There is a slight flaw in the white jade, which means that there is a little flaw on the white jade. This word is also my simplest and most straightforward experience with the Ticwatch 2 Generation Classic Sapphire smartwatch.
Foreword
Thanks again to Aunt Zhang’s favor, she got the Ticwatch 2nd Generation Smart Watch (later known as Ticwatch 2nd Generation). Ticwatch is a smart watch that I continue to focus on. The first generation had a simple experience, and it was indeed not very user-friendly for IOS users. Although there are also B-doors to follow, for users who are not willing to toss, the first generation is more for Android users. At that time, the rumor was that they had not obtained MFI certification and therefore could not be highly matched with the IOS system. Later, when the 2nd generation forging gold edition started crowdfunding, it also indicated that the 2nd generation products have been highly compatible with the IOS system, and I am more curious about this watch's love. I am more curious about how this watch works with the IOS. As a result, when he saw the aunts measuring the 2nd generation products, he did not hesitate to submit an application. At the end of June, I had a change in my work. The strength of my new employer was so high that there was almost no time to write the report, so I had not submitted it yet. Also hope that Aunt and many friends will forgive me!
Before long, SF Express delivered a package from Auntie. When I received the parcel, it was just before I lived, so the right was the birthday gift that Aunt gave me.
All in the parcel: A public test request description, ticwatch 2 generation, a charging base accessory and a screwdriver
-------------------------------------------------- ----------------------------------
The structure of this article is relatively simple, mainly from the following sections for everyone to show my use of this product experience.
Part.1 Product Background
Part.2 Unpacking
Part.3 Function/Use Simplified
Part.4 Advantages and Weaknesses
-------------------------------------------------- ----------------------------------
Part.1 Product Background
About ticwatch 2 generation smart watch, the first thing to know is that this product is from the domestic AI company go out and ask. Going out to ask has been optimized for the localization of Moto and LG's smart watch systems, so there is a lot of experience in the design of smart watch systems, whether UI or user experience. Therefore, in response to the trend of electronic products, they went out to ask questions and launched their first smart watch, the first generation of ticwatch in 2014. The table shape draws on the design of the MOTO 360 and is equipped with an Android-based ticwear OS after going out and asking for optimization. Although the first generation ticwatch draws more elements from the shape, but the system ground design of the excellent grounding gas and the entry price of less than one thousand yuan make this smart watch quickly establish a good user reputation in the market. When I was in Jingdong Shuang 11 with the coupons and gift cards to achieve the final price of less than 700 yuan, but in the end because the experience on the IOS system is almost 0 and ultimately no long-term use.
Obviously, going out to ask is very clear that the market share of IOS in the smart phone system is also leveraged. Compared with foreign companies' single-targeted research and development products, domestic companies prefer to engage in comprehensive compatibility strategies and wish that all markets are their own. Of course these are my own imaginary, but in any case, more powerful 2nd generation products turned out. For ticwatch 2 generation products, there are many versions, the first forged gold version, the later Yuet version and the classic version for everyone today.
The 2nd generation product is relative to the 1st generation product, has increased the support to the IOS system, has increased the independent communication function (the movement version does not have this function), increases the GPS module and so on. All of this seems to be more attractive than the first generation of products. Let's look at the selling price. The price rose to the 1499-1699 price range. In the domestic brand smart watches, the price is a high class. So what about this watch? Follow the rest of the text to find out.
-------------------------------------------------- ----------------------------------
Part.2 Unpacking
The ticwatch 2nd generation classic box uses the common top and bottom opening method of the watch box. There are simple LOGOs and words such as the gilt craft ticwatch, which is very simple. However, in fact, the packaging material is not high-end, and the actual perception is also the same. As the first thing that comes into view, the packaging can be a little more secure. After all, it is more than 1,600 things.
After opening it is such a fixed watch.
There are two boxes on both sides of the box on the top of the box, with instructions and charging accessories.
