Megatro Communication Pole for Square Park

Model NO.: MGP-telecom tower
Condition: According to Client Requirement and Design
We Design by Pls& Tower Software: According to Client Requirement and Design
Accessories 1: Provide Aviation Light
Accessories 2: Provide Bare Copper and Related Fastener
Accessories 3: Provide Earthing Rod
Accessories 4: Provide Cable Tray and Others
Trademark: MEGATRO
Transport Package: Export Package at Client Option
Specification: AS PER CLIENT REQUIREMENTS
Origin: Shandong, China
HS Code: 73082000
Model NO.: MGP-telecom tower
Condition: According to Client Requirement and Design
We Design by Pls& Tower Software: According to Client Requirement and Design
Accessories 1: Provide Aviation Light
Accessories 2: Provide Bare Copper and Related Fastener
Accessories 3: Provide Earthing Rod
Accessories 4: Provide Cable Tray and Others
Trademark: MEGATRO
Transport Package: Export Package at Client Option
Specification: AS PER CLIENT REQUIREMENTS
Origin: Shandong, China
HS Code: 73082000
MEGATRO is professional manufacturer to provide design, fabrication, installation and maintenance for Communication pole for square park. MEGATRO monopole often fabricated by mild steel or high strength steel, such as ASTM A36, ASTM A572 GR50, 65 or other. After fabrication all monopoles are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. MEGATRO Communication pole for square park systems can accommodate a variety of mounts and accessories.


Specification
Height 10-80m
Wind speed 0-180km/m
Material Q235/Q345
Anti-Corrosion Hot dip galvanized or Spray
Connect Way Flange
Delivery time within 20dyas
Service life more than 35years
Work platforn 1-3pc
antenna stand 6-8pc

Communciation tower can be produced according to guyer's requirement, the specification can aslo be ajusted according to buyer's requirement by our engineers, and the antenna stand and platform can be installed in any position as buyer's request, and the quantity of them is also fluctuant due to different clients.
Our company accept 
producing with supplied drawings, and also can design drawing for you as your request.
Other information:
Place of Origin: Qingdao, Shandong, China.
Height: 2 to 50 meters
Availability size: Based on the customer's requirements
Material: Chinese material or as per clients requirement
Fabrication: Based on the customer's drawings and technical requirements
Package: Both parties discuss and agreed before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 1 set
Port of Loading: Qingdao Port
Delivery Time: One month or based on the customer's needs

MEGATRO provide monopole telecom tower design with below requirements

Design Requirements and Basic of Design
MEGATRO TOWERS will guarantee the overall safety of the tower. MEGATRO TOWERS will submit design calculation report for member design of tower and overall structural stability of the structure, which is signed by a charted structural Engineer.
MEGATRO will supply the skeleton to scale, showing the assembly of the structures, the antenna mounting levels, other detail drawings etc.
The calculation method to be adopted for tower design will be decided by MEGATRO TOWERS with the consent of the client.
All materials will comply with British Standard (hereinafter called BS), Japanese Industrial Standard (hereinafter called JIS) or equivalent standards. The permissible stress of the materials will comply with BS, standard by Architectural Institute of Japan (hereinafter call AIJ) or equivalent. The standards adopted for all materials will be stated separately.


General Design Criteria
Mast will be designed based on GB, BS 8100, TIA/EIA-222-G-2006, IS 802 & IS875 or equivalent international standards.
The wind loading on the tower and antennas mounted on it will withstand a ground level wind velocity of 140 Km/h and survival speed of 180 Km/h including with height in accordance with latest BSI CP3: Chapter V: Part 2: British Standard (BS)
Antenna that will be considered when it calculates wind areas will be Six GSM antennas, Two each 600 mm diameter microwave dishes & one 1.2m Ø Microwave plus all the feeders for GSM and MW antennas.
Allowance will be given to the effective windage area of the following:
Feeder runway
Feeders
Platforms and guard rails
Ladder and ladder guards
MEGATRO submit the complete data showing the drag factor from various angles of wind on the antenna offered.
MEGATRO is professional manufacturer to provide design, fabrication, installation and maintenance for Communication pole for square park. MEGATRO monopole often fabricated by mild steel or high strength steel, such as ASTM A36, ASTM A572 GR50, 65 or other. After fabrication all monopoles are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. MEGATRO Communication pole for square park systems can accommodate a variety of mounts and accessories.


