Cogès's new filter material for the PTFE fiber membrane layer

1. Unique ADMIREX filter construction

The surface spunlace cloth of ADMIREX filter material selected by Shanghai Kegesi Filtration Material Co., Ltd. is based on PTFE fiber, and has high heat resistance, chemical resistance, hydrolysis resistance and other properties. PTFE resin has a very high melt viscosity and it is difficult to make ultra-fine fibers. Daikin Industries Co., Ltd., a specialized manufacturer of fluororesins, has successfully developed a unique ultrafine-branched fiber with an average diameter of 10 μm using a special process (the fiber diameter is very fine, and the fiber is branched, like a tree right, see FIG. 2, so that fibers and fibers can be easily entangled together, the strength is relatively high, and the filtration accuracy will be higher), and then developed ADMIEX filter material, thereby achieving a high trapping performance of sub-micron particles, reducing the pressure loss.

2. Extremely high strength retention

The ADMIREX filter material selected by Shanghai Kegesi Filtration Material Co., Ltd. uses surface layer filtration as the filtration method. The collected particles will hardly accumulate on the support layer. Therefore, the strength (wear and tear) caused by the powder is minimal and can be maintained for a long time. Maintain a stable intensity inside. The filter material was tested under a load of 1.5 kg and sprayed 100,000 times, and the intensity reduction rate was 15%.

3. Chemical resistance

The PTFE fibers used in the ADMIREX filter media selected by Shanghai Kegesi Filtration Material Co., Ltd. show a stable state in addition to all chemicals other than fluorine gas (elemental fluorine), chlorine trifluoride, and molten alkali metal. Corrosion by all acids, bases, oxidants, organic solvents; Best heat resistance in organic fibers, up to 260°C for instant use (ADMIREX is composite material, chemical resistance and heat resistance after filter bags are made Sex depends on the characteristics of the support layer); it also has high hydrolysis resistance.

4. Low pressure loss and stability

Since 胛FE has non-sticky and surface filtration methods, the pressure loss of ADMIREX filter is small and stable, and the number of pulses (cleaning) is reduced, which reduces the degree of damage to the filter bag, increases the service life of the filter, and reduces the Maintenance operations.

5. Strong physical resistance

The thickness of the filter layer of ADMIREX filter used by Shanghai Kegesi Filtration Material Co., Ltd. is about 100 μm, and it has strong physical capability for pulse (cleaning), transportation, and installation.

6. Reaction function of ADMIREX filter particle adhesion layer

The thickness of PTFE fiber layer of ADMIREX filter material selected by Shanghai Kegesi Filtration Material Co., Ltd. is about 10 times thicker than that of PTFE film. The surface layer is filtered well, and the particles will not enter into the interior but will form on the surface layer formed by the sticky structure. Particle adhesion layer. Garbage incinerator fumes need to be neutralized and absorbed. Poisonous gases (such as acidic substances and dioxins) are not absorbed in the absorption tower, and they can react on the particle adhering layer on the ADMIREX filter, and are then removed by adsorption, so that toxic and harmful gases can reach national standards when discharged.

7. Cost-effective

The ADMIREX filter material selected by Shanghai Kegesi Filtration Material Co., Ltd. adopts a unique composite process and PTFE characteristics, and the service life of the filter material is prolonged, which can prolong the cycle of bag replacement; the pressure loss and pressure change are stable, and the fan energy consumption is saved; Ash is cleaned, which reduces the injection pressure and the number of cleanings and reduces the energy consumption of the compressed air. Due to the strong dust retention ability, the amount of neutralizer and adsorbent is reduced.

Combo GPS Antenna

Currently, most GPS antennas are right-handed polarized ceramic media consisting of ceramic antennas, low-noise signal modules, cables, and connectors. Ceramic antenna, also known as passive antenna, dielectric antenna and patch, is the core technology of GPS Antenna. The reception ability of GPS antenna depends largely on its ceramic components. Low noise signal module, also known as LNA, is the part that amplifies and filters the signal. The selection of components is also very important, otherwise it will increase the reflection loss of GPS signal, resulting in excessive noise. Cable selection should also be based on reducing reflection to ensure impedance matching

Combo GPS Antenna,2 in1 GPS Antenna,3 In 1 GPS Antenna,GPS+WIFI Antenna,GPS +4G +Wifi antenna

Yetnorson Antenna Co., Ltd. , https://www.xhlantenna.com

Posted on