The surface of the charging head is a mirror finish process and looks very textured
Magnetic base is also very good workmanship, the bottom of a non-slip material, the actual feeling is very slippery. The ticwatch 2 generation uses the e-wireless fast charging scheme from IDT compared to the 1st generation. Officially stated that 100% of full power will be available within 2 hours. Measured in less than 2 hours will be full. If you simply use it as a watch, you will lose power within 24 hours. If you are connected to a cell phone or use it heavily, you will lose power in less than 10 hours.
The classic version I received was the version of the steel strap, because the strap used a butterfly buckle, so it could not be completely unwrapped like a regular strap to allow the watch to lay flat on the plane. Therefore, it is not known whether this is the reason. This time out of the watch itself, it also comes with a small accessory;
The official ticwatch calls it "energy volcano." In fact, the deity is a base with an infinite charger. The material is soft rubber material, and the process is general. There are reserved grooves at the bottom of the trace. However, it is not known whether the accessories are standard.
The charger module is placed above this
After unbuttoning the butterfly buckle, the watch can be directly placed on it, still quite worry-free
After briefly introducing the box and accessories, it is finally time to put a photo of the protagonist in this article. Honestly speaking, the craftsmanship of the watch outside the entire watch has been done very well. It seems that the above-mentioned informal places are designed to free up more energy to make every detail of the main watch.
The whole watch texture is great! This conclusion is no exaggeration, the actual effect of levering after wearing, do not lose a lot of traditional steel table 2K-3K price segment. During this period of time I was wearing, this watch was still quite eye-catching.
The one I got was a sapphire version, because there is no clear description of the configuration of the sapphire on the Internet, but there are users who propose that the classic version is not a sapphire screen. This is to be verified, and also hopes to understand the value of friends to explain. After the screen goes out, the surface is very beautiful
The strap is a butterfly buckle, I like this buckle, even if it does not let the watch fall to the ground
The strap uses a quick-release interface and is easy to disassemble.
However, it should be noted that the demolition of each strap is very painful - you need to unscrew the screws and then adjust the length of the strap. But what I said was not the pain of the process, but the screw was too tight. The supplied screwdriver has been slipped, but the screw is still motionless. Finally, I had to spend 20 bucks to find the master to get the table (the registrar was almost unscrewed, and the last vise waits to get it)
The ability to change the surface is also one of the more interesting selling points of smart watches like ticwatch. Change the dial at any time to suit different occasions. However, on the number of dials, IOS is obviously inferior to Android.
The dial screen can be set up to raise the screen and use the gravity sensor to raise the hand when the screen lights up. When the hand goes down, the screen is blank.
The ticwatch 2 Generation Classic Edition is equipped with a 400x400 pixel 287ppi 1.4 inch OLED LCD Screen , which has a certain increase in parameters compared to the 1st generation. The changes brought about are obvious - the appearance of the 2nd generation is clearer and more realistic. At the same time, the size of the dial has been reduced, so the whole watch is not as "hypertrophic" as it was in the first generation, and it becomes a little delicate.
Contrast with traditional watches. . Out of the biggest changes on the screen, in fact, the appearance is the traditional table (nonsense)
More than a few more
When the screen is charged, the screen is automatically horizontal, and the animation that starts charging instantly has a sense of technology.
Relatively speaking, I prefer the magnetic charging design like the pebble. However, both have their merits.
BTW, the strap of this pebble steel is not a regular shape, it is not as good as a ticwatch.
Heart rate detection element
-------------------------------------------------- ----------------------------------
Part.3 Function/Use Simplified
In this section, I will briefly explain some of the selling points of ticwatch 2 generation smart watches and some of the feelings of daily use.
The first is naturally a brief introduction of some of the features of the product itself. The first thing to get the hand is of course boot. The ticwatch's boot screen is still pretty good. But the boot time is really a little longer
After the boot is the registration page, the watch will guide you step by step how to match the phone, very convenient and intuitive. This kind of practice will allow users to get started faster than traditional manuals.
