The new home was built and stopped for more than a year. It hasn't been capped, and it has arrived in double 11 to prepare for a living room TV. In mid-October, I saw Cool Open's push What Super Superstar 2 went public. . Support HDR and memc dynamic compensation, known as LG hard screen 4k. Although it is 4 color 4k. . Looked under the cpu and memory, also sent the handle and game bag. I still feel that I can handcuffed my hand and placed a deposit, waiting for a double eleven.
No. 11 on the 11th paid on time, more than 10 in the morning, the courier was delivered to the door, and, saying that my home is in a nine-class town, where the national road is not so brutal. . Let the family collect the TV and come back to the box at night. .
Box photo. . Big one. . .
Skip out of the box and assemble. . . I don't think I didn't think I got up and didn't take pictures. . .
Don't ask me what box is in the box underneath the TV. . .
Interface is still quite complete, hdmi2, RF input, usb3.0 and 2.0, audio output coaxial output, AV in.
Configuration diagram
Too lazy, directly affixed to the official map, and, doing really nice. . .
My family's right and left caretaker. . . The moving box can only output 720p. . Make do with watching TV. . .
Remote control, feel OK, but unfortunately not Bluetooth.
Tap the local media to find the 4k TV test picture in the share.
To see it out,, it really is a low-end TV,,, the backlight is very jealous, especially when the monochrome. . .
Start loading app. .
Look at the HDTV content. . .
Hmm, the subtitles are harmonious. .
Installed a so-called game TV app, gelai cloud game. . . The game packs and handles were not sent, and only the assistant handles were used on the phone.
Even queuing up servers. . . You can only see how others play. . .
I found that the speed of wireless connection is not stable, and I have to plug in the network cable after work. .
Finding and LeTV's forcing base is much simpler. . . Too disrespectful is too ugly. . . Wait for the handle to be tossed again. . .
Door Lock Motor Characteristics 1. No direction: don't need to distinguish the door direction, left and right sides, both inside and outside the door, can be universal. (convenient purchase locks and reduce inventory).
2. Power: the power consumption is only equivalent to one 5 of the electric control lock, electric lock, 3 A magnetic lock power to open the door, often consumes 0.27 A. And spiritual lock unlock instantaneous current is less than 0.5 A, reduced the entrance guard, talkback host power consumption.
3. No collision: close the door without collision, reduces the choice of door closers requirements (not necessarily with 65 kg of door closers, door closers are free to choose to suit the door), to solve the building door because the door closers clash of the hydrodynamic force is too high, it is not easy to make the door more deformation, prolong the service life of the body.
4. The voice is light: close the door automatically locked, no noise, solves the noise due to electric control lock itself.
5. Life is long, life is up to 350000 times
Operating temperature range:
Mini Door Lock Motor should be used at a temperature of -10~60℃.
The figures stated in the catalog specifications are based on use at ordinary room temperature catalog specifications re based on use at ordinary room temperature (approximately20~25℃.
If a lock motor is used outside the prescribed temperature range,the grease on the gearhead area will become unable to function normally and the motor will become unable to start.Depending on the temperature conditions ,it may be possible to deal with them by changing the grease of the motor's parts.Please feel free to consult with us about this.
Storage temperature range:
lock motor should be stored ta a temperature of -15~65℃.
In case of storage outside this range,the grease on the gearhead area will become unable to function normally and the motor will become unable to start.
Service life:
The longevity of Door Lock Motor is greatly affected by the load conditions , the mode of operation,the environment of use ,etc.Therefore,it is necessary to check the conditions under which the product will actually be used .The following conditions will have a negative effect on longevity.Please consult with us should any of them apply.
â—Use with a load that exceeds the rated torque
â—Frequent starting
â—Momentary reversals of turning direction
â—Impact loads
â—Long-term continuous operation
â—Forced turning using the output shaft
â—Use in which the permitted overhang load or the permitted thrust load is exceeded
â—A pulse drive ,e.g.,a short break,counter electromotive force,PWM control
â—Use of a voltage that is nonstandard as regards the rated voltage
â—Use outside the prescribed temperature or relative-humidity range,or in a special environment.
â—Please consult with us about these or any other conditions of use that may apply,so that we can be sure that you select the most appropriate model.
when it come to volume production,we're a major player as well .each month,we rurn out 600000 units,all of which are compliant with the rohs directive.Have any questions or special needed, please contact us, we have the engineer group and best sales department to service to you
Looking forward to your inquiry. Welcome to our factory.

Door Lock Motor,Mini Door Lock Motor,Door Lock Dc Motor,Door Lock Gear Motor