ITEM NAME : Copper Wire Braided and Armored Control Cable
Â
See below detail description of the construction, Flame retardant, fire resistance, low smoke zero halogen available.
2. Applications:Â
These cables are suitable for the interconnection between power distribution unit, widely used in controlling signaling protecting and measuring system
Copper conductor |
Copper conductor |
Insulation |
PVC insulation |
Braid |
Copper wire braided |
Armor |
Steel tape armored |
Sheath |
PVC outer sheath |
4. Standard:Â
IEC60502, IEC60332 , other standard such as: BS, DIN, AS/NZS, UL upon request
5. Technical data:
Rated voltage: 450/750V, 0.6/1kv
Max. Operating Temp of Conductor: under normal 70ºC, emergency ( 105ºC), short circuit no more than 5s (160ºC)
Min. Ambient Temperature during installation: 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 12x cable O.D for single core
6. Certificates:
CE, CB, RoHS, KEMA, SABS, UL, TUV, VDE, SON, SAA, SGS applied
7. Core Identification:
Black core with white numbering. OEM Color available, Green/ Yellow earthing core upon request
Types and Specifications
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP |
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP2 |
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
7-61 |
|||
10 |
4-10 |
|||
KVV22 |
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-14 |
|||
KVVR |
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
|||
KYJV |
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJVP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJV22 |
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVP2 |
Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVR |
Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KYJVRP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility and movability are required |
Luxing Factory : our production baseÂ
Company introduction: https://youtu.be/j-bfOk2gCFY
Â
Â
Â
Â
Extruded pvc sheathed,insulation: https://youtu.be/3c93OxsKmBw

Luxing Cable Mainly ProduceÂ
300/500V 450/750V electrical wire | AAC conductor |
600/1000V PVC insulated cable | AAAC conductor |
600/1000V XLPE insulated cable | ACSR conductor |
1.8/3KV to 26/35KV power cable | OPGW |
Armored underground cable | ABC cable |
Control cable and instrumentation cables | Rubber cable |

Strict Quality TestÂ
Packaging & Shipping

Why choose usÂ
1.18 years manufacturing experience
2.Professional international trade team
3.Delivery on time
4.Factory low price and high quality based on advanced technology and high work efficiency
Â
Â
ITEM NAME : Copper Wire Braided and Armored Control Cable
Â
See below detail description of the construction, Flame retardant, fire resistance, low smoke zero halogen available.
2. Applications:Â
These cables are suitable for the interconnection between power distribution unit, widely used in controlling signaling protecting and measuring system
Copper conductor |
Copper conductor |
Insulation |
PVC insulation |
Braid |
Copper wire braided |
Armor |
Steel tape armored |
Sheath |
PVC outer sheath |
4. Standard:Â
IEC60502, IEC60332 , other standard such as: BS, DIN, AS/NZS, UL upon request
5. Technical data:
Rated voltage: 450/750V, 0.6/1kv
Max. Operating Temp of Conductor: under normal 70ºC, emergency ( 105ºC), short circuit no more than 5s (160ºC)
Min. Ambient Temperature during installation: 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 12x cable O.D for single core
6. Certificates:
CE, CB, RoHS, KEMA, SABS, UL, TUV, VDE, SON, SAA, SGS applied
7. Core Identification:
Black core with white numbering. OEM Color available, Green/ Yellow earthing core upon request
Types and Specifications
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP |
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP2 |
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
7-61 |
|||
10 |
4-10 |
|||
KVV22 |
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-14 |
|||
KVVR |
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
|||
KYJV |
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJVP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJV22 |
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVP2 |
Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVR |
Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KYJVRP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility and movability are required |
Luxing Factory : our production baseÂ
Company introduction: https://youtu.be/j-bfOk2gCFY
Â
Â
Â
Â
Extruded pvc sheathed,insulation: https://youtu.be/3c93OxsKmBw

Luxing Cable Mainly ProduceÂ
300/500V 450/750V electrical wire | AAC conductor |
600/1000V PVC insulated cable | AAAC conductor |
600/1000V XLPE insulated cable | ACSR conductor |
1.8/3KV to 26/35KV power cable | OPGW |
Armored underground cable | ABC cable |
Control cable and instrumentation cables | Rubber cable |

Strict Quality TestÂ
Packaging & Shipping

Why choose usÂ
Photoelectric Sensor,Diffuse Reflection Sensor,Retro Reflection Sensor
Photoelectric Sensor ,Light Curtain Sensor Co., Ltd. , http://www.zjelevatorparts.com