100W Warehouse Industrial UFO LED High Bay Light
Nominal Power | Â | 100W | 160W | 200WÂ | |||
LED Working Current | 100 mAÂ | 83 mA | 70 mA | ||||
LED Brand &Â Qty. | LUMILEDS 3030 2DÂ Â 152 pcs | LUMILEDS 3030 2DÂ Â 240 pcs | LUMILEDS 3030 2DÂ Â 304 pcs | ||||
Driver Brand | Meanwell | ||||||
Lumen Output | Â | 14000 lm | 22400 lm | 28000 lm | |||
Luminaire Efficacy |
140 lm /w | 140 lm /w | 140 lm /w | ||||
Input Voltage | 100-240/277V ACÂ Â 50/60Hz | ||||||
Light Distributions |  | 60° (PC Lens);  110 °(Tempered Glass) | |||||
Color Temperature | Â | 3000K, 4000K, 5000K, 5700K | |||||
Surge Protection Device(SPD) | 10KV | ||||||
Dimming 0(1)-10V | NO | YES | YES | ||||
Rating | ClassI, IP65, IK08 | ||||||
CRI | > 70 | ||||||
Power Factor | > 0.95 | ||||||
Power Efficiency | > 90% | ||||||
Lifetime(h) | >100,000 (L70) | ||||||
Material | Housing: Die-cast aluminum; Lens: Tempered glass /PC | ||||||
Working  Environment |
-40 ºC ~ +50 ºC, 10%~90%RH | ||||||
Storage Temperature | -40 ºC ~ +50 ºC | ||||||
Fixture Info. | 350*350*193mm; 4.9kg | 350*350*193mm; 5.4kg | 350*350*193mm; 6.0kg | ||||
Packing Info. | 365*365*210mm; 6.4kg | 365*365*210mm; 6.9kg | 365*365*210mm; 7.5kg |



Major advantages of UFO high bay light:Â
1. Lumileds 3030 LEDs, luminaire efficacy is more than 130lm/w.
2. Meanwell driver with dimming functions and 4KV surge protection.Â
Â
3. 5Â years warranty.
Â
4. Simple ring structure design,multy mounting ways.
Â
5. Small and light body which saves much shipping cost.

Â
Â
Â
Â

100W Warehouse Industrial UFO LED High Bay Light
Nominal Power | Â | 100W | 160W | 200WÂ | |||
LED Working Current | 100 mAÂ | 83 mA | 70 mA | ||||
LED Brand &Â Qty. | LUMILEDS 3030 2DÂ Â 152 pcs | LUMILEDS 3030 2DÂ Â 240 pcs | LUMILEDS 3030 2DÂ Â 304 pcs | ||||
Driver Brand | Meanwell | ||||||
Lumen Output | Â | 14000 lm | 22400 lm | 28000 lm | |||
Luminaire Efficacy |
140 lm /w | 140 lm /w | 140 lm /w | ||||
Input Voltage | 100-240/277V ACÂ Â 50/60Hz | ||||||
Light Distributions |  | 60° (PC Lens);  110 °(Tempered Glass) | |||||
Color Temperature | Â | 3000K, 4000K, 5000K, 5700K | |||||
Surge Protection Device(SPD) | 10KV | ||||||
Dimming 0(1)-10V | NO | YES | YES | ||||
Rating | ClassI, IP65, IK08 | ||||||
CRI | > 70 | ||||||
Power Factor | > 0.95 | ||||||
Power Efficiency | > 90% | ||||||
Lifetime(h) | >100,000 (L70) | ||||||
Material | Housing: Die-cast aluminum; Lens: Tempered glass /PC | ||||||
Working  Environment |
-40 ºC ~ +50 ºC, 10%~90%RH | ||||||
Storage Temperature | -40 ºC ~ +50 ºC | ||||||
Fixture Info. | 350*350*193mm; 4.9kg | 350*350*193mm; 5.4kg | 350*350*193mm; 6.0kg | ||||
Packing Info. | 365*365*210mm; 6.4kg | 365*365*210mm; 6.9kg | 365*365*210mm; 7.5kg |



Major advantages of UFO high bay light:Â
1. Lumileds 3030 LEDs, luminaire efficacy is more than 130lm/w.
2. Meanwell driver with dimming functions and 4KV surge protection.Â
Â
3. 5Â years warranty.
Â
4. Simple ring structure design,multy mounting ways.
Â
5. Small and light body which saves much shipping cost.

Â
Â
Â
Â
Health Care heat film is mainly used for Far Infrared Sauna Room heat film,health care product, Body Heat Film ,eye massage thin heated element,Infrared Heating Jacket, Flexible Heating Flim for ski suit,Heating Flim For Diving Suit.
we are a professional and leader Chinese exporter of heat film,Customization options (for example: SMT components, flex cable and connectors) can provide the perfect complete solution that can significantly reduce assembly time and increase productivity.Providing a variety of complex shapes design, and different power designs. Membrane in the same piece electrically heated heating circuit can be designed and holding circuit,we are looking forward to your cooperation.
Health Care Heating Film,Carbon Heating Film,Infrared Heat Film,Infared Heating
ShenZhen XingHongChang Electric CO., LTD. , http://www.xhc-heater.com