Symptom: The user sent a 25-inch CRT TV set. When working, if the remote control is turned off, there will be bright spots on the screen, which will not disappear for a long time. If you turn off the power switch on the TV directly, the screen will be turned off. There are no bright spots on the top.
Repair process: The power supply of the machine is from the switching power supply. After the remote control is turned off, the power supply voltage of the test is still 180V. Therefore, after the remote control is turned off, there are always 180V voltage on the three cathodes of the picture tube. In this way, some of the picture tubes will have parasitic rays, so that bright spots will appear on the screen during standby.
Treatment method: 1. Disconnect the copper and platinum that leads to the view board after the filter capacitor of the view power supply. 2. Wire the two pins of the normally open switch of a relay (12V.10A) to the ends of the disconnected copper and platinum. 3. The two pins of the relay coil are wired to the controlled 12V power supply to ground. 4. Fix the relay with hot melt adhesive on the board where it is free.
After this processing, when the TV is working, the controlled 12V supplies power to the relay, its normally open switch is turned on, the view power supply can reach the video playback board, and the TV is not affected by the modified circuit; when the TV is in standby, Due to the disappearance of the controlled 12V voltage, the relay loses its power supply, and its normally open switch is in the off state. The power board loses 180V power supply, and the three cathode voltages are also 0V, so the picture tube will not Parasitic rays will be produced.
After the test machine is turned off by remote control, no bright spots appear on the screen and the repair is successful. QQ picture 20160114200712.jpg

1.27mm Female Pin Header

1.27mm (0.050") Pitch Female Headers
Like the 1.27mm pitch male header, the 1.27mm pitch female header is used in densely-packed devices, requiring space-saving connections. The low profile, 1.27mm pitch female header addresses the need for connecting a variety of board-to-board configurations, with vacuum pick and place that makes it suitable for high volume automated manufacturing. It can be available in varying elevated stack heights, pass-through, rugged, high-density, and in numerous low-cost designs.
Antenk offers 1.27mm pitch female headers in either SMT or THM orientation at high quality and affordable China-quoted price that snuggly fits with the pins of a male header and acts as a receptacle.
Assembly and service is simple with either vertical (straight), elevated or at a right angle orientation, which can dissipate current of about 1.0 A or less in a tape and reel packaging. The filleted corners can also remove shadowing allowing optimization of LED output.
The 1.27mm pitch female headers are commonly found in PC`s and are also made to work in Arduino boards, Arduino Pro and Arduino Mega with either single or double-row female headers, facilitating connections for programming and incorporation into other circuits. They have the perfect height for clearing the USB-B connector and great for stacking multiple shields.
Female header always called as [Header connector", Antenk provide widely range of header connector, from 2.54mm (.100″ inch) pitch to 1.0mm (.039″ inch) pitch. The number of pins (contacts) is from 2 to 40 pins per orw. There are three type: Straight (Dip Vertical), Right angle, SMT (surface mount).
If you can not find the items you interest from above items, welcome to contact us, and you will always get fully responsive from us.


Applications of 1.27mm Pitch Female Headers
Its small size is most suitable for PCB connections of small equipment and devices such as:
Arduino Boards
Architectural and sign lighting
Retail and display lighting
Fluorescent LED retrofit lighting
Cabinet or furniture lighting
Commercial / residential cove lighting
WiFi equipment
Gaming consoles,
Measurement instruments
Medical Diagnostic and Monitoring equipment
Communications: Telecoms and Datacoms

Industrial and Automotive Control and Test


Mount Type: Through-hole vs Surface Mount
At one side of this female header is a series of pins which can either be mounted and soldered directly onto the surface of the PCB (SMT) or placed into drilled holes on the PCB (THM).