Specification
Height 10-80m
Wind speed 0-180km/m
Material Q235/Q345
Anti-Corrosion Hot dip galvanized or Spray
Connect Way Flange
Delivery time within 20dyas
Service life more than 35years
Work platforn 1-3pc
antenna stand 6-8pc

Communciation tower can be produced according to guyer's requirement, the specification can aslo be ajusted according to buyer's requirement by our engineers, and the antenna stand and platform can be installed in any position as buyer's request, and the quantity of them is also fluctuant due to different clients.
Our company accept 
producing with supplied drawings, and also can design drawing for you as your request.
Other information:
Place of Origin: Qingdao, Shandong, China.
Height: 2 to 50 meters
Availability size: Based on the customer's requirements
Material: Chinese material or as per clients requirement
Fabrication: Based on the customer's drawings and technical requirements
Package: Both parties discuss and agreed before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 1 set
Port of Loading: Qingdao Port
Delivery Time: One month or based on the customer's needs

MEGATRO provide monopole telecom tower design with below requirements

Design Requirements and Basic of Design
MEGATRO TOWERS will guarantee the overall safety of the tower. MEGATRO TOWERS will submit design calculation report for member design of tower and overall structural stability of the structure, which is signed by a charted structural Engineer.
MEGATRO will supply the skeleton to scale, showing the assembly of the structures, the antenna mounting levels, other detail drawings etc.
The calculation method to be adopted for tower design will be decided by MEGATRO TOWERS with the consent of the client.
All materials will comply with British Standard (hereinafter called BS), Japanese Industrial Standard (hereinafter called JIS) or equivalent standards. The permissible stress of the materials will comply with BS, standard by Architectural Institute of Japan (hereinafter call AIJ) or equivalent. The standards adopted for all materials will be stated separately.


General Design Criteria
Mast will be designed based on GB, BS 8100, TIA/EIA-222-G-2006, IS 802 & IS875 or equivalent international standards.
The wind loading on the tower and antennas mounted on it will withstand a ground level wind velocity of 140 Km/h and survival speed of 180 Km/h including with height in accordance with latest BSI CP3: Chapter V: Part 2: British Standard (BS)
Antenna that will be considered when it calculates wind areas will be Six GSM antennas, Two each 600 mm diameter microwave dishes & one 1.2m Ø Microwave plus all the feeders for GSM and MW antennas.
Allowance will be given to the effective windage area of the following:
Feeder runway
Feeders
Platforms and guard rails
Ladder and ladder guards
MEGATRO submit the complete data showing the drag factor from various angles of wind on the antenna offered.

Thick Copper PCB are used extensively in power electronic devices and power supply systems. A growing trend in the PCB industry, this unique type of Heavy Copper PCB features a finished copper weight of more than 4oz (140μm), compared to the 1oz (35μm) or 2oz (0μm) copper weight generally found in those with a Standard PCB copper thickness.

The additional copper PCB thickness enables the board to conduct a higher current, achieve good thermal distribution and implement complex switches in a limited space. Other advantages include increased mechanical strength at connector sites, the ability to create a smaller product size by incorporating multiple weights on the same layer of circuitry and the ability to use exotic materials to their maximum capacity with minimal risk of circuit failure.



PCB Manufacture Capabilities

 

Features 

 Capabilities

Layers

1-36 layers

Material

 FR-4, Aluminum, Copper, Polyimide, high frequency (Rogers, PTEE, PI), etc.

PCB Type

FR-4 Standard PCB, Aluminum PCB , Copper-based PCB, HDI PCB , Rigid-Flex PCB, Flex PCB, Thick copper PCB and Rogers PCB, etc.

Board Thickness

0.1mm-6.0mm

Copper Thickness

1/2oz-6oz(18um-210um)

Biggest Board size

600mm*1200mm

Min Tracing/Spacing

0.075mm/0.075mm (3mil/3mil)

Min drilling Hole diameter

0.15mm(6mil), 0.1mm(4mil)-laser drill

Solder Mask

Green, Black, White, Red, Yellow, Blue and Purple, etc.

Silkscreen color

White, Blue, Black, Red, Yellow

Surface finish

HASL Lead free, Immersion Gold (ENIG), Immersion Tin, Immersion Silver, OSP, Carbon oil, etc.

Special Techniques

Impedance Control, Gold Fingers, Blind/Buried vias, Peelable solder mask, Half holes, Via-in-Pad and Countersink hole, etc.


PCB Products Show


PCB Boards


PCB Factory Show


Yifang PCB Factory


Thick Copper PCB

Thick Copper PCB,Thick Copper PCB Board,Copper Thickness Tester PCB,Quality Thick Copper PCB

ZhongFeng Electronic Technology Co., Limited , http://www.1pcbassembly.com

Posted on