |  1.38 |  1.54 |  1.71 |  653.3 |  228.0 |  1110 |  1055 |
 250 |  37 wire |  13 |  12 |  0.57 |  1.33 |  1.44 |  1.64 |  1.81 |  771.9 |  282.1 |  1330 |  1292 |
 350 |  37 wire |  12 |  10 |  0.68 |  1.44 |  1.54 |  1.70 |  1.89 |  1081 |  398.0 |  1633 |  1519 |
 500 |  37 wire |  17 |  10 |  0.81 |  1.57 |  1.72 |  1.88 |  2.04 |  1544 |  543.5 |  2002 |  1886 |
 750 |  61 wire |  25 |  10 |  0.99 |  1.76 |  1.93 |  2.11 |  2.28 |  2316 |  801.5 |  2650 |  2289 |
 1000 |  61 wire |  33 |  10 |  1.14 |  1.92 |  2.06 |  2.27 |  2.43 |  3088 |  1058 |  3847 |  2960 |
Certificate
USA is our main market. We have many distributors from USA companies. And we have obtained UL certifications for many products, such as TC cable, DLO cable,RHH/RHW/RHW-2/XHH/XHHW/XHHW-2/SIS, THHN/THHW/THW/THW-2/THWN/THWN-2/TW,SER/SEU/USE/USE-2/MHF, MV-90/MV-105,TC cable,MC cable,DLO,type DG,PV wire,AC Cable,Soow,Welding cable  and so on
Company information:
1 Location:
 Hebei Huatong wires and cables group co., ltd. is Located inTangshan, 100 Km to TianjinXingang sea port, 150Km to the Capital city Beijing China.
2 About Huatong:
Founded in 1993 Registered capital: CNY294 Million Equal to: US$45 Million
Floor space: 220,000 square meter  Employees: 950 Production capacity:US$500Million
3 Production and inspection facility:
Drawing machine : 50 sets
Conductor stranding machine: 30sets
CCV and CV extruding line: 30sets
Insulation and sheath extruding machine: 40sets
Cabling machine: 30sets
Braiding machine:40sets
Other auxiliary machine: 150stes
MV cable partial discharge
equipment: 4sets
Other test machine:100sets
4 Enterprise Principle:
Strengthening Huatong /Benefiting employees /Serving our country and society/Aiming to be a world-renowned enterprise
Our Service:
Â
1.22 years production experience and 13 years export experience .
2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc
3. OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback  Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7. Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
FAQ:
1.How many year have our factory producing power cable?
Our factory produce power cable for 22 years.
2 Hong Long time the customer can get the new price after get your inquiry?
 Usually , It is only one hour is ok for us , because we are factory , we caculate the price by ourself.
3.Which port our factory is near to? Â Â Tianjin , Qingdao port.
4.Which payment term do we accept?
 T/T 30% in advance and balance before shiping the product or L/C 100% at sight both is ok.
5.What about the package for our power cable?
 It is usually packed in strong wooden drum.The drum size is usually:2.0m x 1.25m x 1.12m x 1.4m which suitable for container , we can do it according to customer requirments.
6.How long meter power cable for one wooden drum?
 This is according to power cable's diameter and customer's requirments.
7.How about our delivery time?
  According to your order's quantity , for 1million meters power cable, it is only 25 working days is ok.
8.Do we provide sample for free?
 Yes , we provide the sample to you for free , you only paid for the delivery freight is ok.
Â
Â
Â
5kV 133% MV TR-XLPE Aluminum Cable PVC Jacket MV-105 Cable with UL1072
Professional OEM manufacturer
Top ten cable manufactuer in China
Leading ESP cable manufacture , largest Rubber cable manufacturer in China.
With UL,TUV,KEMA,CE,BV,PSB,SABAÂ certifications
With TUVÂ TYPEÂ TESTINGÂ REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications
APPLICATIONS
URD - TRXLPEMLPE insulated cables are designed and manufactured to meet the applications of primary underground distribution suitable for use in wet or dry location, direct burial, underground duct, and exposed to sunlight, To be used at 15kV upto 35kV at conductor temperatures not to exceed 90 deg. C for normal operation.
 SPECIFICATIONS
TRXLPEMLP insulated URD cables meets or exceeds all applicable requirements of thefollowing standards, and guaranteed all cables manufactured and tested under this standards.
- ANSIIICEA S94-649
- AEIC CS-8
- ASTM B-3, ASTM B-8, ASTM B-230 & ASTM B-231
CONSTRUCTION
Conductor :Â Bare aluminium or copper, stranded class B compressed stranding
Conductor Shield :Extruded semi-conducting compound
Insulation :Â TRXLP (TreeRetardant XLPE) or XLPE
Insulation Shield :Â Extruded semi-conducting compound
Concentric Neutral :Â Uncoated copper concentric neutral wires (coated copper are optional)
Encapsulated Jacket :Â Non-conducting LLDPE embedded jacket with extruded red stripes.
PVC or Semi-conducting jacket are available upon request
Data sheet:
Condctor |  Copper Neutral  (1/3) | diameter(inch) |  | Weight (Pounds) | ||||||||
 AWG orMCM |  Stranding |  Number of Wires |
Size AWGÂ (Solid)Â |
 Conductor |  Over |  Over Insul. |
 Over Neutral | Over | Conductor | Concentric |  TotalNo |  Total WithJacket |
Insulation | Shield | Wires | Encaps. Jkt. | Neutral | Jacket | |||||||
 1/0 |  19 wire |  9 |  14 |  0.37 |  1.12 |  1.23 |  1.35 |  1.46 |  325.8 |  119.2 |  659 |  4926 |
 2/0 |  19 wire |  11 |  14 |  0.42 |  1.17 |  1.27 |  1.40 |  1.50 |  410.9 |  146.3 |  775 |  808 |
 3/0 |  19 wire |  14 |  14 |  0.47 |  1.22 |  1.32 |  1.48 |  1.59 |  518.1 |  185.9 |  900 |  923 |
 4/0 |  19 wire |  11 |  12 |  0.53 |  1.28 |  1.38 |  1.54 |  1.71 |  653.3 |  228.0 |  1110 |  1055 |
 250 |  37 wire |  13 |  12 |  0.57 |  1.33 |  1.44 |  1.64 |  1.81 |  771.9 |  282.1 |  1330 |  1292 |
 350 |  37 wire |  12 |  10 |  0.68 |  1.44 |  1.54 |  1.70 |  1.89 |  1081 |  398.0 |  1633 |  1519 |
 500 |  37 wire |  17 |  10 |  0.81 |  1.57 |  1.72 |  1.88 |  2.04 |  1544 |  543.5 |  2002 |  1886 |
 750 |  61 wire |  25 |  10 |  0.99 |  1.76 |  1.93 |  2.11 |  2.28 |  2316 |  801.5 |  2650 |  2289 |
 1000 |  61 wire |  33 |  10 |  1.14 |  1.92 |  2.06 |  2.27 |  2.43 |  3088 |  1058 |  3847 |  2960 |
Certificate Anisotropic Cylinder Ferrite Magnets Anisotropic Cylinder Ferrite Magnets,Disc Ferrite Magnet,Ferrite Ring Magnet,Ferrite Arc Magnet For Motor HU NAN YUBANG MAGNETIC MATERIAL CO.,LTD , https://www.ybmagnet.com
USA is our main market. We have many distributors from USA companies. And we have obtained UL certifications for many products, such as TC cable, DLO cable,RHH/RHW/RHW-2/XHH/XHHW/XHHW-2/SIS, THHN/THHW/THW/THW-2/THWN/THWN-2/TW,SER/SEU/USE/US