Download the Ticwear Client from the AppStore
Then when you log in for the first time, you will be asked to sign up for an account. .
Various information collection. . Of course, I don't normally fill in real information like this
Pairing mobile phones and watches can be automatically paired or manually paired by scanning the QR code
The mobile phone and the watch are seamlessly connected. When the mobile phone prompts the watch to change, the watch changes almost synchronously.
Preferences
There is a small problem here. Compared to traditional watches or other smart watches, the ticwatch adds a touch area for achieving "scratch" function, and according to the usage habits, the area is more smoothly to the outside, so the crown is recommended to be more scientific inside. This is also a small difference from traditional watches.
password setting. . After experiencing it, I found this feature annoying and I have turned off the password unlocking feature.
After this step, the pairing and binding of the IOS system is over, and the remaining data can be synchronized only with other data. So next I have to say that the matching degree between the IOS system and the ticwatch 2 generation is the problem of daily use. In fact, the second generation of the original claim is more compatible with the IOS system, but in terms of actual experience, compared to the first generation of products, the improvement in the degree of match for the IOS system is almost negligible. In other words, the overall feeling is how the first generation is, and the second generation is still. So this will make the Apple mobile phone users who buy this watch "highly compatible" IOS this selling point somewhat disappointed.
However, as a smart watch, perhaps my request is lower - that is, to be able to see the push, to remind the call is already available, and the rest to reply to the message, I think it is still Use your cell phone.
This piece of news push does a good job, almost all the news can be pushed.
If you use an iPhone, WeChat can only view messages (text messages, pictures cannot be viewed), and cannot reply to messages.
Ticwatch Remote Control Music This feature is useful to me. When you drive, you can cut the song without having to pick up the phone. The driving is relatively safer. There have been rumors that ticwatch's music control can only control songs within Apple's own music app. But in fact perfect control of QQ music
Today's headline is an application built into the watch, but the name is replaced with "news." It is still very convenient to view. I just think that if you see news that you are interested in under normal circumstances, you still have to check out the phone. After all, this 1.4-inch screen is too small for reading.
In addition, the push of the ticwatch can be set as a privacy push. After this function is enabled, if the watch screen is in a standby state, the push will not be displayed, and it needs to be activated after the screen is displayed. Turn off privacy push, then as long as there is a push, regardless of whether the watch is black, it will immediately light up the display. The starting point of privacy push is good, but there will be problems when the application is actually applied: When the screen is pushed out, you must light up the screen immediately. Otherwise, it may not be automatically displayed. You need to touch the screen to see the preview. It's inconvenient, so I've been turning this feature off. We hope that manufacturers can optimize this function of privacy push later.
The ticwatch 2 has Bluetooth connectivity options. At first I thought it was used to connect with a cell phone. The result later became clear that it was connected to a third-party device, such as a Bluetooth speaker.
However, songs played on the phone cannot be played back through the Bluetooth speaker after connecting. Drumming for a while to find the APP with its own sound effects in the watch, such as the voice in the weather can be played through the Bluetooth speaker.
The ticwatch 2 has a built-in GPS module, which means that you can use the watch's built-in navigation software separately from the phone. Navigation software uses Sogou's navigation and navigation interface.
The only problem with navigation is that the sound is too small. After all, the loudness of the watch is so great. Therefore, if you really want to use the watch navigation at this time, it is recommended to connect Bluetooth speakers out. . . From this point of view, the role of watches connecting to third-party devices via Bluetooth is still very useful at this time. . However, under normal circumstances, all use mobile navigation. . Watch navigation estimates are also emergency use in extreme situations.
The ticwatch 2nd generation classic version, compared to the 1st and 2nd generations of the active version, adds an offline call function. The classic version has a built-in SMD SIM card, and Minsheng Communications provides mobile network services.
