Model NO.: BR-H15 solar powered street lamps
Input Voltage: 12V/24V
With Light Source: With Light Source
LED Chips Brand: Bridgelux
LED Lamp: 9W to 120W
Solar Street Light Pole: 3m-12m Hot Galvanized Pole
Solar Battery: 100ah-250ah Gel Battery
Solar Controller: 15A/20A 12V/24V PWM
Battery Place: Hang on The Pole
Warranty: 3 Years,5 Years
Average Life: >8000h,8000h
OEM ODM: Yes
IP Level: IP67
Pole Height: 3m to 12m Street Light Pole
Trademark: Bright, BR Solar, AS Solar
Transport Package: Carton & Pallet
Specification: 9W to 120W solar powered street lamps
Origin: China
HS Code: 85414020
Model NO.: BR-H15 solar powered street lamps
Input Voltage: 12V/24V
With Light Source: With Light Source
LED Chips Brand: Bridgelux
LED Lamp: 9W to 120W
Solar Street Light Pole: 3m-12m Hot Galvanized Pole
Solar Battery: 100ah-250ah Gel Battery
Solar Controller: 15A/20A 12V/24V PWM
Battery Place: Hang on The Pole
Warranty: 3 Years,5 Years
Average Life: >8000h,8000h
OEM ODM: Yes
IP Level: IP67
Pole Height: 3m to 12m Street Light Pole
Trademark: Bright, BR Solar, AS Solar
Transport Package: Carton & Pallet
Specification: 9W to 120W solar powered street lamps
Origin: China
HS Code: 85414020
Africa solar energy saving solar powered street lamps
Product Specification
4.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height | 6M | 6M | 8M | 8M |
LED Lamps | 20W | 30W | 45W | 60W |
Solar Panel | 110W*1PC | 80W*2PC | 120W*2PC | 150W*2PC |
Solar Battery | 100Ah/12V*1PC | 150Ah/12V*1PC | 120Ah/12V*2PC | 150Ah/12V*2PC |
Battery Box(Optional) | Engineering Steel | Engineering Steel | Engineering Steel | Engineering Steel |
Battery Box(Optional) | Engineering Plastic | Engineering Plastic | Engineering Plastic | Engineering Plastic |
Solar Controller | 10A/12V | 15A/12V | 10A/24V | 15A/24V |
Packing:40'HQ | 150 Units | 130 Units | 100 Units | 90 Units |
5.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height | 6M | 6M | 8M | 8M |
LED Lamps | 20W | 30W | 45W | 60W |
Solar Panel | 90W*1PC | 65W*2PC | 90W*2PC | 120W*2PC |
Solar Battery | 100Ah/12V*1PC | 150Ah/12V*1PC | 120Ah/12V*2PC | 150Ah/12V*2PC |
Battery Box(Optional) | Engineering Steel | Engineering Steel | Engineering Steel | Engineering Steel |
Battery Box(Optional) | Engineering Plastic | Engineering Plastic | Engineering Plastic | Engineering Plastic |
Solar Controller | 10A/12V | 15A/12V | 10A/24V | 10A/24V |
Packing:40'HQ | 150 Units | 130 Units | 100 Units | 90 Units |
Main Components Of Solar Powered Street Lamps
![]() |
LED Street Lamp Producing Power 9W-250W High Lumen:150-150LM/W;Lifespan:50000-100000Hrs |
* Technical Descriptions | |
* Lamp Body: High-Pressure Die-Casting Aluminum. Corrosion Resistant,IP65 or IP68 | |
* Application with Polyester Substance in its Surface. | |
* Reflector: High Purity Aluminum or Stainless Steel SS304,Mirror Polish. | |
* LED Cooler: Aluminum Material, Producing By Module | |
* Cover Glass: High Strength and High Transparent Toughened Glass | |
* Fastener Bolt and Screws: Stainless Steel, Anti-theft screw. | |
* Ambient Temp:-40~+50°C;Humidity:10%~95% | |
* Arm Diameter: 48 or 60mm | |
Solar Panel 18V/36V--Poly &Mono Silicon 5W-310W | |
* Before Production
-Control Of  Raw Material Before Use-Data Recording Of  Raw Material---Products Tracebility | |
* During production
-Control At Each Step Of  Production-Validation Of Each Step By Quality Controllers | |
* After production
-Systematic Flash Test On Each PV Modules-Quality Control With IEC Compliance -Tests In Our Facility Testing -Optional: Third Party Inspection Before Shipment If Needing. | |
* Limited Warranty -Workmanship for 5 years,90% of minimum power output over 12 years,80% over 20 years. -The Solar Panels Are Manufactured In According To The IEC61215 Standards.Lifespan:20-25 Years | |
Solar Battery 24AH~250AH/12V | |
