4 Core Fire Resistance Security Alarm Cable
Â
Alarm Cable/Control Cable
- Conductor Material: CU/CCA
- Insulation Material: PVC
- Insulation Diameter: 1mm/1.5mm
- Drian Wire Material: N/A
- Jacket Material: PVC
- Signal Shield: Al/Polyester Foil; Coverage>100%.
- Double Fully Shield: Al/Polyester Foil + Tinned Copper Braid
Fire Cable/Fire Alarm Cable
- Conductor Material: CU
- Insulation Material: PVC
- Insulation Diameter: 1.8mm/2.15mm/2.40mm/2.80mm
- Drian Wire Material: 0.5mm CU
- Jacket Material: PVC
- Signal Shield: Al/Polyester Foil; Coverage>100%
Alarm Cable/Control Cable
Â
Cable Size |
Specification |
Overall Diameter |
2x0.22mm² |
2x7/0.20 |
3.0mm |
4x0.22mm² |
4x7/0.20 |
3.5mm |
6x0.22mm² |
6x7/0.20 |
4.1mm |
8x0.22mm² |
8x7/0.20 |
4.5mm |
10x0.22mm² |
10x7/0.20 |
5.2mm |
12x0.22mm² |
12x7/0.20 |
5.6mm |
14x0.22mm² |
14x7/0.20 |
5.8mm |
20x0.22mm² |
20x7/0.20 |
6.8mm |
2x0.50mm² |
2x16/0.20 |
4.5mm |
4x0.50mm² |
4x16/0.20 |
5.2mm |
6x0.50mm² |
6x16/0.20 |
6.0mm |
8x0.50mm² |
8x16/0.20 |
6.8mm |
10x0.50mm² |
10x16/0.20 |
7.6mm |
12x0.50mm² |
12x16/0.20 |
8.0mm |
Fire Cable/Fire Alarm Cable
Â
Cable Size |
Specification |
Overall Diameter |
2x0.5mm² |
2x0.8mm |
4.80mm |
2x2x0.5mm² |
4x0.8mm |
6.00mm |
2x1.0mm² |
2x1.15mm |
5.30mm |
2x2x1.0mm² |
4x1.15mm |
6.60mm |
2x1.5mm² |
2x1.40mm |
5.90mm |
2x2x1.5mm² |
4x1.40mm |
7.20mm |
2x2.5mm² |
2x1.80mm |
6.80mm |
2x2x2.5mm² |
4x1.80mm |
8.00mm |
Application:
For internal wiring in class 2 circuits of electronic equipment or TV game data transmission.
Â
Packing:
1)Packing Lengths: 100m/roll, 200m/roll, 305m/roll, 100yard/roll, 200yard/roll, 300yard/roll.
2) Inner packing:Roll, Wooden reel, plastic reel, and paper reel.
3) Outer packing: Carton box, pull out box, pallet available.
4) Other packing available according to client's request.

Â
4 Core Fire Resistance Security Alarm Cable
Â
Alarm Cable/Control Cable
- Conductor Material: CU/CCA
- Insulation Material: PVC
- Insulation Diameter: 1mm/1.5mm
- Drian Wire Material: N/A
- Jacket Material: PVC
- Signal Shield: Al/Polyester Foil; Coverage>100%.
- Double Fully Shield: Al/Polyester Foil + Tinned Copper Braid
Fire Cable/Fire Alarm Cable
- Conductor Material: CU
- Insulation Material: PVC
- Insulation Diameter: 1.8mm/2.15mm/2.40mm/2.80mm
- Drian Wire Material: 0.5mm CU
- Jacket Material: PVC
- Signal Shield: Al/Polyester Foil; Coverage>100%
Alarm Cable/Control Cable
Â
Cable Size |
Specification |
Overall Diameter |
2x0.22mm² |
2x7/0.20 |
3.0mm |
4x0.22mm² |
4x7/0.20 |
3.5mm |
6x0.22mm² |
6x7/0.20 |
4.1mm |
8x0.22mm² |
8x7/0.20 |
4.5mm |
10x0.22mm² |
10x7/0.20 |
5.2mm |
12x0.22mm² |
12x7/0.20 |
5.6mm |
14x0.22mm² |
14x7/0.20 |
5.8mm |
20x0.22mm² |
20x7/0.20 |
6.8mm |
2x0.50mm² |
2x16/0.20 |
4.5mm |
4x0.50mm² |
4x16/0.20 |
5.2mm |
6x0.50mm² |
6x16/0.20 |
6.0mm |
8x0.50mm² |
8x16/0.20 |
6.8mm |
10x0.50mm² |
10x16/0.20 |
7.6mm |
12x0.50mm² |
12x16/0.20 |
8.0mm |
Fire Cable/Fire Alarm Cable
Â
Cable Size |
Specification |
Overall Diameter |
2x0.5mm² |
2x0.8mm |
4.80mm |
2x2x0.5mm² |
4x0.8mm |
6.00mm |
2x1.0mm² |
2x1.15mm |
5.30mm |
2x2x1.0mm² |
4x1.15mm |
6.60mm |
2x1.5mm² |
2x1.40mm |
5.90mm |
2x2x1.5mm² |
4x1.40mm |
7.20mm |
2x2.5mm² |
2x1.80mm |
6.80mm |
2x2x2.5mm² |
4x1.80mm |
8.00mm |
Application:
For internal wiring in class 2 circuits of electronic equipment or TV game data transmission.
Â
Packing:
1)Packing Lengths: 100m/roll, 200m/roll, 305m/roll, 100yard/roll, 200yard/roll, 300yard/roll.
2) Inner packing:Roll, Wooden reel, plastic reel, and paper reel.
3) Outer packing: Carton box, pull out box, pallet available.
4) Other packing available according to client's request.

Â
The FirstPower Standard series is desgined for apllcation of general portable purpose . The series is a modern hi-tech energy application product, and the first generation delicate product in our company.
We welcome orders with "FirstPower" brand; We are also flexible to accept orders on OEM basis. Contact us now! Your partnership with FirstPower will prove worthy of it.
Standard Series Battery,Standard Motorcycle Battery,Standard Car Battery,Standard 12V Battery
Firstpower Tech. Co., Ltd. , http://www.firstpowersales.com