BenQ BenQ W1070+ experience (3D, side projection function explanation)

Reasons for purchase> Appearance> Experience> 3D> Side Projection> Sound Quality> Heat> Noise> Lamp Life> Miscellaneous> Reasons to Buy

The room needs a device to watch TV and watch movies. The computer monitor is too small, sitting in a chair and watching videos, and lying in bed watching videos are two experiences after all.

Originally wanted to buy a 55-inch TV. But last year, he did not use his hands. This year he had an interest and discovered that prices had exploded.

Aunt Zhang has been saying that Sony is more than embarrassed and irritated. What made the old man give you a shot and see if it is true or false?

No matter what, my psychological prepayment for the 55-inch is 4000-5000. (Suning 55X7000D had been to 4200 or 4600 in the previous period, but Hangzhou was out of stock! It is now off the shelf)

Home-made Hisense or anything is also seen by the critics. After all, TV industry really does not understand.

In fact, Xiaomi TV has also considered. but. . No stock. 3699 when the entire network out of stock. Then he said that the price increase was 300. The next day, everything was in stock. admire. It was lost in the next. Then split the design of the 55-inch still off the shelf. (Making way for Xiaomi TV 4? Posted on March 21)

Let's see it, forget it. Not much to say. The wall was pushed down by the crowd and broke the crowd. (But if you think about it back, if LeTV really fails, what impact does it have on us? What good is it?)

Hesitant for a long time, just w1070 + price cuts 200. Looked down, historical prices, it seems that has been around 4688, stunned for 3 years, firm not.

(Projector this industry does not understand. But the simple thing is, as if all people are unanimously approved, home 1080P, W1070 + is a god machine. Sometimes it is like this, less choice, life is simple)

Finally, at the end of the event, the order was placed. (Side comfort yourself: If the effect is not enough, it will be no big deal for the 7 days.)

(Actually, I'm a bit worried about the 1070+ being out for 3 years. It will be delisted one day. The W1110 is expensive, but it also castrates the side cast. For our renting party, the side cast is a good thing.)

BenQ W1070+ Home Full HD projector (DLP chip 2200 lumens 1080P Blu-ray 3D mobile phone with screen) 4688 yuan more bright and convenient, home projection good choice Jingdong direct link to Wikipedia


Appearance Gallery

The projector was sent directly from the BenQ box. One pair of 3D glasses, one hdmi is placed in the bag (the remaining two glasses should be praised and sent to BenQ, then post reissue, there are 50 Jingdong card)

The disassembled drawing will not be made anymore. Projector + remote + power cord + 2 batteries + manual + warranty card

On the left is the heat vent, the hot wind. The lens on the right has a lid. Manually

The back of the buttocks. Hdmi seems to be 1.4 (the second hdmi supports mhl, the first one does not support). There are other Barabara interfaces.

Anyway, I use a hdmi, a power supply. It is estimated that sound output will also be used.

experience feelings

The first boot, the boot page is very easy to understand. In the case of a positive shot, the picture is well adjusted, and it is almost a matter of two strokes. Unimagined hard

(The W1070+ has two simple and advanced menus)

Directly on the map


This is a small office of the company. There is no light above. You can notice that light comes in in the upper right corner, so the projected page has a gradual change from light to dark. The following is the effect of turning on the lights. Note that there is a LED light board above the picture. The picture of reality is better than the picture. Colourful, the trajectory of basketball can also be seen very clearly (I heard that some slag dregs TV, watching football or something, the ball will disappear?)

A demanding shot in Your Passing the World. In the office, where there is no light (it is the first basketball video environment above), this scene is ambiguous and almost nothing is visible. Now this picture is my screenshot of Youku, not taken. (Personally thinks that it may be because black is not good at all, there is light, and black is more grayish. Then it blends in with the gray picture inside, and then it gets stuck.)

This is what it looks like when it is dark at 10pm. The character's face and clothes are normally displayed. (6s shot, lens zoomed in, desktop computer monitor in the lower left corner)


3D

Here is a pit! ! It is a pit! It is a pit! Completely uncertain! Later, finally Baidu, found a solution.

The landlord downloaded the "left and right 3D" source (open video, in fact, two pictures are playing) (it is not clear how to achieve other sources)

Then the notebook (the landlord's 14-inch 1366*768 book) is connected to the projector, set "only projector display" (this time the notebook screen is no picture, the projector has a picture), and then play the video (can also be played at the beginning The video is played normally with an ordinary player. At this time, the video screen is still left and right.) Then the projector sets 3D mode and selects "Side by Side". Then 3D glasses, click on the boot, less than 5 seconds, you can see the 3d effect (you need to use the remote control to exit 3D mode). The effect is yes, but the landlord, the spectacles party, and the two glasses are also awkward and tired. (In fact, it can be predicted that 3D is rarely used. The first source is a problem, but also have to download dozens of G, a process down, too much trouble. I mostly used to look at movies, TV Youku. So, too There is no such thing as 3D. Unless one day, you can watch 3D movies online.)

