Model NO.: YJ6110
Starting Mode: Variable Frequency Starting
Certification: ISO9001, CCC, Ce & UL
Brand: OEM
Place of Origin: China (Mainland)
Power: 78W or as Customers′ Requirement
Rotation: Cw
Voltage: 110V to 240V
Frequency: 50/60Hz
in/Outlet Direction: Can Be Customized to Your Demands
Frame Style: C-Frame Motors
Winding Wire: Copper
Shaft Diameter: 4mm, 5mm, 6mm
Insulation Class: E, B, F, H
Trademark: OEM
Transport Package: 40PCS Per Cartons,
Specification: CCC, CE, UL
Origin: China (Mainland)
HS Code: 8501109990
Model NO.: YJ6110
Starting Mode: Variable Frequency Starting
Certification: ISO9001, CCC, Ce & UL
Brand: OEM
Place of Origin: China (Mainland)
Power: 78W or as Customers′ Requirement
Rotation: Cw
Voltage: 110V to 240V
Frequency: 50/60Hz
in/Outlet Direction: Can Be Customized to Your Demands
Frame Style: C-Frame Motors
Winding Wire: Copper
Shaft Diameter: 4mm, 5mm, 6mm
Insulation Class: E, B, F, H
Trademark: OEM
Transport Package: 40PCS Per Cartons,
Specification: CCC, CE, UL
Origin: China (Mainland)
HS Code: 8501109990
YJ61 draught fan with accessories
1. Stator size is optional
2. Safe, reliable, low noise, good starting, long life
3. Strong power
Rated voltage 110~120V/220~240V-50/60Hz
Typical used: Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse
1. A of size: 30mm
2. Power: 78W
3. Shafe dia: 4mm
4. Thermal protection, reliable, low noise, good starting
NOTED:
A OF SZIE AND Transmission Shaft can be made according to customer's requirement
Typical used: Hospital nebulizer, Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse
Â
YJ61 | Â | Â | Â | Â | Â | Â |
 |  |  |  |  |  |  |
TYPICAL APPLICATION | Â | Â | Â | Â | Â | |
HEATER , EXHAUST FAN,REFRIGERATOR,ETC | Â | Â | Â | |||
SPECIFICATION | Â | Â | Â | Â | Â | |
MODEL | A OF SIZE | SHAFT DIA | VOLT | POWER | ROTATION | SPEED RATED |
YJ6110 | 10MM | 3.165MM | 110-240V | 6W | CW | 2600RPM |
 |  |  |  |  |  |  |




Our company FAQ for you
(1) Q: What kind motors you can provide?
A:For now,we mainly provide Kitchen Hood Motor,DC Motor,Gear Motor,Fan Motor Refrigerator Motor,Hair Dryer Motor Blender Motor Mixer Motor,
Shade Pole Motor,Capacitor Motor,BLDC Motor PMDC Motor,Synchronous Motor,Stepping Motor etc.
(2) Q: Is it possible to visit your factory
A: Sure. But please kindly keep us posted a few days in advance. We need to check our
schedule to see if we are available then.
(3) Q: Can I get some samples
A: It depends. If only a few samples for personal use or replacement, I am afraid it will
be difficult for us to provide, because all of our motors are custom made and no stock
available if there is no further needs. If just sample testing before the official order and
our MOQ, price and other terms are acceptable, we'd love to provide samples.
(4) Q: Is there a MOQ for your motors?
A: Yes. The MOQ is between 1000~10,000pcs for different models after sample approval.
But it's also okay for us to accept smaller lots like a few dozens, hundreds or thousands
For the initial 3 orders after sample approval.For samples, there is no MOQ requirement. But the less the better (like no more than 5pcs) on condition that the quantity is enough in case any changes needed after initial testing.
ABOUT US
Ritscher group was set up in 2006.we always focus on micro-motors for household electrical appliance and industry appliance since setting up.currently we have two professional micro-motor factories in China  which severally located in Ningbo city and Foshan city.it has an area of 25,000 square meters plants and more than 300 employees, annual output  is 3 million pcs and has 5 million pcs annual producing capacity.after several years development,we had built a great reputation in the market and got more and more customers'  trust in the world.
We started from shaded pole motors  at beginning, up to now,our product  included of shaded pole motors,synchronous motors,stepping motors ,capacitor motors, BLDC motors, DC motors and compressors. Our product  are widely used for making refrigerators, freezers, micro-wave ovens, air warmers, air exhausters, ventilators,ovens, air filter, massage machines and many other equipments.
