This article mainly introduces the installation and setting steps of R2000, I hope this article can be helpful to you.
R2000Network standard IEEE 802.11n
Network protocol TCP/IP protocol
Maximum transmission rate 300Mbps
Transmission rate 2.4GHz300Mbps
Coverage of small and medium-sized households
Frequency range single frequency
Network interface: 5 10/100 fast Ethernet ports (1 WAN and 4 LAN), using auto-sensing technology
Qos support support
WPS function support
WDS function supports WDS wireless bridging denial of service (DoS) attack protection Exposed Host (DMZ) to protect game security
Wireless security WiFi Protected Access (WPA/WPA2—PSK) and WEP dual firewall protection (SPI and NAT firewall) denial of service (DoS) attack protection Exposed Host (DMZ) protection game security
Product size 132.46×108.7×48mm
Product weight 0.163kg
Other performance system requirements Use Ethernet connection to achieve broadband (dedicated line, DSL) Internet services and modem applications; 802.11 b/g/n 2.4 GHz wireless adapter or Ethernet adapter and cable for each computer; Microsoft Windows 7, Windows 8 , Windows Vista, Windows XP, Windows 2000, Mac OS, UNIX or Linux; Microsoft Internet Explorer 5.0, Firefox 2.0 or Safari 1.4 and above; use with N300 wireless USB adapter (WNA3100) for best performance
Router R2000 setup stepsThe first step, set the computer IP address
Before setting the NETGEAR WNR2000 router to go online, you need to set the IP address in the computer's local connection (Ethernet) to be automatically obtained (dynamic IP), as shown in the figure below. If you don't know how to set it, please click to read the article: How to set a computer's dynamic IP address.
Step 2: Connect to NETGEAR WNR2000 router
1. Telephone line Internet access: The user needs to prepare 2 network cables, one network cable is used to connect the ADSL Modem (broadband modem) and the WAN interface of the NETGEAR WNR2000 router; the other network cable is used to connect the computer and the LAN interface of the router (1/2 Any one of /3/4 is fine).
2. Optical fiber Internet access: Users need to prepare 2 network cables, one of which is used to connect the optical modem to the WAN interface of the NETGEAR WNR2000 router, and the other is used to connect the computer to the LAN interface of the router (1/2/3/4 Any one of them is fine).
3. Network cable to access the Internet: users need to prepare a network cable, first plug the network cable provided by the broadband operator into the WAN interface of the NETGEAR WNR2000 router, and then connect the prepared network cable with one end to the computer and the other end to the router LAN interface (any one of 1/2/3/4 is fine).
Pay attention to the problem:
(1) After connecting to the NETGEAR WNR2000 router according to the appeal method, the computer is temporarily unable to access the Internet; when the router is set up, the computer will automatically be able to access the Internet.
(2) Many novice users often ask that after connecting to the NETGEAR WNR2000 router, the computer cannot access the Internet. How can I set up a router? Let me talk about it here: When setting up the router, you do not need a computer to be able to access the Internet. Just connect the router correctly according to the above method, and the computer can enter the router setting interface and set the router to connect to the Internet.
(3) Pay attention to the problem. The network cable used to connect the modem to the router, and the router to the computer must be in normal use. If there is a problem with the network cable, it will cause you to be unable to log in to the setting interface, or you cannot access the Internet after setting.
(4) In the above connection diagram, NETGEAR WNR2000 is replaced with other routers for demonstration; it is convenient for everyone to see the correct connection method more clearly.
The third step, set the NETGEAR WNR2000 router to go online
1. Open the browser on the computer, enter: http:// or http:// in the address bar and press Enter:
2. In the pop-up dialog box, input "user name": admin; input "password": password——>click "OK"
Reminder: The default user name of the NETGEAR WNR2000 router is: admin; the default password is: password.
