- Model NO.: 95mm2 120mm2
- Conductor Type: Stranded
- Conductor Material: Aluminum
- Insulation Material: XLPE
- Range of Application: Mine
- Brand: Huatong
- Factory Area: 100000mm2
- Trademark: Huatong
- Specification: Aluminium 1350 and XLPE
- HS Code: 8544601200
- Type: Insulated
- Application: Overhead, Underground
- Sheath Material: Crosslinking
- Material Shape: Round Wire
- Certification: ISO9001, CCC
- Standard: ANSI/Icea S-66-524 or IEC
- QC: 25
- Transport Package: Wood Drum or Steel- Wood Drum
- Origin: China
Description
XLPE insulated or covered aerial cable without or with conductor screen, the phase conductor may be AAC or AAAC or ACSR or Copper.
Â
Operating Characteristics
Operating voltage: 10kV 15kv 24kv 25kv 35kv
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
Single core cable: not less than 20 times of the diameter of cable
Multi-core cable: not less than 15 times of the diameter of cable
Â
Application
XLPE insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission and distribution, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
Â
Manufacturing Standards
GB/T 14049-2008, IEC 60502-2,  ICEA S-66-524 / MEA
IF YOUR HAVE ANY INTERESTED PRODUCTS, PLS FEEL FREE TO CONTACT OUR SALES TEAM.
Â
Â
Conductor | Thickness of conductor  Screen mm  (Average) | Thickness  of  insulation mm  (Nominal) |
Thickness  of  Jacket mm  (Nominal) |
Overall Diameter  Mm (Approx.) |
Conductor resistance at 20°C  Ω/km (Max.) |
Insulation resistance at 15.6°C  MΩ*km (Min.) |
Conductor Weight | Breaking strength  N (Min) |
Current rating in free air at 40°C ambient A  |
Cable weight  Kg/km (Approx.) |
|||
Cross- sectional area mm2 (Nominal) |
Number  of o  wires  (Min.) |
Diameter  of i conductor mm (Approx.) |
|||||||||||
35 | 6 | 6.88 | 0.3 | 3.175 | 3.175 | 21.0 | 0.868 | 2580 | 94 | 5591 | 150 | 381 | Â |
50 | 6 | 7.92 | 0.3 | 3.175 | 3.175 | 22.0 | 0.641 | 2380 | 128 | 7313 | 181 | 438 | Â |
70 | 12 | 9.55 | 0.3 | 3.175 | 3.175 | 23.5 | 0.443 | 2126 | 185 | 10420 | 225 | 527 | Â |
95 | 15 | 11.27 | 0.3 | 3.175 | 3.175 | 25.5 | 0.320 | 1913 | 256 | 14098 | 275 | 636 | Â |
120 | 15 | 12.68 | 0.3 | 3.175 | 3.175 | 27.0 | 0.253 | 1759 | 324 | 18518 | 319 | 734 | Â |
150 | 15 | 14.05 | 0.3 | 3.175 | 3.175 | 28.0 | 0.206 | 1648 | 398 | 22457 | 362 | 838 | Â |
185 | 30 | 15.75 | 0.3 | 3.175 | 3.175 | 30.0 | 0.164 | 1521 | 500 | 58974 | 418 | 970 | Â |
240 | 30 | 18.23 | 0.3 | 3.175 | 3.175 | 32.5 | 0.125 | 1367 | 655 | 37506 | 497 |
Gas Stove,Gas Burner,Gas Cooker
Stainless Steel Gas Hob,Tempered Glass Gas Hob Co., Ltd. , http://www.nsgasstove.com