Samsung recently released the new Gear S3 smartwatch. As an upgraded version of the Gear S2, the new Gear S3 comes in two models, the FronTIer version and the Classic version. Both versions are larger than the previous generation Gear S2, not only the display is larger. The battery capacity is also higher, and the function is more abundant than the previous generations.
Below, we mainly introduce the Classic version. Compared with the FronTIer version, the Classic version is not much different. The difference is that the Classic version uses a stainless steel body, the appearance is relatively shiny silver, and the FrontTIer version adds LTE network function. It can realize high-speed 4G mobile network connection.
Although the two versions of the S3 belong to the same model, they all have their own characteristics. Samsung's smart watches have been upgraded to a new level, and these two versions may form a certain competition in the near future.
Design and screen
The first time I saw the Gear S3 Classic, the first impression was that it was a bit larger than the previous version of the S2. After careful study of the parameters, the new Gear S3 was 1.3 inches, while the previous generation Gear S2 was 1.2 inches. The screens of the two generations of smart watches use the same Super AMOLED technology. Even the resolutions of the two generations of watches are the same, both 360 & TImes; 360, but due to the different screen sizes, the number of pixels per inch (PPI) of the two watches is bound to be somewhat different, although the company has not yet announced the PPI of the smart watch. parameter. In any case, the look of this watch is very gorgeous, we tried to experience the next function, and found that it operates in a way that is somewhat different from other smart watches.
Samsung explained to us that the new watch has improved the magnetic accessories in the ring dial and feels better. Although the dial has increased in size, it is more comfortable to operate than the previous generation.
The new watch maintains the same design as the previous generation, but uses a silver outer frame instead of a black outer frame. There are two crowns on the side of the watch, but they are not rotatable, just two buttons that can be pressed.
So, how much is the new watch bigger than the previous generation S2? The Gear S3 Classic measures 46 x 49 x 12.9 mm, which means the new watch is 3 mm wider and 1 mm thicker than the previous generation. The weight has also increased from 42 grams in the previous generation to 57 grams. Seeing these comparisons, you can already feel the difference in the size of the two generations of watches.
After the release of the new watch, Samsung did not stop the shipment of the previous generation of S2 smart watches, but adopted a price reduction sale to clean up the inventory of S2, which did not give consumers more choices. If someone asks the editors which one they usually choose, the answer may be the previous generation because the previous generation was smaller and lighter.
However, the Gear S3 also has one of the most attractive features, the display is always on (AOD), and the display's always-on function is different from what you have seen before.
We learned that Samsung has been working on 768M of memory and is able to push information to the constantly bright screen. This requires that the constant display is not just colored. To be precise, it has 16 million colors to choose from. Can only be used for the current time. Seeing this feature, we also hope that Samsung's competitors will try to catch up, the sooner the better, because Samsung has solved the problem of automatic closing of smart watches.
Overall, the new watch is slightly more cumbersome in size and weight than the previous generation, and it's a bit rough on the wrist, but the increase in size also brings a bigger and better screen, and it's easier to operate. Rotate the dial and a larger battery.
More features require more battery power
Obviously, adding these fancy screen features will consume more power, and Samsung has clearly overcome this deficiency. Gear S3 has a built-in 380mAh battery, which can last up to 3-4 days in normal use. Compared with the official standby time of the previous generation watch for 2-3 days, it still has a lot of improvement.
What is the extra battery life in addition to making you feel more colorful? This time, in addition to the various sensors of the previous generation of products, Samsung Smart Watch has also added an altimeter and a speedometer to make the motion tracking function of the new watch more perfect. These sensors can help you record your personal habits and now you can record your sleep.
Most importantly, the Gear S3 can be used as a mobile phone speaker after pairing with a mobile phone, and can also receive calls through a smart watch. In addition, the Gear S3 can play streaming music over the wireless network (Frontier version can also be played over the LTE network), allowing the Spotify App to be installed on the Tizen 2.3.2 operating system used by the watch.
Finally, we also learned that Samsung is testing Gear S3's navigation and interactive functions for Gear VR glasses. They are trying to use the watch dial to operate the navigation menu of Gear VR glasses, and click on the watch screen to achieve the most basic operation. However, this feature is currently in the initial testing phase.
