Fuse Holder Box, Fuse Block - Universal
Â
A high quality ENG brand 4 way fuse box
Clear cap, vibration resistant, snap fit cover
Can be secured via 2 pre molded holes
Cable connection via side, plated 6.3mm (standard) blade terminals
Sturdy and robust construction
Dimensions: 87mm Long / 38mm Wide / 42 mm High
Â
Â
 we supply different kinds of SWITCH PANEL, with PC PANEL, with ALUMINIUM PANLE, can install vertically, also we supply different
function of switch panel set, with power Socket, Port USB Socket,
Cigarette Socket, Voltmeter Socket,
Â
 welcome to join us !!
Contact me: Arthur Tsui
Tel: +86 0769 8800 2382
Call me in English, Korean and Chinese
Dongguan Yu Jie Electronics Co., Ltd. | ||||||
Dongguan Yu Jie Electronics Co., Ltd. is mainly dedicated to manufacturing glass tube fuse, ceramic tube fuse, fuse bases, auto blade fuse and others. We have ten years of experience in fuse manufacturing industry, and we have been granted certification of CCC of China, UL of the USA, CSA of Canada, VDE/TUV of Europe, as well as ISO9001. We get a good reputation of quality control and complete facilities. We regard "good customer service, good business reputation and good quality control" ... | ||||||
Basic Information | ||||||
  We are professional in manufacturing all kinds of car switches and boat switches, Car accessaries,Car Volmeter, USB car adaptor, Car fuse, PCBA assembly, electronics components and all kinds of molds for plastic injection industry.   Number of Employees: 101 - 200 People  | ||||||
Trade & Market | ||||||
Western Europe | Mid East | Southeast Asia | ||||
Eastern Europe | North America | |||||
Factory Information | ||||||
Contract Manufacturing: | OEM Service Offered   Design Service Offered  | |||||
Factory certifications: | TUV,CE,IQC,ISO9001,ISO14001,CSA |
1. Dimmable LED High Bay Light
Dimmable LED High Bay Light can be adjusted the brightness of the light, including 0-10v dimmable,Dali dimmable, Triac dimmable and Zigbee dimmable.
0-10V Dimmable:
Used as an early fluorescent dimming system and still used today, 0-10V dimming has been adapted to become a reliable LED dimming control protocol.0-10 V is one of the earliest and simplest electronic lighting control signaling systems; simply put, the control signal is a DC voltage that varies between zero and ten volts. The controlled lighting should scale its output so that at 10 V, the controlled light should be at 100% of its potential output, and at 0 V it should at the lowest possible dimming level.
Dali dimmable:
A basic system could consist of a few light fittings and a switch connected to a DALI group controller. The switch provides on/off control and up/down dimming of the fittings. Minimal configuration is required and ballasts do not need to be individually addressed.A grouped system consists of multiple ballasts individually addressed on a DALI Line Inputs on a Line Controller or a group controller can be configured to provide switching and dimming as required.
SCR Dimmable:
A SCR is a four-layer solid state device that controls current. In the normal [off" state, SCR restricts current to the leakage current. When the gate-to-cathode voltage exceeds a certain threshold, SCR turns [on" and conducts current. A SCR will remain in the [on" state even after gate current is removed so long as current through the device remains above the holding current. Once current falls below the holding current for an appropriate period of time, the device will switch [off". If the gate is pulsed and the current through SCR is below the holding current, SCR will remain in the [off" state.To achieve the dimming effect using SCR dimming technique, first, a RC phase shift is used to delay triggering the gate-to-cathode voltage. There will be a phase-cutting and the Root Mean Squared Voltage VRMS is modified. The symmetric characteristic of DIAC (DIode for Alternating Current) can be used to trigger TRIAC (TRIode for Alternating Current) symmetrically. Then, the dimming effect can be achieved by varying the R1 value that changes the phase angle for conduction.
Zigbee:
Zigbee is a kind of brand-new, focus on low power consumption, low cost, low complexity and low rate of short-range wireless communication technology.Is also a big focus in the embedded application.

Dimmable LED High Bay Light
Dimmable LED High Bay Light,0-10V Dimmable LED High Bay Light,Dali Dimmable LED High Bay Light
Shenzhen Hygea Technology Co.,Ltd. , http://www.hygealedlight.com