It's just that I feel that this feature is really unnecessary. There are two reasons for this:
1, the general watch and the mobile phone are in the same time, the watch can directly call through the mobile phone
2, use the watch to call, brain fill it, do some people think this is very "cool"? ? ? . .
Anyway, in order to test the effect of the call, I talked to the watch as I walked. I also feel that the picture is too discordant. . .
But fortunately, the call effect was good, exceeding expectations. . But I still honestly call with my cell phone. This function is the same as navigation. It is also used in cases where it is not possible to use the mobile phone or use the mobile phone.
Put two real beasts at the end and see how it looks. During the period of experience, the weather in Chengdu was too hot. Everyday, sauna was not equipped with more formal clothing such as long-sleeved shirts. I remember that there were value-friends who had done a show with a dress, and interested friends could search in the station.
Because relative to the 1st generation, 2 represents a reduction in the size of the disk, so the overall slim a lot, wearing a good effect is basically a suitable size for men and women to wear
After roughly speaking about IOS, let's talk about matching with Android in this chapter. It can be said that after switching from Apple's mobile phone to Android mobile phone, the ticwatch completely "removed" (solution)! ! Yes, in the environment of Android phones, ticwatch has shown its strong side. In addition to the features mentioned above in the IOS section can be used in the Android phone environment, the Android phone can download applications, games, etc. after connecting the watch.
After the Android phone matches a good watch, there will be one more "sports" APP in the default application of the watch.
The rich dials and applications are the biggest advantage of the Android terminal.
More than the dial selection is more attractive to me. However, strangely, there are write-out dials that display errors, such as misaligned pointers, partial UIs, etc.
The dial under the Android phone matching is much more beautiful than the IOS own ~~~
Supporting the installation of third-party apps is also a big selling point after matching Android phones. . When you test, you must choose Zhang Aunt to test it~~~
You can do a simple check and it's better than nothing. Anyway, I'm not accustomed to watching this information on a watch.
Then there is the game APP. . All are simple games, some use touch screens, and some use gravity sensors. Gravity sensing applied to the watch I can not be a somatosensory game?
Put a game on the map. . Boring time is still quite interesting. .
The Android environment supports viewing of pushed image content, as well as support for replying. But need to open AW compatibility mode (IOS does not have this step)
The picture sent from the mobile phone can be directly viewed on the watch (IOS cannot)
Because there is no way to use Android phones for a long time, the Android section cannot give you more graphic descriptions. I hope everyone will forgive me.
-------------------------------------------------- ----------------------------------
Part.4 Advantages and Weaknesses
Before summing up the advantages and disadvantages, let us talk about the significance of ticwatch or smart watch. Before I used to write a pebble smart watch worth using to buy the original experience: http://post.smzdm.com/p/356144/
As the title of the article says, for a smart watch, first it must be a watch! Actually, my love for the first generation of pebbles has not yet receded. The reason is that there is no place for the watch to be placed at a lower level. This problem is exactly what is missing in all kinds of cool smart watches nowadays. Including ticwatch, the very short standby time leads to annoying one-day or even two-day-per-day charging. A super-plurality of applications and dials allow people to use the watch. More is to do things outside of time.
But for any problem, we must use a dialectical perspective to look at generations (to start self-face mode). Since the launch of the Apple Watch, smart watches have become popular. And smart watches give users more of a use experience that subverts traditional watches. With a smart watch, you can not only look at the time, but also make it easier to receive messages, view messages, and more. Rich applications can also meet many individual needs. So for this kind of smart watch, I would rather see it as a wearable smart device. This device has a function of watching time, but this device looks like a watch, so it is called a smart watch. If you look at the problem this way, it seems that the above problem has been solved.