As a realiable quality guaranty,Ritscher has complete R&D departement,QC department,producing department,purchase department etc. has perfect producing equipment like Aluminum diecasting, Zinc diecasting, Sheet metal stamping, Plastic Injection Molding etc. also test/ detection device like multiplex temp measuring device, performance parameter inspection device, Phenol peptide solution pinhole tester,Anechoic room etc.
Â
Endeavoring to provide the best product and service to customers,we always do the most effort to become an outstanding manufacturer of micro motors.
Ritscher is always willing to establish sincere business relationship with friends from all over the world.
Welcome contact with us!
Â
Take ritscher ,enjoy modern life!
Â
YJ61 draught fan with accessories
1. Stator size is optional
2. Safe, reliable, low noise, good starting, long life
3. Strong power
Rated voltage 110~120V/220~240V-50/60Hz
Typical used: Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse
1. A of size: 30mm
2. Power: 78W
3. Shafe dia: 4mm
4. Thermal protection, reliable, low noise, good starting
NOTED:
A OF SZIE AND Transmission Shaft can be made according to customer's requirement
Typical used: Hospital nebulizer, Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse
Â
YJ61 | Â | Â | Â | Â | Â | Â |
 |  |  |  |  |  |  |
TYPICAL APPLICATION | Â | Â | Â | Â | Â | |
HEATER , EXHAUST FAN,REFRIGERATOR,ETC | Â | Â | Â | |||
SPECIFICATION | Â | Â | Â | Â | Â | |
MODEL | A OF SIZE | SHAFT DIA | VOLT | POWER | ROTATION | SPEED RATED |
YJ6110 | 10MM | 3.165MM | 110-240V | 6W | CW | 2600RPM |
 |  |  |  |  |  |  |




Our company FAQ for you
(1) Q: What kind motors you can provide?
A:For now,we mainly provide Kitchen Hood Motor,DC Motor,Gear Motor,Fan Motor Refrigerator Motor,Hair Dryer Motor Blender Motor Mixer Motor,
Shade Pole Motor,Capacitor Motor,BLDC Motor PMDC Motor,Synchronous Motor,Stepping Motor etc.
(2) Q: Is it possible to visit your factory
A: Sure. But please kindly keep us posted a few days in advance. We need to check our
schedule to see if we are available then.
(3) Q: Can I get some samples
A: It depends. If only a few samples for personal use or replacement, I am afraid it will
be difficult for us to provide, because all of our motors are custom made and no stock
available if there is no further needs. If just sample testing before the official order and
our MOQ, price and other terms are acceptable, we'd love to provide samples.
(4) Q: Is there a MOQ for your motors?
A: Yes. The MOQ is between 1000~10,000pcs for different models after sample approval.
But it's also okay for us to accept smaller lots like a few dozens, hundreds or thousands
For the initial 3 orders after sample approval.For samples, there is no MOQ requirement. But the less the better (like no more than 5pcs) on condition that the quantity is enough in case any changes needed after initial testing.
ABOUT US
Ritscher group was set up in 2006.we always focus on micro-motors for household electrical appliance and industry appliance since setting up.currently we have two professional micro-motor factories in China  which severally located in Ningbo city and Foshan city.it has an area of 25,000 square meters plants and more than 300 employees, annual output  is 3 million pcs and has 5 million pcs annual producing capacity.after several years development,we had built a great reputation in the market and got more and more customers'  trust in the world.
We started from shaded pole motors  at beginning, up to now,our product  included of shaded pole motors,synchronous motors,stepping motors ,capacitor motors, BLDC motors, DC motors and compressors. Our product  are widely used for making refrigerators, freezers, micro-wave ovens, air warmers, air exhausters, ventilators,ovens, air filter, massage machines and many other equipments.
As a realiable quality guaranty,Ritscher has complete R&D departement,QC department,producing department,purchase department etc. has perfect producing equipment like Aluminum diecasting, Zinc diecasting, Sheet metal stamping, Plastic injection molding etc. also test/ detection device like multiplex temp measuring device, performance parameter inspection device, Phenol peptide solution pinhole tester,Anechoic room etc.
Â
Endeavoring to provide the best product and service to customers,we always do the most effort to become an outstanding manufacturer of micro motors.
Ritscher is always willing to establish sincere business relationship with friends from all over the world.
Welcome contact with us!
Â
Take ritscher ,enjoy modern life!
Â
Cold Shrink Tubing,Cold Shrink Sleeving ,Heat Shrink Tape ,Shrink Wrap Machine
Cable Sleeve Co., Ltd. , http://www.nbshrinktubing.com