Solution to common problems in the detection of weighbridge foundation
If there is something wrong with our platform foundation, how can we solve it? Let me talk about it:
1. Improve the supervision system of the testing market
In order to make the testing market more standardized:
(1) It is necessary to strengthen the control of its contract, that is, to use the relevant inspection mechanism in the contract to limit and stop the illegal acts in the detection market.
(2) It is necessary for the relevant government agencies to carry out standardized management of the markets they detect, to revoke the behaviors or institutions that disrupt their normal development in the market, and to strengthen management of the units or individuals that cause vicious competition, once the existence is confirmed. Acts that trigger vicious competition in the market need to be severely punished according to relevant laws and regulations, so that the entire testing behavior can develop smoothly in a healthy environment.
2. Develop relevant safety protection measures
Through the introduction above, it can be understood that there are many risk factors in the actual platform ground detection work, and the danger needs to use reasonable protection means to ensure the personal safety of the test personnel.
(1) It is necessary for the inspectors to carry out safe operations in accordance with the relevant normative standards, and at the same time, to continuously improve and implement their safety management responsibility system, so that the staff at each stage can clarify their responsibilities and create a perfect safety guarantee system. The safety hazards of the weighbridge foundation inspection process can be effectively avoided.
(2) Strengthen the safety education of inspectors so that they can enhance their awareness of protection in the process of testing.
(3) Before starting the weighbridge foundation test, it is necessary to carry out strict inspection on the construction site of the test site to ensure its standardization and safety. In the process of detecting the foundation of the weighbridge, professional personnel are required to conduct safety patrol for inspection. The correct and standardized operation of the personnel provides guidance to ensure its safety.
3. Application of floor scale foundation test
Taking a shallow foundation pit of a unit as an example, it is mainly to investigate the bearing pressure in the main affected area below the bearing plate in the shallow foundation pit. It is required to use a square or circular bearing plate and ensure the pressure. The diameter of the plate is larger than the maximum particle size in the test soil layer, generally 5 quilts, and the area of ​​the bearing plate is greater than 0.5 m2. In order to keep its structure and humidity within a certain range, it is necessary to Use the coarse sand or medium sand for the leveling operation in the pressed plane, and note that the thickness needs to be less than 20CM. In the process of loading the grade, it is necessary to ensure that it is greater than 8 grades, and ensure the maximum load is 2 times of the design standard. In the process, when the soil around the bearing plate is laterally extruded or the ratio of the settlement amount and the width and diameter of the relevant bearing plate is higher than or equal to 0.06, the loading operation should be stopped in time to ensure the smooth progress of the inspection.
Our professional production and sales:
Truck scale
,
Electronic platform scale
,
Wheelchair scale
,
Roller scale
,
Forklift scale
,
Electronic station
(Welcome to the company website:
Http://
)
Digital scale, Weighting Scale, smart body fat scale
C&Q Technology (Guangzhou) Co.,Ltd. , https://www.gzcqteq.com