* Gelled battery, Sealed Type. Deep Cycle. Maintenance Free. | |
* Real Green Power | |
* Low Internal Resistance | |
* Low Self-discharging Rate | |
* Long-life Design | |
* Wider Temperature Range | |
* Extremely good discharge recovery ability | |
 Solar Charge Controller,IP68 Rating | |
* Intellectual Control Technology Based On MCU And Special Software. | |
* Adopt Tandem PWM Charge Control Method, So That The Voltage Loss Of Electrical Circuit Is Only The Half Of  Diode Charge, Charge Efficiency To Improve By 3% - 6%. | |
* The Over Discharging Recovery Control And Automatically Floating Charge Control Can Prolong The Battery Service Life. | |
* Battery Reverse Connection Protection, Over-voltage Protection And Under-voltage Protection. | |
* Solar Module Reverse Connection Protection. | |
* Automatically Recovery Output, Output Over Current Protection And Out Short Circuit Protection | |
* Intelligent Time Control System, It Can Set Up 1-15 Hours Timing Or Delay Time ( Set Period To Resume Current Output, Two Period Can Be Set.) | |
* Light Control, Time Control, Temperature Control | |
* High-precision Voltage Control For The Battery Safety Work. | |
* Waterproof Design. | |
Steel Pole From 3M-12M For Street Lighting. 15M-50M For High Mast Pole | |
* Material -Q345B/A572,Minimum Yield Strength>=345n/mm2 -Q235B/A36,Minimum Yield Strength>=235n/mm2 | |
* Shape -Round, Multi-pyramidal, Column form, Polygonal Or Conical | |
* Production Process Raw Material Test→Cutting→Molding Or Bending →Welding (Longitudinal ) →Dimension Verify→Flange Welding→Hole Drilling →Calibration →Debur →Galvanization Or Powder Coating, Painting→Recalibration→Thread→Packaging |
Advantage Of Solar Street Lighting Syatem
* Green Energy,Low Power Consumptiom,Save 60%~80% Than Others.
* Higher Power,Higher Brightness Intensity,Good Color Rendition.
* Save Electricity Cost,Save Electric Transformer And Cable Cost,Free Maintanenance.
* Environmental Impact---Eliminate Hazardous Disposal,Low Light Pollution,No Radiation.
* Longer Lifetime: Between 80000-100000 Hrs,If Lighting 12Hrs/Night Could Use At Least 12-22 Years.
* Less Heat Generated Compared To Other Sourses.
* Downward Orientation Of Light Could Adjust Lighting Angles And Lighting Range And Shape On The Ground To    Meet The Road-rectangular,Other Lighting Source Just Could Give Common Round Shape And Small Lighting     Range.
Different Solar Street Light Battery Box Design For Choosing


Â
Â

Product Specification
4.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height | 6M | 6M | 8M | 8M |
LED Lamps | 20W | 30W | 45W | 60W |
Solar Panel | 110W*1PC | 80W*2PC | 120W*2PC | 150W*2PC |
Solar Battery | 100Ah/12V*1PC | 150Ah/12V*1PC | 120Ah/12V*2PC | 150Ah/12V*2PC |
Battery Box(Optional) | Engineering Steel | Engineering Steel | Engineering Steel | Engineering Steel |
Battery Box(Optional) | Engineering Plastic | Engineering Plastic | Engineering Plastic | Engineering Plastic |
Solar Controller | 10A/12V | 15A/12V | 10A/24V | 15A/24V |
Packing:40'HQ | 150 Units | 130 Units | 100 Units | 90 Units |
5.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height | 6M | 6M | 8M | 8M |
LED Lamps | 20W | 30W | 45W | 60W |
Solar Panel | 90W*1PC | 65W*2PC | 90W*2PC | 120W*2PC |
Solar Battery | 100Ah/12V*1PC | 150Ah/12V*1PC | 120Ah/12V*2PC | 150Ah/12V*2PC |
Battery Box(Optional) | Engineering Steel | Engineering Steel | Engineering Steel | Engineering Steel |
Battery Box(Optional) | Engineering Plastic | Engineering Plastic | Engineering Plastic | Engineering Plastic |
Solar Controller | 10A/12V | 15A/12V | 10A/24V | 10A/24V |
Packing:40'HQ | 150 Units | 130 Units | 100 Units | 90 Units |
Main Components Of Solar Powered Street Lamps
![]() |
LED Street Lamp Producing Power 9W-250W High Lumen:150-150LM/W;Lifespan:50000-100000Hrs |
* Technical Descriptions | |