Finally, summarizing the full text and seeing how the ticwatch 2-generation classic is
advantage:
The appearance of workmanship is first-class and the texture is very good. Under the premise of Android phone matching, many applications, dials, and games can be installed, further extending the functionality of the watch. It is also very good to support "offline" functions such as getting out of mobile navigation. Can replace the dial, to meet the needs of different occasions, the new low-light mode also bid farewell to the black screen can not be lit in time.
Disadvantages:
Advantages There is no need to praise too much, I believe more people are concerned about the lack of this watch. During the last two weeks of experience, as far as I am concerned, the main disadvantages are the following:
1, raising the screen can shorten the time, sometimes lifting the screen is still black, can not help but a little embarrassing. .
2, vibration can not be closed. This is annoying. The vibration is not very comfortable, and individuals do not like vibration. It is better to have a close option.
3, the screen does not automatically adjust the brightness, each manual adjustment, inconvenient. It is recommended that the product be added with automatic brightness function.
4, IOS experience is poor, can experience a more basic function, far better than Andrews, it is recommended to increase the IOS third-party application store.
5, "scratch" appears to be a humanized feature on the surface, but in fact, in accordance with the use of habits, users prefer to use the touch screen operation. The existence of scratching is more of a gimmick and not of much practical significance. However, this function cannot be turned off, so when the touch operation is performed, the touch area may be mistakenly touched to cause an erroneous operation. It is recommended that the off-hooking feature be added after the update.
Full text summary:
In the ticwatch 2 generation we can see that we want to make the ticwatch series stronger and stronger, and we can see some progress. Although there are still deficiencies in compatibility and matching with IOS, after all, the Apple system is relatively difficult to overcome. The ticwatch itself is also more focused on the development of Android-based phones, so the IOS system can have some common experiences on the 2nd generation and is not useless for IOS users. In a nutshell, if Android users are concerned, ticwatch 2 is a good choice or an option. For IOS users, it needs more consideration. Because of what ticwatch can do, other solutions are less costly.
TFT (Thin Film Transistor) is a thin film field effect transistor. The so-called thin film transistor means that each liquid crystal pixel on the Liquid Crystal Display is driven by a thin film transistor integrated behind it. This can Display Screen information at high speed, high brightness, and high contrast. TFT is an active matrix liquid crystal display.
The TFT-LCD liquid crystal display is a thin film transistor type liquid crystal display, also known as "true color" (TFT). TFT liquid crystal has a semiconductor switch for each pixel, and each pixel can be directly controlled by dot pulses, so each node is relatively independent and can be continuously controlled, which not only improves the response speed of the display, but also can be accurately controlled Display color gradation, so the color of TFT liquid crystal is more real.
In the fierce competition among many flat panel displays, why TFT-LCD can stand out and become the next-generation mainstream display is by no means accidental, it is the inevitable development of human technology and thinking mode. The liquid crystal has avoided the difficult light-emitting problem successively, and the light-emitting display device is decomposed into two parts by using the excellent characteristics of the liquid crystal as a light valve, namely the light source and the control of the light source. As a light source, brilliant results have been achieved in terms of luminous efficiency, full color, and life, and they are still being deepened. Since the invention of LCD, the backlight has been continuously improved, from monochrome to color, from thick to thin, from side fluorescent lamp type to flat fluorescent lamp type. The latest achievements in luminous light sources will provide new backlight sources for LCDs. With the advancement of light source technology, newer and better light sources will appear and be applied to LCDs. The rest is the control of the light source, the technology and process of the semiconductor large-scale integrated circuit are transplanted, the thin film transistor (TFT) production process has been successfully developed, the matrix addressing control of the liquid crystal light valve is realized, and the light of the liquid crystal display is solved. The cooperation of the valve and the controller enables the advantages of the liquid crystal display to be realized.
Tft Display,Tft Display Clear,Edp Tft Display,1.8 Inch Clear Tft Display
ESEN Optoelectronics Technology Co., Ltd, , https://www.esenlcd.com