Whenever there is a high temperature on the graphics card, the fan or even the water cooling is unbearable, I found a solution! Please take a closer look at the following
Ladies and gentlemen, there may be a lot of people who will find the graphics card in the desktop computer at home (in fact, it also includes the notebook's video card, but because the laptop is not easy to operate, this article does not mention it!) After a period of time (usually two or three years), the temperature Began to rise, moving more than 90 or even more than 100 degrees! The fan simply can't hold back. Even if you buy a fan with better quality, the same effect is not good! What's going on? Please be patient and look at my experience. You will know the ultimate solution!
A desktop computer at home, probably in 2012, has a 2500K CPU, and the 3.3G clock frequency is more than 4G. Graphics card is 560 TI, good graphics that year, not cheap! The pre-operation is basically normal! In fact, the overall use of time is small, and occasionally used.
However, some people love toss, such as me! In the 13 years I upgraded the motherboard BIOS. As a result, the motherboard was dead. Fortunately, during the warranty period, I replaced it with a motherboard. Then, another day, probably in mid-2013, I suddenly felt that it was cold! In fact, the entire system is completely normal and completely water-free! No matter, on! Spent 550 yuan, bought a set of domestic brand-name water-cooled backlog conversion goods! Set, even the complete set of CPUs and video cards are included! Water-cooled parts do not need to be assembled. Simply install the heat sink on the CPU and the graphics card. The approximate structure is as follows:
For an old man like me, installing it is simple. After installation, the CPU temperature down a few degrees, the graphics card temperature drop is not obvious, when the pager is still 80 degrees up and down, it is also good! Normal use! As a result, converting the assembled goods is not very good. A year later, I heard a loud call in the chassis, but for me, I can't tolerate it! So a check, it should be a water-cooled system lack of water! Ask the seller, the seller said that this water cooling, after a period of time is the lack of water! Grandma, don't say when you buy! ! ! Then, according to the water injection method provided by the seller, some water was injected. Do not ring.
Another year, the sound began to rise again, and once again added water. Every time water is added, the entire water cooling must be removed and it is more troublesome. When installing back, it often fails to open! No display! Sometimes plugging and unplugging the graphics card will be good, and later plugging and unplugging, the motherboard reset it. Anyway, it's back to normal use!
Found this year, the graphics card temperature is very high, it is 98 degrees! Then they were removed again and joined his son, adding a lot of water to it. Then, after installation, it will not work. The temperature will not come! What's going on? I pondered for a few days and thought that it should be a poor water cooling effect! Then add a heat sink to the CPU, so that water cooling alone for graphics cooling! For the two guys cooling into a heat, it should always be OK. Say dry! I bought a radiator that I think was good, eighty ninety, and put it on. Water cooling is only for graphics cards. As a result, the CPU temperature continues to maintain a relatively low temperature, the graphics card continues to heat, no change. Is it because I didn't install it? Remove it and coat it with new silicone grease. Reload it or not. The graphics card temperature is still high!
As a result, in the repeated tossing, the graphics card once again appeared in the previous phenomenon, no display. This sad reminder! No matter how you plug or unplug the motherboard, it will not work. Finished, in the end is the video card is broken? Or the motherboard can not! Headache for a few days, suddenly remembered, put an old card back to the unit many years ago to try! ! Verified, it should be the problem of the motherboard, the old graphics card plugged in, and no reflection. If you don't, buy it again and buy it on your second-hand motherboard. Carefully picked a motherboard of Asus Z77, think of it, not willing to buy, now 4 fold! Less than 400 yuan to hand, the fineness is not bad. Installed, the graphics card is bright! However, the graphics card temperature is still high!
If you don't achieve your goal, don't stop! It seems that one of the water-cooled systems is out of order and replaced entirely. Also on the treasure, re-enter a four heat pipe radiator, 10CM fan! Theoretically it is completely possible to suppress the video card temperature! As a result, unexpectedly, the temperature is higher! More than 100 degrees, reached 102, 103 degrees, often a machine, it crashed! I want to cry! Ask people who sell radiators, they can not say why this is so, just let it reinstall! I removed it and reloaded it, no difference! Temperature exceeds Baidu! ! !
Desperate! Desperate! Tossed two months, replaced all the heat sinks, the result is a higher temperature! I am sad and give up! At this time, when I was on the Internet, I suddenly saw an article mentioning that the silicone grease inside the chip would dry! With his grandmother, how can there be silicone grease inside the chip! If there is inside, it is really possible to dry out!
Remove the video chip cover! I do not know how to disassemble, online related materials are few, there is no careful description. There is a small part of the CPU's uncovering, but it seems to be different. Does not matter, the dead horse is a live horse medicine! Demolition yourself! Take the video card in his hand, use a paper knife, slowly cut along the circumference, sled, not to move, grandma's, under the brute force, the results of a hard, hey, the whole cover off! It turned out that the chip is not so delicate, as shown below (on the Internet to find, did not take pictures at that time), the chip lid is sticky around, with a bit of force to sled down, generally there will be no damage! In the middle is the real chip, on-chip grease (essentially dry no! No wonder, no matter how to change the outside of the radiator, the temperature can never come!)
Observe carefully and find that the chip in the middle is obviously higher than the surrounding, so there is no need to use a chip cover that is slid down! The bottom surface of the radiator is much larger than the cover area, and it is directly connected to the heat pipe. The effect is definitely stronger than the middle plus a two traffickers! To the graphics chip on the silicon grease, directly on the radiator, put back the machine, ha ha ha, everything is normal! All the temperatures are down! Graphics card machine temperature in more than 60 degrees! awesome! This broken machine can last for several years! To tell you the truth, if you still can't do it well, I'm ready to use a 1060 graphics card!
Summary: Ladies and gentlemen, if, after using your graphics card for a period of time, the temperature rises sharply, for example, more than 90 degrees, you should suspect that it should be the silicone grease in the video chip cover! Don't be afraid to start, sled off the lid, and then put the heat sink directly on the real chip of the video card. You will be glad to find that you can use it for several years! The province is not a small sum of money! (At the time of writing this article, I discovered a 2006 article, which was said to be a foreign expert, comparing the cooling effect of a CPU with a lid and a CPU with a lid removed! Obviously, the conclusion is that removing the lid has a better cooling effect. Good!) Ladies and gentlemen, because I checked on the Internet for a long time, I didn't find any articles like this to show you the real reason why the graphics card temperature is too high. So, I just took a few questions and gave you a summary. If you solve your problem, please give me praise!
Face Plate,electrical face plates,cat6 faceplate,face plates
NINGBO UONICORE ELECTRONICS CO., LTD , https://www.uonicore.com