* Lamp Body: High-Pressure Die-Casting Aluminum. Corrosion Resistant,IP65 or IP68 | |
* Application with Polyester Substance in its Surface. | |
* Reflector: High Purity Aluminum or Stainless Steel SS304,Mirror Polish. | |
* LED Cooler: Aluminum Material, Producing By Module | |
* Cover Glass: High Strength and High Transparent Toughened Glass | |
* Fastener Bolt and Screws: Stainless Steel, Anti-theft screw. | |
* Ambient Temp:-40~+50°C;Humidity:10%~95% | |
* Arm Diameter: 48 or 60mm | |
Solar Panel 18V/36V--Poly &Mono Silicon 5W-310W | |
* Before Production
-Control Of  Raw Material Before Use-Data Recording Of  Raw Material---Products Tracebility | |
* During production
-Control At Each Step Of  Production-Validation Of Each Step By Quality Controllers | |
* After production
-Systematic Flash Test On Each PV Modules-Quality Control With IEC Compliance -Tests In Our Facility Testing -Optional: Third Party Inspection Before Shipment If Needing. | |
* Limited Warranty -Workmanship for 5 years,90% of minimum power output over 12 years,80% over 20 years. -The Solar Panels Are Manufactured In According To The IEC61215 Standards.Lifespan:20-25 Years | |
Solar Battery 24AH~250AH/12V | |
* Gelled battery, Sealed Type. Deep Cycle. Maintenance Free. | |
* Real Green Power | |
* Low Internal Resistance | |
* Low Self-discharging Rate | |
* Long-life Design | |
* Wider Temperature Range | |
* Extremely good discharge recovery ability | |
 Solar Charge Controller,IP68 Rating | |
* Intellectual Control Technology Based On MCU And Special Software. | |
* Adopt Tandem PWM Charge Control Method, So That The Voltage Loss Of Electrical Circuit Is Only The Half Of  Diode Charge, Charge Efficiency To Improve By 3% - 6%. | |
* The Over Discharging Recovery Control And Automatically Floating Charge Control Can Prolong The Battery Service Life. | |
* Battery Reverse Connection Protection, Over-voltage Protection And Under-voltage Protection. | |
* Solar Module Reverse Connection Protection. | |
* Automatically Recovery Output, Output Over Current Protection And Out Short Circuit Protection | |
* Intelligent Time Control System, It Can Set Up 1-15 Hours Timing Or Delay Time ( Set Period To Resume Current Output, Two Period Can Be Set.) | |
* Light Control, Time Control, Temperature Control | |
* High-precision Voltage Control For The Battery Safety Work. | |
* Waterproof Design. | |
Steel Pole From 3M-12M For Street Lighting. 15M-50M For High Mast Pole | |
* Material -Q345B/A572,Minimum Yield Strength>=345n/mm2 -Q235B/A36,Minimum Yield Strength>=235n/mm2 | |
* Shape -Round, Multi-pyramidal, Column form, Polygonal Or Conical | |
* Production Process Raw Material Test→Cutting→Molding Or Bending →Welding (Longitudinal ) →Dimension Verify→Flange Welding→Hole Drilling →Calibration →Debur →Galvanization Or Powder Coating, Painting→Recalibration→Thread→Packaging |
Advantage Of Solar Street Lighting Syatem
* Green Energy,Low Power Consumptiom,Save 60%~80% Than Others.
* Higher Power,Higher Brightness Intensity,Good Color Rendition.
* Save Electricity Cost,Save Electric Transformer And Cable Cost,Free Maintanenance.
* Environmental Impact---Eliminate Hazardous Disposal,Low Light Pollution,No Radiation.
* Longer Lifetime: Between 80000-100000 Hrs,If Lighting 12Hrs/Night Could Use At Least 12-22 Years.
* Less Heat Generated Compared To Other Sourses.
* Downward Orientation Of Light Could Adjust Lighting Angles And Lighting Range And Shape On The Ground To    Meet The Road-rectangular,Other Lighting Source Just Could Give Common Round Shape And Small Lighting     Range.
Different Solar Street Light Battery Box Design For Choosing


Â
Â
DG200 Double Roller Granulator
DG200 Double Roller Granulator,Fertilizer Granulator Machine,Fertilizer Making Machine
Dry Roll Press Granulator Co., Ltd. , http://www.nspelletmill.com