Model NO.: HSYVP6A
Wire Core Material: Bare Copper Wire
Certification: CE, ISO, RoHS, CCC, UL, VDE
Model: Hsyvp6a
Brand: Hongan
Frequency: 4-500 MHz
Attenuation: 3.8-32.8 dB/100m
Phase Delay: 536-552 Ns/100m
Export Market: Europe,Middle East, South-East Asia,Africa etc.
Standards: IEC61156,ISO/IEC11801,ANSI/Tia/Eia-568-C,Yd/T1019
Certifications: UL, ISO,Ce,RoHS, Tlc, SGS
Operating Temperature: -20ºC--+60ºC
Trademark: Hongan
Transport Package: Box
Specification: Network Cable
Origin: China
HS Code: 8544491100
Model NO.: HSYVP6A
Wire Core Material: Bare Copper Wire
Certification: CE, ISO, RoHS, CCC, UL, VDE
Model: Hsyvp6a
Brand: Hongan
Frequency: 4-500 MHz
Attenuation: 3.8-32.8 dB/100m
Phase Delay: 536-552 Ns/100m
Export Market: Europe,Middle East, South-East Asia,Africa etc.
Standards: IEC61156,ISO/IEC11801,ANSI/Tia/Eia-568-C,Yd/T1019
Certifications: UL, ISO,Ce,RoHS, Tlc, SGS
Operating Temperature: -20ºC--+60ºC
Trademark: Hongan
Transport Package: Box
Specification: Network Cable
Origin: China
HS Code: 8544491100
Product Description:- Characteristics of product:
1.More bandwidth excess than 250MHz standard required;
2.Comply with ROHS standard;
3.Support 10-Gigabit Ethernet network transmission requirement;
4.The products of special outer sheath or purpose can be designed according to customer's demands.
- Applications:
1.10 Base-T4
2.100 Base-TX
3.100 Base-VG-ANYLAN
4.155 Mbps ATM
5.622 Mbps ATM
6.1000 Base-T
7.1000 Base-TX
8.10G Base-T
-Material instruction:
1.Conductor:23AWG Copper;
2.Insulation:Solid HDPE or Skin-Foam-Skin PE;
3.Sheath:Environment Friendly PVC or Flame Resistance PE or Low Smoke Zero Halogen Polyolefin(LSZHP);
-Physical Electrical Characteristics:
1.D.C resistance(max):7.5Ω/100m at 20ºC;
2.Mutual capacitance(max):5.6nF/100m;
3,Dielectric strength between conductors(min):2.5kv/2s;
4.Impedance:1-250MHz 100+/-15Ω;
5.Differential phase delay(max):45ns/100m;
6.Installation temperature:-20ºC-+60ºC;
7.Permitted bend radius:Over 8 times diameter of the cable.
Transmission Performance | ||||||||
Frequency(MHz) | Attenuation(Max)(dB/100m) | Next(Min)Â Â Â (dB/100m) | Psnext(Min)(dB/100m) | Elfext(Min)(dB/100m) | PSELFEXT(Min)(dB/100m) | RLÂ Â Â Â Â (Min)(dB) | Phase Velocity(Min)(m/s) | Phase delay(Max)(ns/100m) |
4 | 3.8 | 66.3 | 63.3 | 56 | 53 | 23 | 0.604c | 552 |
10 | 6.0 | 61 | 58 | 48 | 45 | 25 | 0.612c | 545 |
16 | 7.6 | 58 | 55 | 44 | 41 | 25 | 0.614c | 543 |
20 | 8.5 | 56 | 53 | 42 | 39 | 25 | 0.615c | 542 |
31.25 | 10.7 | 53 | 50 | 38 | 35 | 23.6 | 0.617c | 540 |
62.5 | 15.4 | 49 | 46 | 32 | 29 | 21.5 | 0.619c | 539 |
100 | 19.1 | 45.3 | 42.3 | 28 | 25 | 20.1 | 0.620c | 538 |
200 | 27.6 | 40.8 | 37.8 | 22 | 19 | 18 | 0.622c | 537 |
250 | 31.1 | 39.3 | 36.3 | 20 | 17 | 17.3 | 0.622c | 536 |
Advanced Production Line:


Â
Certifications:


Company Information
     Hongan Fiber Optical Cable Company was established in 1994 which was expanded in 1998,2001,2012 respectively. Advanced fiber optical cable lines and inspection equipments were imported from Switzerland,Finland,USA,Japan and other countries.The main products include:outerdoor fiber optical cable,indoor fiber optical cable,FTTH fiber optical cable, special fiber optical cable (include OPLC hybrid cable,ADSS fiber optical cable,under-water fiber optical cable,micro fiber optical cable, dry outdoor fiber optical cable.flexible armored indoor fiber optical cable,low temperature resistance fiber optical cable.high temperature resistance fiber optical cable etc.) Annual production capacity reaches 150,000 km.
      Hongan Optical Cable took the first lead to pass the ISO9001 quality system,ISO14001 environment management system.OHSAS18001 occupational health and safety management system, and its fiber optical cable meet the requirements of European CE.ROHS,Chinese TLC. The products are mainly used in China Mobile,China Telecom,China Broadcast,China Defense,Railway,Oil Fields and other communication operators ,also export to Europe, Middle East,South-East Asia,America,Africa etc.
Our Customers:


FAQ
-Q1:Are you a Factory or Trade Company?
A:We are cable manufacturer with 32's years experience,welcome to visit us in your free time.Thank you.
-Q2:Where is your factory loated? How can I visit there?
A:Our factory is loated in Weihai city,Shandong Province,China.Welcome all clients to visit our factory warmly!
-Q3:What kind of material we use?
A:High Quality PE,PVC,LSZH etc.
-Q4:Do you provide any sample?
A:Yes,we do pleasure to provide samples for your reviewing and testing.
Â
Hongan group, your faithful friend!     Â
Â
Â
- Characteristics of product:
1.More bandwidth excess than 250MHz standard required;
2.Comply with ROHS standard;
3.Support 10-Gigabit Ethernet network transmission requirement;
4.The products of special outer sheath or purpose can be designed according to customer's demands.
- Applications:
1.10 Base-T4
2.100 Base-TX
3.100 Base-VG-ANYLAN
4.155 Mbps ATM
5.622 Mbps ATM
6.1000 Base-T
7.1000 Base-TX
8.10G Base-T
-Material instruction:
1.Conductor:23AWG Copper;
2.Insulation:Solid HDPE or Skin-Foam-Skin PE;
3.Sheath:Environment Friendly PVC or Flame Resistance PE or Low Smoke Zero Halogen Polyolefin(LSZHP);
-Physical Electrical Characteristics:
1.D.C resistance(max):7.5Ω/100m at 20ºC;
2.Mutual capacitance(max):5.6nF/100m;
3,Dielectric strength between conductors(min):2.5kv/2s;
4.Impedance:1-250MHz 100+/-15Ω;
5.Differential phase delay(max):45ns/100m;
6.Installation temperature:-20ºC-+60ºC;
7.Permitted bend radius:Over 8 times diameter of the cable.
Transmission Performance | ||||||||
Frequency(MHz) | Attenuation(Max)(dB/100m) | Next(Min)Â Â Â (dB/100m) | Psnext(Min)(dB/100m) | Elfext(Min)(dB/100m) | PSELFEXT(Min)(dB/100m) | RLÂ Â Â Â Â (Min)(dB) | Phase Velocity(Min)(m/s) | Phase delay(Max)(ns/100m) |
4 | 3.8 | 66.3 | 63.3 | 56 | 53 | 23 | 0.604c | 552 |
10 | 6.0 | 61 | 58 | 48 | 45 | 25 | 0.612c | 545 |
16 | 7.6 | 58 | 55 | 44 | 41 | 25 | 0.614c | 543 |
20 | 8.5 | 56 | 53 | 42 | 39 | 25 | 0.615c | 542 |
31.25 | 10.7 | 53 | 50 | 38 | 35 | 23.6 | 0.617c | 540 |
62.5 | 15.4 | 49 | 46 | 32 | 29 | 21.5 | 0.619c | 539 |
100 | 19.1 | 45.3 | 42.3 | 28 | 25 | 20.1 | 0.620c | 538 |
200 | 27.6 | 40.8 | 37.8 | 22 | 19 | 18 | 0.622c | 537 |
250 | 31.1 | 39.3 | 36.3 | 20 | 17 | 17.3 | 0.622c | 536 |
Advanced Production Line:


Â
Certifications:


Company Information
     Hongan Fiber Optical Cable Company was established in 1994 which was expanded in 1998,2001,2012 respectively. Advanced fiber optical cable lines and inspection equipments were imported from Switzerland,Finland,USA,Japan and other countries.The main products include:outerdoor fiber optical cable,indoor fiber optical cable,FTTH fiber optical cable, special fiber optical cable (include OPLC hybrid cable,ADSS fiber optical cable,under-water fiber optical cable,micro fiber optical cable, dry outdoor fiber optical cable.flexible armored indoor fiber optical cable,low temperature resistance fiber optical cable.high temperature resistance fiber optical cable etc.) Annual production capacity reaches 150,000 km.
      Hongan Optical Cable took the first lead to pass the ISO9001 quality system,ISO14001 environment management system.OHSAS18001 occupational health and safety management system, and its fiber optical cable meet the requirements of European CE.ROHS,Chinese TLC. The products are mainly used in China Mobile,China Telecom,China Broadcast,China Defense,Railway,Oil Fields and other communication operators ,also export to Europe, Middle East,South-East Asia,America,Africa etc.
Our Customers:


FAQ
-Q1:Are you a Factory or Trade Company?
A:We are cable manufacturer with 32's years experience,welcome to visit us in your free time.Thank you.
-Q2:Where is your factory loated? How can I visit there?
A:Our factory is loated in Weihai city,Shandong Province,China.Welcome all clients to visit our factory warmly!
-Q3:What kind of material we use?
A:High Quality PE,PVC,LSZH etc.
-Q4:Do you provide any sample?
A:Yes,we do pleasure to provide samples for your reviewing and testing.
Â
Hongan group, your faithful friend!     Â
Â
Â
SKD T Shape Bulbs,LED T Shape Bulbs,T Shape Bulbs
Led Light Led Panel Co., Ltd. , http://www.yl-led.cn