Side cast

This is also a pit, a pit, a pit! I completely understand the meaning of the wrong side cast. Think of the projector as if it is on the side and then it is projected in front of the projector, you can set the screen to pan to your front. Wrong or wrong! The projector lens must be in front of you (the projector's orientation is oblique!)

Like this, cast diagonally.

The picture that is thrown at this time should be a red box. If you look at the above and the right side, you can see the traces. Then the next step is to use the settings of the side cast to shift the screen to green. (Feeling this time the picture will be reduced a little, and then it will be deformed! Distorted! For example: The upper part of your picture is leveled, but the following is broken. The lower part is flattened on the upper part, the left part is vertical to the right part, and the right part is vertical to the left part. You are not parallel, left or right, or up and down.” But the perverted one is that although you look at the screen of your computer desktop is embarrassing, but when you play the video in full screen, you don’t see anything.” To bring out the basic ideal effect, you need to adjust the screen up and down, and adjust the height and position of the projector. It takes patience and certain techniques. Patience is the most important!!!!)

Sound quality

The projector comes with a speaker. The sound quality is not so bad. Can you tolerate the sound of a notebook? Can you endure the sound of 100,200 speakers? If you can, in fact, this own speaker has gone. (As for 5.1, 7.1, and 2.1, I've seen a post before, watching videos on the Internet online is actually 2.0 channels. So, I really want to play 5.1, 7.1, and honestly download dozens of G files and then use what DTS. Didn't you understand this piece of information and wait for the Great God of Science?

fever

You put your hands on the vents, it's really hot (not hot), warming hands in the winter. Where is the bottle of milk in the winter? About 5 minutes after the shutdown, the fan will keep running until the machine cools down (a "click" sound indicates that the fan has stopped. This should be a real shutdown.). (I'm assuming that I can buy a notebook cooler under the projector to assist with heat dissipation? If it helps, can it reduce the noise of the original fan? Waiting for answers.)

noise

When the movie has sound, it can completely cover the fan noise. When the environment did not sound, the fan's noise slowly came out. But the feeling did not reach the point of affecting the mood. It was already small. A half-meter away from it was even weaker. At 10 o'clock in the evening, the children's cries on the streets, or the kicks of the slippers downstairs and downstairs, are more noticeable than the sound of a fan. (The sound of the fan is a very low-frequency sound. It should be the sound of "call ~~~")

Lamp life

You can enter the advanced menu (normal menu can not be set), and then the lamp power (or the projector power), and the default is the energy-saving mode, it is recommended to select the smart energy-saving mode, lower power than the energy-saving mode.

Mess

Practice abdominal exercises against the projector

This is the Youku screen: "full" effect. The effect of "100%" should be 16:9, that is, the picture should be flattened and left behind.

Home Furnishing carbon steel metal five-story racks (send 5 pads + hooks bearing 200kg mesh border upward anti-shedding layer adjustable carbon steel paint rust-proof anti-corrosion specifications 55*30*150cm) kitchen shelves microwave shelf bookshelf Electrical Shelf Arrangement Shelves Shelves Shelves Shelves Storage Shelves Bathroom Storage Shelves Shelf Shelves Shelves Shelves (Suppliers Direct) Classic Black 79 Yuan 79 Yuan Amazon China Direct Links

This shelf was bought before the 79 to put debris, now used to reluctantly put the projector. Although it is a bit thin, but it is easy to adjust up and down, but also in the corner will not often touch.

Above the shelves there are plastic washers from the store. I also removed the heat for heat dissipation. For the specific effect, look at the first picture of the "side shot" module. (Because the following is the projector's feet fall, so use a cardboard pad)

Before there were nails on the wall, black holes were left after unplugging, and a little white toothpaste was used to make up for it.

to sum up

First, 100% of the company killed the company's cheap commercial projection. Everyone really, don't expect the effects of w1070+ projections to be dominated by more than 2,000 garbage projections. I purposely called my colleagues to experience the effects together. 100% of colleagues said that this effect is very good.

In front of the 120-inch projector, the 55-inch TV is really a big deal. You can say that the TV is good and the display is fine, but such a big projector can make it easy for you to see the content.

(However, it seems that the lights are all off, the projection is on, and the eyes are a little bit painful. Do you want to open the low light on the bedside?)

Although I don't know, what is the effect of a projector that is 500 cheaper than the w1070+, how is the effect of a cheaper 1000, 2000, and a more expensive product will not work better.

But I think the effect of w1070+ is still very satisfactory

There is not a saying: If something doesn't understand, then follow everyone. Although not necessarily good, it is generally not too bad.

What is Rainbow Eye? Didn't feel any rainbow? (Everybody can't be science, ah, it's time to be popular science, and you can't forget it.)


Circuit Breaker

Miniature Circuit Breakers,Dc Circuit Breaker,12 Volt Circuit Breaker,Auto Circuit Breaker

Dongguan Andu Electronic Co., Ltd. , https://www.idofuse.com

Posted on