3. When you first enter the management interface, it will ask if you need to change English to Chinese, click "YES". (WNR2000 supports multi-language packs, which can be selected in the upper right corner)
4. Internet settings
Select menu "Settings" -> "Basic Settings" -> "Does your Internet connection need to log in?" Select: Yes -> "Internet Service Provider" and select PPPoE -> Behind "Login" and "Password" Enter respectively in the blank columns of: broadband account, broadband password -> "Internet IP address" selection: dynamically obtained from ISP -> click "Apply" as shown below:
Pay attention to the problem:
(1) If you have a broadband account and a broadband password, and you need to use a "broadband connection" to access the Internet when you are not using the router, you should follow the above method when setting the NETGEAR WNR2000 router to access the Internet.
(2) If you do not have a broadband account, broadband password, and you are not using a router, you only need to set the computer's IP address to be automatically obtained, and then connect the broadband network cable to the computer's network cable interface, and the computer can go online. When setting the NETGEAR WNR2000 router to access the Internet, please set it as follows: Select the menu "Settings" -> "Basic Settings" -> "Does your Internet connection need to log in?" Select: No -> "Internet IP Address" selection: dynamically obtained from ISP -> click "Apply" as shown in the figure below:
(3) If you don’t have a broadband account or broadband password, but the broadband operator (network administrator) provides an IP address, subnet mask, gateway, DNS; and you need to connect locally to the computer without using a router , Manually fill in the IP address, subnet mask, gateway and DNS provided by the broadband operator (network administrator). Then when setting the NETGEAR WNR2000 router to access the Internet, please set it as follows:
Select the menu "Settings" -> "Basic Settings" -> "Does your Internet connection need to log in" selection: yes "Internet IP address" selection: use a static IP address; then fill in: the IP address provided by the broadband operator, IP subnet mask, gateway IP address -> "Domain Name Server (DNS) Address" selection: use the following DNS server; then fill in the DNS server address provided by the broadband operator -> click "Apply" as shown below:
Pay attention to the problem: IP address, subnet mask, gateway, DNS address are provided by broadband operators. The information filled in above is just a demonstration. Please do not configure your router with the above information, it will not be able to access the Internet.
5. Wireless network settings
Click "Settings" -> "Wireless Settings" -> Set "Wireless Network Identification (SSID)" -> "Mode" selection: maximum 300Mbps -> Select "WPA2-PSK[AES]" -> Settings" Password"——>Click "Apply"
The fourth step, check whether the setting is successful
Select the menu "Maintenance"-"Router Status" to view the connection between the router and the Internet. As shown in the figure, the Internet port obtains the IP address, indicating that the router is successfully connected to the Internet. Then you can surf the Internet!
If the IP address is 0.0.0.0, it means that the router has not dialed successfully. Please check whether the information entered on the basic setting page is correct.
Note the problem: After the setting is successful, it is not necessary to run the previous broadband connection for authentication. Open the webpage directly to surf the Internet!
ConclusionThis is the end of the introduction to the router R2000 setting steps. If there are any deficiencies, please correct me.
Intel I5 Laptop is the one of the important high cpu processors, another ones are i3, i7, i9. We can do 2th, 4th, 5th, 6th, 8th, 10th, 11th or 12th. How to choose a best suitable one? If you do heavier jobs, like interior design, music or video editing, even engineering drawing, etc, 15.6 inch Intel I5 11th Generation Laptop or Intel I5 10th Generation Laptop is a better choice for you. If you focus on portability, Laptop 14 Inch I5 11th generation is a good option. Of course, Intel i7 11th Generation Laptop or 1650 graphics card laptop also available.
Someone may worry the custom one quality, that`s cause that lack of custom Student Laptop knowledge, so just keep reading so that know deep in this field. Frankly speaking, the technical skill is totally mature, no matter hardware or software or craft. You can see nearly no difference when check the oem laptop and brand one in person. To support clients and be confident with our product, provide sample for every clients.
Any other special requirements, you can just contact us freely or email us and share the exact details about what you need, thus right and valuable information sended in 1 working day.
Intel I5 Laptop,Intel I5 11th Generation Laptop,Intel I5 10th Generation Laptop,Laptop 14 Inch I5,Intel I5 Laptop Price
Henan Shuyi Electronics Co., Ltd. , https://www.shuyielectronics.com