Other advantages
Gear S3 has a 1GHz dual-core processor built in, but Samsung has not announced the specific model of the processor, the memory is increased to 768M, the storage space is still 4GB, the watch screen is covered with Corning Gorilla Glass, and it also has Bluetooth 4.2, Wi -Wireless connection functions such as Fib/g/n, NFC and GPS.
In terms of sensors, in addition to accelerometers, gyroscopes, barometers, heart rate sensors and ambient light sensors, altimeters and speedometers have been added. Finally, the Gear S3 still achieves the IP68's dust and water resistance and can be used at extreme temperatures. It is compatible with smartphones with Android 4.4 or higher operating system, preferably with more than 1.5GB of memory.
Like the previous generation, the Gear S3 can use any 22mm wide wristband. Currently, some wristbands designed by designer Arik Levy are ready to go on the market, but as of press time, Samsung has not disclosed the price and details of the product. .
Early judgment
The Gear S3 Classic is a major evolution of Samsung's flagship smartwatch, adding size, battery capacity and functionality. But as the size increases, it also reduces its appeal as a fashion product. Traditional experience tells us that the smaller the number, the more popular it is.
Closer to home, the Gear S3 Classic has transcended the boundaries between functionality and appearance. Despite the sleek design and increased functionality, the success of this watch depends on the consumer's personal preferences.
One thing is for sure, Samsung has finally found the core concept of smart watch upgrade, maybe you will see a more perfect product in September next year.
However, for now, the Gear S3 Classic is one of the most beautiful and powerful smart watches in the world. We can't wait to put it on the hand for detailed evaluation.
Advantages: Dynamically bright display; more features; larger screen; larger battery capacity
Disadvantages: A bit cumbersome for some users.
Features: 12v Dc geared motor drive precision, small volume, large torque, low noise, durability, low energy consumption, customized power design,easy installation, easy maintenance;Simplify design and save space.
12V Dc Gear Motor, namely gear reduction motor, is based on ordinary Dc Motor, coupled with gear reduction gearbox.
The gear reducer is used to provide low speed and large torque.
At the same time, the gearbox with different deceleration ratio can provide different speed and torque.
Generally different industries, using different power dc motor, generally adopt custom parameter design pattern.
Method of use: the best stable in horizontal plane, installed on the 12v dc gear motor output shaft parts, cannot use a hammer to knock,knock prone to press into the 12v dc gear motor drive, may cause damage to internal components, and cannot be used in the case of blocked.
Operating temperature range:
12v Dc geared motors should be used at a temperature of -10~60℃.
The figures stated in the catalog specifications are based on use at ordinary room temperature catalog specifications re based on use at ordinary room temperature (approximately20~25℃.
If a geared motor is used outside the prescribed temperature range,the grease on the gearhead area will become unable to function normally and the motor will become unable to start.Depending on the temperature conditions ,it may be possible to deal with them by changing the grease of the motor's parts.Please feel free to consult with us about this.
Storage temperature range:
12v Dc geared motors should be stored ta a temperature of -15~65℃.
In case of storage outside this range,the grease on the gearhead area will become unable to function normally and the motor will become unable to start.
Service life:
The longevity of 12v Dc geared motor is greatly affected by the load conditions , the mode of operation,the environment of use ,etc.Therefore,it is necessary to check the conditions under which the product will actually be used .The following conditions will have a negative effect on longevity.Please consult with us should any of them apply.â—Use with a load that exceeds the rated torque
â—Frequent starting
â—Momentary reversals of turning direction
â—Impact loads
â—Long-term continuous operation
â—Forced turning using the output shaft
â—Use in which the permitted overhang load or the permitted thrust load is exceeded
â—A pulse drive ,e.g.,a short break,counter electromotive force,PWM control
â—Use of a voltage that is nonstandard as regards the rated voltage
â—Use outside the prescribed temperature or relative-humidity range,or in a special environment.
â—Please consult with us about these or any other conditions of use that may apply,so that we can be sure that you select the most appropriate model.


when it come to volume production,we're a major player as well .each month,we rurn out 600000 units,all of which are compliant with the rohs directive.Have any questions or special needed, please contact us, we have the engineer group and best sales department to service to you Looking forward to your inquiry. Welcome to our factory.
12V Dc Gear Motor,Dc Gear Motor 12V,12V Gear Motor,12V Dc Gear Motor 30 RPM
Shenzhen Shunchang Motor Co., LTD. , https://www.scgearmotor.com