Through-Hole (Poke-In)
Best used for high-reliability products that require stronger connections between layers.
Aerospace and military products are most likely to require this type of mounting as these products experience extreme accelerations, collisions, or high temperatures.
Useful in test and prototyping applications that sometimes require manual adjustments and replacements.
1.27mm vertical single row female header, 1.27mm vertical dual row female header, 1.27mm Elevated single row female header, 1.27mm Elevated dual row female Header, 1.27mm right-angle single row female header and 1.27mm right-angle dual row female header are some examples of Antenk products with through-hole mount type.

Surface-Mount
The most common electronic hardware requirements are SMT.
Essential in PCB design and manufacturing, having improved the quality and performance of PCBs overall.
Cost of processing and handling is reduced.
SMT components can be mounted on both side of the board.
Ability to fit a high number of small components on a PCB has allowed for much denser, higher performing, and smaller PCBs.

1.27mm Right-angle Dual Row female header, 1.27mm SMT Single row female header, 1.27mm SMT Dual row female header and 1.27mm Elevated Dual Row female Header are Antenk`s SMT female headers.


Soldering Temperature for 1.27mm Pitch Female Headers
Soldering SMT female connectors can be done at a maximum peak temperature of 260°C for maximum 60 seconds.

Pin-Type: Vertical (Straight) and Right-Angle
1.27mm pitch female headers may be further classified into pin orientation as well, such as vertical or straight female header or right-angle male header.

Vertical or Straight Female Header Orientation
One side of the series of pins is connected to PCB board in which the pins can be at a right-angle to the PCB surface (usually called "straight" or [vertical") or.

Right-Angle Pin Female Header Orientation
Parallel to the board's surface (referred to as "right-angle" pins).
Each of these pin-types have different applications that fit with their specific configuration.


PCB Connector Stacking
Profile Above PCB
This type of configuration is the most common way of connecting board-to-board by a connector. First, the stacking height is calculated from one board to another and measured from the printed circuit board face to its highest insulator point above the PCB.

Elevated Sockets/Female Headers
Elevated Sockets aka Stacked sockets/receptacles or Mezzanine are simply stacked female headers providing an exact distance requirement between PCBs that optimizes electrical reliability and performance between PCB boards.

Choosing this type of stacking configuration promotes the following benefits:
Connector Isolation - the contacts are shrouded preventing cable connection mishaps and good guidance for the mating header connectors.
For off-the-shelf wireless PCB module, stacking height is optimized with elevated sockets.
Offers superior strength and rigidity.
Polarisation prevents users from inverted insertion.

Single, Dual or Multiple Number of Rows
For a 1.27mm straight or vertical female header, the standard number of rows that Antenk offers ranges from 1 to 2 rows. However, customization can be available if 3 ,4 or n number of rows is needed by the customer. Also, the number of contacts for the single row is about 2-40 pins while for dual row, the number contacts may vary from 2-80 pins.

Pin Material
The pins of the connector attached to the board have been designed with copper alloy. With customer`s demand the pins can be made gold plated.

Custom 1.27mm Pitch Female Headers
Customizable 1.27 mm pitch female headers are also available, making your manufacturing process way faster as the pins are already inserted in the headers, insulator height is made at the right size and the accurate pin length you require is followed.
Parts are made using semi-automated manufacturing processes that ensure both precision and delicacy in handling the headers before packaging on tape and reel.

Tape and Reel Packaging for SMT Components
Antenk's SMT headers are offered with customizable mating pin lengths, in which each series has multiple number of of circuits, summing up to a thousand individual part number combinations per connector series.

The tape and reel carrier strip ensures that the headers are packaged within accurately sized cavities for its height, width and depth, securing the headers from the environment and maintaining consistent position during transportation.

Antenk also offer a range of custom Tape and reel carrier strip packaging cavities.

Pcb Connector,1.27Mm Female Pin Header,1.27 Header connecto,1.27Mm Pcb Header,1.27Mm Pcb Connector,0.050" Female Headers,1.27mm Female Pin Header SMT, 1.27mm Female Pin Header THT

ShenZhen Antenk Electronics Co,Ltd , https://www.antenkwire.com

Posted on