Vehicle vision based intelligent driving system

1 Introduction

With the development of society and the growth of the population, more and more cars are entering our daily lives, and traffic is becoming increasingly crowded. Driving a car is a complex activity, and driving for a long time can easily cause fatigue, which can easily lead to traffic accidents. In addition, some engineering vehicles have a harsh environment and high labor intensity during operation, and driving automation of these vehicles is very necessary. In order to make the driving operation of the car simple, safe and comfortable, and free people from the heavy and boring car driving, all countries in the world are actively researching and developing the automatic driving technology.

Countries such as Germany, the United States, and Japan have conducted active research in the field of automotive autonomous driving and have achieved great results. The School of Mechanical and Electrical Engineering of National Defense University of Science and Technology of China has been conducting research on the automatic driving technology of automobiles. The unmanned "Red Flag" CA7460 jointly developed by the First Automobile Group Corporation was successfully tested in Changsha, Hunan Province in June 2003. 130KM / h (the highest level in the United States 100KM / h, Germany 120 KM / h), the maximum speed of 170 KM / h, with safe overtaking ability. However, their system mainly relies on vehicle radar, infrared range finder and image sensor to identify the road surface environment. The obtained road environment information is not rich enough to meet the requirements of intelligent driving, so these systems can only be in the road. Good on-highway applications, unable to adapt to low-grade roads and urban roads with poor road conditions.

Vision is an important function of human beings to observe the world and understand the world. About 75% of the information that humans obtain from the outside world comes from the visual system. In particular, 90% of the information needed for driver driving comes from vision. In the current environment sensing means adopted by automobile assisted driving, visual sensors can obtain higher, more accurate and richer road structural environment information than ultrasound, laser radar and the like. With the development of computer technology and the maturity of image processing/recognition technology, machine vision technology has been greatly developed. It is widely used in 3D measurement, 3D reconstruction, virtual reality, moving target detection and target recognition. In the automatic driving of the car, a premise problem is the identification of the road and the distance between the vehicle and the obstacle, and the speed detection. It is only possible to control the driving of the car by solving this problem. Machine vision technology combines 3D measurement and image recognition technology.

At present, the research of machine vision in the field of intelligent robots is in full swing: Klaus Fleischer et al. proposed the detection and tracking of fixed objects based on machine vision in urban road infrastructure; D. Brzakovie et al. proposed the application of road edge detection in mobile robot navigation; O. Djekoune et al. proposed a neural network based visual guided robot navigation. These findings have important implications for the application of machine vision in smart driving.

In this paper, machine vision technology is applied to the automatic driving of vehicles as the main road condition sensing means, which provides a different perspective for the intelligent driving of vehicles.

2, machine vision technology

Since the introduction of MARR visual computing theory, machine vision technology has developed rapidly and is one of the fastest growing technologies in the field of intelligent driving. It is also one of the main research directions in the field of intelligent driving.

2.1 The basic principles of machine vision

Obtaining the distance of each point in the scene from the camera is one of the important tasks of the stereo vision system. The distance of each point in the scene relative to the camera can be represented by a depth map. The machine vision system mainly relies on the dual (multiple) CCD to acquire two (multiple) images at different spatial positions, and the depth map and imaging geometry of the two (multiple) images are used to generate the depth map (shown in Figure 1). ).

This article takes a relatively simple and commonly used binocular CCD vision system as an example, and its geometric relationship is shown in the figure. It consists of two identical CCD cameras (cameras), the two image planes are on the same plane, the axes of the two cameras (cameras) are parallel to each other, and the x-axis coincides with the distance between the cameras in the lower x direction. For the ultimate distance B.

Vehicle vision based intelligent driving system

Figure 1 Binocular stereo vision geometric model

In the figure, the projection points of the scene point P in the left and right image planes are P left and P right, respectively, assuming that the origin of the coordinate system coincides with the center of the left lens, and the similar triangles PMCl and PlLCl are obtained:

Vehicle vision based intelligent driving system (1)

Similarly, from the similar triangles PNCr and PlRCr, we get:

Vehicle vision based intelligent driving system (2)

Combine the above two formulas:

Vehicle vision based intelligent driving system (3)

Where F is the focal length.

It can be seen from the above that the depth information in various scenes can be realized by calculating the parallax. An important prerequisite for accurate calculation of parallax in the machine vision system is the ability to find conjugate pairs of projection points in the left and right image pairs (the projection points of the same point in different images in the scene are called conjugate pairs). That is, stereo matching. The matching methods mainly include edge feature matching, region feature matching and phase matching. Stereo matching is an important direction in machine vision research. There are many useful research results in this respect. O.Djekoune et al. proposed a new algorithm to improve the matching speed and accuracy of stereo pairs by applying neural network.

2.2 Machine vision technology in smart driving applications

In the application of machine vision technology in intelligent driving, machine vision technology must have the characteristics of real-time, robustness and practicality. Real-time requirements require that the data processing of the machine vision system must be synchronized with the high-speed driving of the vehicle; robustness requires intelligent vehicles to different road environments such as highways, city roads, ordinary roads, etc., complex road environments such as road width , color, texture, curve, slope, potholes, obstacles and traffic flow, all kinds of weather, sunny, rain, snow, fog, etc. have good adaptability; practicality means that intelligent vehicles can be accepted by ordinary users.

Currently, machine vision is mainly used for path identification and tracking. Compared with other sensors, machine vision has the advantages of rich information detection, contactless measurement and three-dimensional modeling of road environment, but the data processing is extremely large, and there are system real-time and stability problems. Computer hardware, research new algorithms to solve. With the rapid development of computer technology and image processing technology, the three-dimensional reconstruction of the road environment provides powerful information for high-speed intelligent driving of vehicles, and it has practical feasibility in the near future.

The basic principle of road recognition for machine vision is that the CCD image gray value and the image texture and optical flow of the road pavement environment (white road signs, edges, road color, potholes, obstacles, etc.) are different. According to this difference, the required path image information such as azimuth deviation, lateral deviation, position of the vehicle in the road, and the like can be obtained after image processing. Combining this information with the vehicle's dynamic equations can form a mathematical model of the vehicle control system.

Plug-in Terminal Block

Plug-in Terminal Block

It is made of two parts of plug-in connection. One part compresses the wire and then plugs it into the other part, which is welded to PCB. The mechanical principle of the connection bottom and the anti vibration design ensure the long-term airtight connection of the product and the use reliability of the finished product. The two ends of the socket can be equipped with lugs, which can protect the lug to a large extent and prevent the poor arrangement of the lug.

At the same time, this kind of socket design can ensure that the socket can be inserted into the matrix correctly.
The socket can also have assembly and locking positions. The assembly buckle can play a more stable role in fixing to the PCB, and the lock buckle can lock the mother body and the socket after the installation. Various socket designs can be matched with different insertion methods of the parent, such as: horizontal, vertical or inclined to printed circuit board, etc., and different ways can be selected according to the requirements of customers. Either metric wire gauge or standard wire gauge can be selected, which is the most popular terminal type in the market at present.

Plug-in Terminal Block

ShenZhen Antenk Electronics Co,Ltd , https://www.atkconnectors.com

Posted on